Volumn 50, Issue 5, 2008, Pages 423-425

Cold Stress Dynamic Thermography for Evaluation of Vascular Disorders in Hand-Arm Vibration Syndrome

Author keywords

K maps; Occupational vibration; Raynaud's disease; Rewarming; Thermography; Vibration induced white finger

Indexed keywords

ARM; ARTICLE; COLD; FINGER; HAND; HAND ARM VIBRATION SYNDROME; HUMAN; METHODOLOGY; OCCUPATIONAL EXPOSURE; PATHOPHYSIOLOGY; SKIN TEMPERATURE; THERMOGRAPHY; VASCULAR DISEASE; VASCULARIZATION; VIBRATION; WARMING;

EID: 58149343850     PISSN: 13419145     EISSN: 13489585     Source Type: Journal    
DOI: 10.1539/joh.L7140     Document Type: Article
Times cited : (12)

References (12)
  • 1
    • 28444452223 scopus 로고    scopus 로고
    • Test battery for assessing vascular disturbances of fingers
    • Lindsell CL: Test battery for assessing vascular disturbances of fingers. Environ Health Prev Med 10, 341-350 (2005).
    • (2005) Environ Health Prev Med , vol.10 , pp. 341-350
    • Lindsell, C.L.1
  • 2
    • 28444473081 scopus 로고    scopus 로고
    • Different Conditions of Cold Water Immersion Test for Diagnosing Hand-Arm Vibration Syndrome
    • Laskar MS and Harada N: Different Conditions of Cold Water Immersion Test for Diagnosing Hand-Arm Vibration Syndrome. Environ Health Prev Med 10, 351-359 (2005).
    • (2005) Environ Health Prev Med , vol.10 , pp. 351-359
    • Laskar, M.S.1    Harada, N.2
  • 3
    • 58149377713 scopus 로고    scopus 로고
    • International Organization for Standardization. ISO 14835-1:2005 Mechanical vibration and shock -Cold provocation tests for the assessment of peripheral vascular function -Part 1: Measurement and evaluation of finger skin temperature. Geneve: ISO
    • International Organization for Standardization. ISO 14835-1:2005 Mechanical vibration and shock -Cold provocation tests for the assessment of peripheral vascular function -Part 1: Measurement and evaluation of finger skin temperature. Geneve: ISO, 2005.
    • (2005)
  • 4
    • 58149400585 scopus 로고    scopus 로고
    • International Organization for Standardization. ISO 14835-2:2005 Mechanical vibration and shock -Cold provocation tests for the assessment of peripheral vascular function -Part 2: Measurement and evaluation of finger systolic blood pressure. Geneve: ISO
    • International Organization for Standardization. ISO 14835-2:2005 Mechanical vibration and shock -Cold provocation tests for the assessment of peripheral vascular function -Part 2: Measurement and evaluation of finger systolic blood pressure. Geneve: ISO, 2005.
    • (2005)
  • 5
    • 0023615560 scopus 로고
    • Finger thermometry in the assessment of subjects with vibration-induced white finger
    • Bovenzi M: Finger thermometry in the assessment of subjects with vibration-induced white finger. Scand J Work Environ Health 13, 348-351 (1987).
    • (1987) Scand J Work Environ Health , vol.13 , pp. 348-351
    • Bovenzi, M.1
  • 6
    • 0036461264 scopus 로고    scopus 로고
    • Diagnostic aspects of vibration-induced white finger
    • Olsen N: Diagnostic aspects of vibration-induced white finger. Int Arch Occup Environ Health 75, 6-13 (2002).
    • (2002) Int Arch Occup Environ Health , vol.75 , pp. 6-13
    • Olsen, N.1
  • 7
    • 0036461058 scopus 로고    scopus 로고
    • Cold-stress tests involving finger skin temperature measurement for evaluation of vascular disorders in hand-arm vibration syndrome: review of the literature
    • Harada N: Cold-stress tests involving finger skin temperature measurement for evaluation of vascular disorders in hand-arm vibration syndrome: review of the literature. Int Arch Occup Environ Health 75, 14-19 (2002).
    • (2002) Int Arch Occup Environ Health , vol.75 , pp. 14-19
    • Harada, N.1
  • 8
    • 0036879776 scopus 로고    scopus 로고
    • Quantifying the relevance and stage of disease with the Tau image technique
    • Merla A, Di Donato L, Di Luzio S and Romani GL: Quantifying the relevance and stage of disease with the Tau image technique. IEEE Eng Med Biol Mag 21, 86-91 (2002).
    • (2002) IEEE Eng Med Biol Mag , vol.21 , pp. 86-91
    • Merla, A.1    Di Donato, L.2    Di Luzio, S.3    Romani, G.L.4
  • 10
    • 0025821870 scopus 로고
    • Pyroelectric vidicon thermography and cold challenge quantify the severity of Raynaud's phenomenon
    • Darton K and Black CM: Pyroelectric vidicon thermography and cold challenge quantify the severity of Raynaud's phenomenon. Br J Rheumatol 30, 190-195 (1991).
    • (1991) Br J Rheumatol , vol.30 , pp. 190-195
    • Darton, K.1    Black, C.M.2
  • 11
    • 0023616364 scopus 로고
    • Thermographic assessment of skin temperature during a cold provocation test
    • Dupuis H: Thermographic assessment of skin temperature during a cold provocation test. Scand J Work Environ Health 13, 352-355 (1987).
    • (1987) Scand J Work Environ Health , vol.13 , pp. 352-355
    • Dupuis, H.1
  • 12
    • 0029556463 scopus 로고
    • Clinical studies of the vibration syndrome using a cold stress test measuring finger temperature
    • Gautherie M: Clinical studies of the vibration syndrome using a cold stress test measuring finger temperature. Cent Eur J Public Health 3 (Suppl), 5-10 (1995).
    • (1995) Cent Eur J Public Health , vol.3 , pp. 5-10
    • Gautherie, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.