메뉴 건너뛰기




Volumn 45, Issue 6, 2008, Pages 350-355

Bell's phenomenon protects the tear film and ocular surface after frontalis suspension surgery for congenital ptosis

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BELL PHENOMENON; CHILD; CLINICAL ARTICLE; CONTROLLED STUDY; EYE MOVEMENT; EYE PROTECTION; EYE SURGERY; FASCIA LATA; FEMALE; FOLLOW UP; FRONTALIS SUSPENSION SURGERY; HUMAN; LAGOPHTHALMOS; MALE; PATIENT MONITORING; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD; PTOSIS; SCHIRMER TEST; SCHOOL CHILD; STAINING; TEAR FILM; ADOLESCENT; BELL PALSY; CORNEA; EXTRAOCULAR MUSCLE; LACRIMAL FLUID; PATHOPHYSIOLOGY; PHYSIOLOGY; SENSATION; TRANSPLANTATION;

EID: 58149314213     PISSN: 01913913     EISSN: None     Source Type: Journal    
DOI: 10.3928/01913913-20081101-17     Document Type: Article
Times cited : (20)

References (12)
  • 1
    • 0000358099 scopus 로고
    • Repair of ptosis using frontalis muscle and fascia lata
    • Crawford JS. Repair of ptosis using frontalis muscle and fascia lata. Trans Am Acad Ophthalmol Otolaryngol. 1956;60:672-678.
    • (1956) Trans Am Acad Ophthalmol Otolaryngol , vol.60 , pp. 672-678
    • Crawford, J.S.1
  • 2
    • 0023908087 scopus 로고
    • Congenital ptosis and complications of ptosis surgery
    • Beyer-Machule CK. Congenital ptosis and complications of ptosis surgery. Past Reconstr Surg. 1988;81:789-799.
    • (1988) Past Reconstr Surg , vol.81 , pp. 789-799
    • Beyer-Machule, C.K.1
  • 3
    • 0021853424 scopus 로고
    • Human eye movements associated with blinks and prolonged eyelid dosure
    • Collewijn H, van der Steen J, Steinman RM. Human eye movements associated with blinks and prolonged eyelid dosure. Neurophysiology. 1985;54:11-27.
    • (1985) Neurophysiology , vol.54 , pp. 11-27
    • Collewijn, H.1    van der Steen, J.2    Steinman, R.M.3
  • 4
    • 33746270510 scopus 로고
    • Inverse Bell's phenomenon as a protective mechanism
    • Gupta JS, Chatterjee A, Kumar K. Inverse Bell's phenomenon as a protective mechanism. Am J Ophthalmol. 1965;59:931-933.
    • (1965) Am J Ophthalmol , vol.59 , pp. 931-933
    • Gupta, J.S.1    Chatterjee, A.2    Kumar, K.3
  • 5
    • 33746316029 scopus 로고    scopus 로고
    • Inverse Bell's phenomenon observed following levator resection for blepharoptosis
    • Betharia SM, Sharma V. Inverse Bell's phenomenon observed following levator resection for blepharoptosis. Graefes Arch Clin Exp Ophthalmol. 2006;244:868-870.
    • (2006) Graefes Arch Clin Exp Ophthalmol , vol.244 , pp. 868-870
    • Betharia, S.M.1    Sharma, V.2
  • 7
    • 0030959759 scopus 로고    scopus 로고
    • Effect of beam variables on corneal sensitivity after excimer laser photorefractive keratectomy
    • Lawrenson JG, Corbett MC, O'Brat DP, Marshall J. Effect of beam variables on corneal sensitivity after excimer laser photorefractive keratectomy. Br J Ophthalmol. 1997;81:686-690.
    • (1997) Br J Ophthalmol , vol.81 , pp. 686-690
    • Lawrenson, J.G.1    Corbett, M.C.2    O'Brat, D.P.3    Marshall, J.4
  • 8
    • 0033662549 scopus 로고    scopus 로고
    • Correlation of the Schirmer 1 and fluorescein clearance tests with the severity of corneal epithelial and eyelid disease
    • Macri A, Pflugfelder SC. Correlation of the Schirmer 1 and fluorescein clearance tests with the severity of corneal epithelial and eyelid disease. Arch Ophthalmol. 2000;118:1632-1638.
    • (2000) Arch Ophthalmol , vol.118 , pp. 1632-1638
    • Macri, A.1    Pflugfelder, S.C.2
  • 9
    • 0028849933 scopus 로고
    • Report of the National Eye Institute/Industry workshop on Clinical Trials in Dry Eyes
    • Lemp MA. Report of the National Eye Institute/Industry workshop on Clinical Trials in Dry Eyes. CLAO J. 1995;21:221-232.
    • (1995) CLAO J , vol.21 , pp. 221-232
    • Lemp, M.A.1
  • 10
    • 11244250808 scopus 로고    scopus 로고
    • Eye complaints in the office environment: Precorneal tear film integrity influenced by eye blinking efficiency
    • Wolkoff R Nojgaard JK, Troiano P, Piccoli B. Eye complaints in the office environment: precorneal tear film integrity influenced by eye blinking efficiency. Occup Environ Med. 2005;62:4-12.
    • (2005) Occup Environ Med , vol.62 , pp. 4-12
    • Wolkoff, R.1    Nojgaard, J.K.2    Troiano, P.3    Piccoli, B.4
  • 11
    • 0021795370 scopus 로고
    • Physical chemistry of the normal and disordered tear film
    • Holly FJ. Physical chemistry of the normal and disordered tear film. Trans Ophthalmol Soc U K. 1985;104:374-380.
    • (1985) Trans Ophthalmol Soc U K , vol.104 , pp. 374-380
    • Holly, F.J.1
  • 12
    • 0031984088 scopus 로고    scopus 로고
    • Evaluation of subjective assessments and objective diagnostic tests for diagnosing tear-film disorders known to cause ocular irritation
    • Pflugfelder SC, Tseng SC, Sanabria O, et al. Evaluation of subjective assessments and objective diagnostic tests for diagnosing tear-film disorders known to cause ocular irritation. Cornea. 1998;17:38-56.
    • (1998) Cornea , vol.17 , pp. 38-56
    • Pflugfelder, S.C.1    Tseng, S.C.2    Sanabria, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.