메뉴 건너뛰기




Volumn 107, Issue 6, 2008, Pages 1936-1945

Preparation of the Dräger Fabius anesthesia machine for the malignant-hyperthermia susceptible patient

Author keywords

[No Author keywords available]

Indexed keywords

ABSORBENT; ACTIVATED CARBON; CARBON DIOXIDE; OXYGEN; SEVOFLURANE; ETHER DERIVATIVE; INHALATION ANESTHETIC AGENT;

EID: 58149310852     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/ane.0b013e31818874d3     Document Type: Article
Times cited : (34)

References (11)
  • 1
    • 0036207815 scopus 로고    scopus 로고
    • Preparation of the Siemens KION anesthetic machine for patients susceptible to malignant hyperthermia
    • Petroz GC, Lerman J. Preparation of the Siemens KION anesthetic machine for patients susceptible to malignant hyperthermia. Anesthesiology 2002;96:941-6
    • (2002) Anesthesiology , vol.96 , pp. 941-946
    • Petroz, G.C.1    Lerman, J.2
  • 2
    • 0037325967 scopus 로고    scopus 로고
    • Preparing a new generation anaesthetic machine for patients susceptible to malignant hyperthermia
    • Schö nell LH, Sims C, Bulsara M. Preparing a new generation anaesthetic machine for patients susceptible to malignant hyperthermia. Anaesth Intensive Care 2003;31:58-62
    • (2003) Anaesth Intensive Care , vol.31 , pp. 58-62
    • Schö nell, L.H.1    Sims, C.2    Bulsara, M.3
  • 3
    • 33750733976 scopus 로고    scopus 로고
    • Preparation of the Dräger Primus anesthetic machine for malignant hyperthermia-susceptible patients
    • Prinzhausen H, Crawford MW, O'Rourke J, Petroz GC. Preparation of the Dräger Primus anesthetic machine for malignant hyperthermia-susceptible patients. Can J Anaesth 2006;53: 885-90
    • (2006) Can J Anaesth , vol.53 , pp. 885-890
    • Prinzhausen, H.1    Crawford, M.W.2    O'Rourke, J.3    Petroz, G.C.4
  • 4
    • 33846590498 scopus 로고    scopus 로고
    • Accelerating the washout of inhalational anesthetics from the Dräger Primus anesthetic workstation
    • Crawford MW, Prinzhausen H, Petroz GC. Accelerating the washout of inhalational anesthetics from the Dräger Primus anesthetic workstation. Anesthesiology 2007;106:289 -94
    • (2007) Anesthesiology , vol.106 , pp. 289-294
    • Crawford, M.W.1    Prinzhausen, H.2    Petroz, G.C.3
  • 5
    • 67649239656 scopus 로고    scopus 로고
    • Drager Medical. Technical Data Fabius GS Operator's Instruction Manual. Chapter 12. Telford, PA: Drager Medical, 2004:142
    • Drager Medical. Technical Data Fabius GS Operator's Instruction Manual. Chapter 12. Telford, PA: Drager Medical, 2004:142
  • 6
    • 0008710477 scopus 로고
    • The solubility of halothane in rubber, soda lime and various plastics
    • Eger EI, Larson CP, Severinghaus JW. The solubility of halothane in rubber, soda lime and various plastics. Anesthesiology 1962;23:356-9
    • (1962) Anesthesiology , vol.23 , pp. 356-359
    • Eger, E.I.1    Larson, C.P.2    Severinghaus, J.W.3
  • 7
    • 0015026105 scopus 로고
    • Absorption of anesthetics by conductive rubber in breathing circuits
    • Lowe HI, Titel JH, Hagler KJ. Absorption of anesthetics by conductive rubber in breathing circuits. Anesthesiology 1971;34:283-9
    • (1971) Anesthesiology , vol.34 , pp. 283-289
    • Lowe, H.I.1    Titel, J.H.2    Hagler, K.J.3
  • 8
    • 0024786377 scopus 로고
    • Solubility of I-653, sevoflurane, isoflurane, and halothane in plastics and rubber composing a conventional anesthetic circuit
    • Targ AG, Yasuda N, Eger EI. Solubility of I-653, sevoflurane, isoflurane, and halothane in plastics and rubber composing a conventional anesthetic circuit. Anesth Analg 1989;69: 218 -25
    • (1989) Anesth Analg , vol.69 , pp. 218-225
    • Targ, A.G.1    Yasuda, N.2    Eger, E.I.3
  • 9
    • 0023706611 scopus 로고
    • Preparation of anesthesia machines for patients susceptible to malignant hyperthermia
    • Beebe JJ, Sessler DI. Preparation of anesthesia machines for patients susceptible to malignant hyperthermia. Anesthesiology 1988;69:395-400
    • (1988) Anesthesiology , vol.69 , pp. 395-400
    • Beebe, J.J.1    Sessler, D.I.2
  • 10
    • 0023924480 scopus 로고
    • Decontamination of halothane from anesthetic machines achieved by continuous flushing with oxygen
    • Ritchie PA, Cheshire MA, Pearce NH. Decontamination of halothane from anesthetic machines achieved by continuous flushing with oxygen. Br J Anaesth 1988;60:859-63
    • (1988) Br J Anaesth , vol.60 , pp. 859-863
    • Ritchie, P.A.1    Cheshire, M.A.2    Pearce, N.H.3
  • 11
    • 0024453735 scopus 로고
    • Malignant hyperthermia and the clean machine
    • McGraw TT, Keon TP. Malignant hyperthermia and the clean machine. Can J Anaesth 1989;36:530-2
    • (1989) Can J Anaesth , vol.36 , pp. 530-532
    • McGraw, T.T.1    Keon, T.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.