-
1
-
-
0029091465
-
Hemorheological and hemodynamic analysis of hypervolemic hemodilution therapy for cerebral vasospasm after aneurysmal subarachnoid hemorrhage
-
7660409
-
Mori K Arai H Nakajima K Tajima A Maeda M Hemorheological and hemodynamic analysis of hypervolemic hemodilution therapy for cerebral vasospasm after aneurysmal subarachnoid hemorrhage Stroke 1995, 26:1620-1626. 7660409
-
(1995)
Stroke
, vol.26
, pp. 1620-1626
-
-
Mori, K.1
Arai, H.2
Nakajima, K.3
Tajima, A.4
Maeda, M.5
-
2
-
-
33144480915
-
'Triple-H' therapy for cerebral vasospasm following subarachnoid hemorrhage
-
10.1385/NCC:4:1:068 16498198
-
Lee KH Lukovits T Friedman JA 'Triple-H' therapy for cerebral vasospasm following subarachnoid hemorrhage Neurocrit Care 2006, 4:68-76. 10.1385/ NCC:4:1:068 16498198
-
(2006)
Neurocrit Care
, vol.4
, pp. 68-76
-
-
Lee, K.H.1
Lukovits, T.2
Friedman, J.A.3
-
3
-
-
16644361957
-
Circulatory volume expansion therapy for aneurysmal subarachnoid haemorrhage
-
15494997
-
Rinkel G Feigin V Algra A van Gijn J Circulatory volume expansion therapy for aneurysmal subarachnoid haemorrhage Cochrane Database Syst Rev 2004, 4:CD000483. 15494997
-
(2004)
Cochrane Database Syst Rev
, vol.4
-
-
Rinkel, G.1
Feigin, V.2
Algra, A.3
van Gijn, J.4
-
4
-
-
0033806371
-
Accuracy and repeatability of blood volume measurement by pulse dye densitometry compared to the conventional method using 51Cr-labeled red blood cells
-
10.1007/s001340000618 11089762
-
Imai T Mitaka C Nosaka T Koike A Ohki S Isa Y Kunimoto F Accuracy and repeatability of blood volume measurement by pulse dye densitometry compared to the conventional method using 51Cr-labeled red blood cells Intensive Care Med 2000, 26:1343-1349. 10.1007/s001340000618 11089762
-
(2000)
Intensive Care Med
, vol.26
, pp. 1343-1349
-
-
Imai, T.1
Mitaka, C.2
Nosaka, T.3
Koike, A.4
Ohki, S.5
Isa, Y.6
Kunimoto, F.7
-
5
-
-
0037383589
-
Bedside monitoring of circulating blood volume after subarachnoid hemorrhage
-
10.1161/01.STR.0000064321.10700.63 12649506
-
Kasuya H Onda H Yoneyama T Sasaki T Hori T Bedside monitoring of circulating blood volume after subarachnoid hemorrhage Stroke 2003, 34:956-960. 10.1161/01.STR.0000064321.10700.63 12649506
-
(2003)
Stroke
, vol.34
, pp. 956-960
-
-
Kasuya, H.1
Onda, H.2
Yoneyama, T.3
Sasaki, T.4
Hori, T.5
-
6
-
-
32944456628
-
Blood volume measurement: The comparison of pulse dye densitometry and Dill and Costill's methods
-
16260003 10.1016/j.lfs.2005.07.025
-
Belin de Chantemèle E Gauquelin-Koch G Duvareille M Pellet N Gharib C Custaud MA Blood volume measurement: The comparison of pulse dye densitometry and Dill and Costill's methods Life Sci 2006, 78:1564-1569. 16260003 10.1016/j.lfs.2005.07.025
-
(2006)
Life Sci
, vol.78
, pp. 1564-1569
-
-
Belin de Chantemèle, E.1
Gauquelin-Koch, G.2
Duvareille, M.3
Pellet, N.4
Gharib, C.5
Custaud, M.A.6
-
7
-
-
0031880504
-
Measurement of blood volume using indocyanine green measured with pulse-spectrophotometry: Its reproducibility and reliability
-
10.1097/00003246-199808000-00036 9710108
-
He YL Tanigami H Ueyama H Mashimo T Yoshiya I Measurement of blood volume using indocyanine green measured with pulse-spectrophotometry: its reproducibility and reliability Crit Care Med 1998, 26:1446-1451. 10.1097/00003246-199808000-00036 9710108
-
(1998)
Crit Care Med
, vol.26
, pp. 1446-1451
-
-
He, Y.L.1
Tanigami, H.2
Ueyama, H.3
Mashimo, T.4
Yoshiya, I.5
-
8
-
-
0033966469
-
Measurement of blood volume in surgical and intensive care practice
-
10743457
-
Jones JG Wardrop CA Measurement of blood volume in surgical and intensive care practice Br J Anaesth 2000, 84:226-235. 10743457
-
(2000)
Br J Anaesth
, vol.84
, pp. 226-235
-
-
Jones, J.G.1
Wardrop, C.A.2
-
9
-
-
23144438355
-
Determination of the standard value of circulating blood volume during anesthesia using pulse dye-densitometry: A multicenter study in Japan
-
10.1007/s00540-005-0320-6 16032445
-
Iijima T Ueyama H Oi Y Fukuda I Ishihara H Kohase H Kotake Y Koyama K Miyao H Kobayashi N Determination of the standard value of circulating blood volume during anesthesia using pulse dye-densitometry: A multicenter study in Japan J Anesth 2005, 19:193-198. 10.1007/ s00540-005-0320-6 16032445
-
(2005)
J Anesth
, vol.19
, pp. 193-198
-
-
Iijima, T.1
Ueyama, H.2
Oi, Y.3
Fukuda, I.4
Ishihara, H.5
Kohase, H.6
Kotake, Y.7
Koyama, K.8
Miyao, H.9
Kobayashi, N.10
-
10
-
-
65249128245
-
-
VassarStats http://faculty.vassar.edu/lowry/VassarStats.html
-
VassarStats
-
-
-
11
-
-
33747626262
-
Physical assessment: Whose role is it anyway?
-
10.1111/j.1362-1017.2006.00161.x 16869522
-
West SL Physical assessment: Whose role is it anyway? Nurs Crit Care 2006, 11:161-167. 10.1111/j.1362-1017.2006.00161.x 16869522
-
(2006)
Nurs Crit Care
, vol.11
, pp. 161-167
-
-
West, S.L.1
-
12
-
-
0030700514
-
Physiology and pathophysiology of blood volume regulation
-
10.1016/S0955-3886(97)00040-4 10175155
-
Isbister JP Physiology and pathophysiology of blood volume regulation Transfus Sci 1997, 18:409-423. 10.1016/S0955-3886(97)00040-4 10175155
-
(1997)
Transfus Sci
, vol.18
, pp. 409-423
-
-
Isbister, J.P.1
-
13
-
-
51449110652
-
Fluid balance and blood volume measurement after aneurysmal subarachnoid hemorrhage
-
10.1007/s12028-007-9043-x 18172784
-
Hoff RG Dijk GWv Algra A Kalkman CJ Rinkel GJE Fluid balance and blood volume measurement after aneurysmal subarachnoid hemorrhage Neurocrit Care 2008, 8:391-397. 10.1007/s12028-007-9043-x 18172784
-
(2008)
Neurocrit Care
, vol.8
, pp. 391-397
-
-
Hoff, R.G.1
Dijk, G.Wv.2
Algra, A.3
Kalkman, C.J.4
Rinkel, G.J.E.5
-
14
-
-
0034985612
-
Clinical evaluation of circulating blood volume in critically ill patients: Contribution of a clinical scoring system
-
10.1093/bja/86.6.754 11573580
-
Stephan F Flahault A Dieudonne N Hollande J Paillard F Bonnet F Clinical evaluation of circulating blood volume in critically ill patients: contribution of a clinical scoring system Br J Anaesth 2001, 86:754-762. 10.1093/bja/86.6.754 11573580
-
(2001)
Br J Anaesth
, vol.86
, pp. 754-762
-
-
Stephan, F.1
Flahault, A.2
Dieudonne, N.3
Hollande, J.4
Paillard, F.5
Bonnet, F.6
-
15
-
-
34447126479
-
Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients?
-
10.1007/s00134-007-0644-9 17508201
-
Soubrier S Saulnier F Hubert H Delour P Lenci H Onimus T Nseir S Durocher A Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients? Intensive Care Med 2007, 33:1117-1124. 10.1007/s00134-007-0644-9 17508201
-
(2007)
Intensive Care Med
, vol.33
, pp. 1117-1124
-
-
Soubrier, S.1
Saulnier, F.2
Hubert, H.3
Delour, P.4
Lenci, H.5
Onimus, T.6
Nseir, S.7
Durocher, A.8
-
16
-
-
34347222567
-
Hemodynamic monitoring in shock and implications for management
-
10.1007/s00134-007-0531-4 17285286
-
Antonelli M Levy M Andrews PJD Chastre J Hudson LD Manthous C Meduri GU Moreno RP Putensen C Stewart T Torres A Hemodynamic monitoring in shock and implications for management Intensive Care Med 2007, 33:575-590. 10.1007/s00134-007-0531-4 17285286
-
(2007)
Intensive Care Med
, vol.33
, pp. 575-590
-
-
Antonelli, M.1
Levy, M.2
Andrews, P.J.D.3
Chastre, J.4
Hudson, L.D.5
Manthous, C.6
Meduri, G.U.7
Moreno, R.P.8
Putensen, C.9
Stewart, T.10
Torres, A.11
|