메뉴 건너뛰기




Volumn 19, Issue 11, 2008, Pages

Enhancing the measurement accuracy of a cavity-enhanced fiber chemical sensor by an adaptive filter

Author keywords

Adaptive filter; Amplified spontaneous emission (ASE) noise; Cavity enhanced fiber chemical sensor; Measurement accuracy

Indexed keywords

ACETYLENE; ADAPTIVE FILTERING; ADAPTIVE FILTERS; BANDPASS FILTERS; CHEMICAL SENSORS; FIBER AMPLIFIERS; FIBERS; LIGHT MEASUREMENT; LIGHTING; SPONTANEOUS EMISSION;

EID: 58149292025     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/19/11/115203     Document Type: Article
Times cited : (20)

References (17)
  • 1
    • 0036742174 scopus 로고    scopus 로고
    • Novel intracavity sensing network based on mode-locked fiber laser
    • Zhang Y et al 2002 Novel intracavity sensing network based on mode-locked fiber laser IEEE Photonics Technol. Lett. 14 1336-8
    • (2002) IEEE Photonics Technol. Lett. , vol.14 , Issue.9 , pp. 1336-1338
    • Zhang, Y.1    Al, E.2
  • 2
    • 1642493887 scopus 로고    scopus 로고
    • Evanescent field absorption in a passive optical fiber resonator using continuous-wave cavity ring-down spectroscopy
    • Tarsa P B, Rabinowitz P and Lehmann K K 2004 Evanescent field absorption in a passive optical fiber resonator using continuous-wave cavity ring-down spectroscopy Chem. Phys. Lett. 383 297-303
    • (2004) Chem. Phys. Lett. , vol.383 , Issue.3-4 , pp. 297-303
    • Tarsa, P.B.1    Rabinowitz, P.2    Lehmann, K.K.3
  • 3
    • 0345377010 scopus 로고    scopus 로고
    • Fiber-loop ring-down spectroscopy: A sensitive absorption technique for small liquid samples
    • Tong Z, Jakubinek M, Wright A, Gillies A and Loock H P 2003 Fiber-loop ring-down spectroscopy: a sensitive absorption technique for small liquid samples Rev. Sci. Instrum. 74 4818-26
    • (2003) Rev. Sci. Instrum. , vol.74 , Issue.11 , pp. 4818-4826
    • Tong, Z.1    Jakubinek, M.2    Wright, A.3    Gillies, A.4    Loock, H.P.5
  • 4
    • 2942715162 scopus 로고    scopus 로고
    • Cavity-enhanced spectroscopy in fiber cavities
    • Stewart G, Atherton K and Culshaw B 2004 Cavity-enhanced spectroscopy in fiber cavities Opt. Lett. 29 442-4
    • (2004) Opt. Lett. , vol.29 , Issue.5 , pp. 442-444
    • Stewart, G.1    Atherton, K.2    Culshaw, B.3
  • 5
    • 0141921846 scopus 로고    scopus 로고
    • Fiber-optic cavity sensing of hydrogen diffusion
    • Vogler D E, Muller M G and Sigrist M W 2003 Fiber-optic cavity sensing of hydrogen diffusion Appl. Opt. 42 5413-7
    • (2003) Appl. Opt. , vol.42 , Issue.27 , pp. 5413-5417
    • Vogler, D.E.1    Muller, M.G.2    Sigrist, M.W.3
  • 7
    • 2942607454 scopus 로고    scopus 로고
    • Cavity ringdown strain gauge
    • Tarsa W P et al 2004 Cavity ringdown strain gauge Opt. Lett. 29 1339-41
    • (2004) Opt. Lett. , vol.29 , Issue.12 , pp. 1339-1341
    • Tarsa, W.P.1    Al, E.2
  • 8
    • 1242265186 scopus 로고    scopus 로고
    • Fiber ringdown pressure sensors
    • Wang C and Scherrer S T 2004 Fiber ringdown pressure sensors Opt. Lett. 29 352-4
    • (2004) Opt. Lett. , vol.29 , Issue.4 , pp. 352-354
    • Wang, C.1    Scherrer, S.T.2
  • 9
    • 24744443274 scopus 로고    scopus 로고
    • Fiber ringdown temperature sensor
    • Wang C 2005 Fiber ringdown temperature sensor Opt. Eng. Lett. 44 030503
    • (2005) Opt. Eng. Lett. , vol.44 , pp. 030503
    • Wang, C.1
  • 10
    • 33745485098 scopus 로고    scopus 로고
    • An alternative method to develop fibre grating temperature sensors using the fibre loop ringdown scheme
    • Wang C and Mbi A 2006 An alternative method to develop fibre grating temperature sensors using the fibre loop ringdown scheme Meas. Sci. Technol. 17 1741-51
    • (2006) Meas. Sci. Technol. , vol.17 , Issue.7 , pp. 1741-1751
    • Wang, C.1    Mbi, A.2
  • 12
    • 0035395493 scopus 로고    scopus 로고
    • An investigation of an optical fiber amplifier loop for intra-cavity and ring down cavity loss measurements
    • Stewart G, Atherton K, Yu H B and Culshaw B 2001 An investigation of an optical fiber amplifier loop for intra-cavity and ring down cavity loss measurements Meas. Sci. Technol. 12 843-9
    • (2001) Meas. Sci. Technol. , vol.12 , Issue.7 , pp. 843-849
    • Stewart, G.1    Atherton, K.2    Yu, H.B.3    Culshaw, B.4
  • 13
    • 84963690259 scopus 로고    scopus 로고
    • Cavity ring-down in a fiber amplifier loop and combination with wavelength modulation spectroscopy
    • Atherton K, Stewart G and Culshaw B 2002 Cavity ring-down in a fiber amplifier loop and combination with wavelength modulation spectroscopy Optical Fiber Sensors Conf. Technical Digest vol 1 pp 581-4
    • (2002) Optical Fiber Sensors Conf. Technical Digest , vol.1 , pp. 581-584
    • Atherton, K.1    Stewart, G.2    Culshaw, B.3
  • 14
    • 33746288954 scopus 로고    scopus 로고
    • Improving the measurement accuracy of the CRD fiber amplified loop gas sensing system by using a digital LMS adaptive filter
    • Ni N and Chan C C 2006 Improving the measurement accuracy of the CRD fiber amplified loop gas sensing system by using a digital LMS adaptive filter Meas. Sci. Technol. 17 2349-54
    • (2006) Meas. Sci. Technol. , vol.17 , Issue.8 , pp. 2349-2354
    • Ni, N.1    Chan, C.C.2
  • 16
    • 33748038454 scopus 로고    scopus 로고
    • Improving the measurement accuracy of hydrogen cyanide sensor by using DSP technique
    • Ni N and Chan C C 2006 Improving the measurement accuracy of hydrogen cyanide sensor by using DSP technique Adv. Mater. Optoelectron. 8, 4 1613-5
    • (2006) Adv. Mater. Optoelectron. , vol.8 , pp. 1613-1615
    • Ni, N.1    Chan, C.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.