메뉴 건너뛰기




Volumn 55, Issue 12, 2008, Pages 2768-2771

Taser blunt probe dart-to-heart distance causing ventricular fibrillation in pigs

Author keywords

Electrical safety; Electromuscular incapacitating device; Fibrillation; Safety; Stun gun; Taser; Ventricular fibrillation (VF)

Indexed keywords

ELECTRICAL SAFETY; ELECTROMUSCULAR INCAPACITATING DEVICE; FIBRILLATION; SAFETY; STUN GUN; TASER; VENTRICULAR FIBRILLATION (VF);

EID: 58149267838     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2008.2002154     Document Type: Article
Times cited : (34)

References (10)
  • 1
    • 58149219434 scopus 로고    scopus 로고
    • Online, Available
    • Amnesty International [Online]. Available: http://news.amnesty.org/index/ ENGAMR510392006
  • 2
    • 58149246568 scopus 로고    scopus 로고
    • D. Manojlovic, C. Hall, D. Laur, S. Goodkey, C. Lawrence, R. Shaw, S. St-Amour, A. Neufeld, and S. Palmer, Review of conducted energy devices, Canadian Assoc. Chiefs Police, Ottawa, ON, Canada, Tech. Rep. TR-01-2006, 2005 [Online]. Available: http://www2.taser.com/research/science/ documents/canada%20safety%20report.pdf
    • D. Manojlovic, C. Hall, D. Laur, S. Goodkey, C. Lawrence, R. Shaw, S. St-Amour, A. Neufeld, and S. Palmer, "Review of conducted energy devices," Canadian Assoc. Chiefs Police, Ottawa, ON, Canada, Tech. Rep. TR-01-2006, 2005 [Online]. Available: http://www2.taser.com/research/science/ documents/canada%20safety%20report.pdf
  • 3
    • 36949009654 scopus 로고    scopus 로고
    • Electromagnetic modelling of current flow in the heart from TASER devices and the risk of cardiac dysrhythmias
    • S. J. Holden, R. D. Sheridan, T. J. Coffey, R. A. Scaramuzza, and P. Diamantopoulos, "Electromagnetic modelling of current flow in the heart from TASER devices and the risk of cardiac dysrhythmias," Phys. Med. Biol., vol. 52, pp. 7193-7209, 2007.
    • (2007) Phys. Med. Biol , vol.52 , pp. 7193-7209
    • Holden, S.J.1    Sheridan, R.D.2    Coffey, T.J.3    Scaramuzza, R.A.4    Diamantopoulos, P.5
  • 4
    • 2442696355 scopus 로고    scopus 로고
    • The small heart and the critical mass for ventricular fibrillation
    • Jan.-Feb
    • L. A. Geddes, "The small heart and the critical mass for ventricular fibrillation," IEEE Eng. Med. Biol. Mag., vol. 23, no. 1, pp. 196-197, Jan.-Feb. 2004.
    • (2004) IEEE Eng. Med. Biol. Mag , vol.23 , Issue.1 , pp. 196-197
    • Geddes, L.A.1
  • 6
    • 0344237417 scopus 로고    scopus 로고
    • Frequency dependence of the cardiac threshold to alternating current between 10 Hz and 160 Hz
    • R. A. Malkin and A. de-J. Curry, "Frequency dependence of the cardiac threshold to alternating current between 10 Hz and 160 Hz," Med. Biol. Eng. Comput., vol. 41, pp. 640-645, 2003.
    • (2003) Med. Biol. Eng. Comput , vol.41 , pp. 640-645
    • Malkin, R.A.1    Curry, A.D.E.-J.2
  • 8
    • 0017101126 scopus 로고
    • 60-Hz ventricular fibrillation and pump failure thresholds versus electrode
    • Jan
    • O. Z. Roy, J. R. Scott, and G. C. Park, "60-Hz ventricular fibrillation and pump failure thresholds versus electrode," IEEE Trans. Biomed. Eng., vol. BME-23, no. 1, pp. 45-48, Jan. 1976.
    • (1976) IEEE Trans. Biomed. Eng , vol.BME-23 , Issue.1 , pp. 45-48
    • Roy, O.Z.1    Scott, J.R.2    Park, G.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.