메뉴 건너뛰기




Volumn 26, Issue 1, 2009, Pages 114-117

Platypnea-orthodeoxia syndrome associated with patent foramen ovale and aortic ectasia

Author keywords

Color Doppler transesophageal echocardiography; Congenital heart defects; Contrast microbubbles; Orthodeoxia; Patent foramen ovale

Indexed keywords

ADULT; AORTA DISEASE; AORTA VALVE REGURGITATION; AORTIC ECTASIA; ARTICLE; BLOOD PRESSURE; CLINICAL FEATURE; DYSPNEA; ELECTROCARDIOGRAPHY; HEART CATHETERIZATION; HUMAN; MALE; PATENT FORAMEN OVALE; PLATYPNEA ORTHODEOXIA SYNDROME; PRIORITY JOURNAL;

EID: 58149202524     PISSN: 07422822     EISSN: 15408175     Source Type: Journal    
DOI: 10.1111/j.1540-8175.2008.00780.x     Document Type: Article
Times cited : (11)

References (10)
  • 1
    • 0000070636 scopus 로고
    • Reflect orthostatic dyspnea associated with pulmonary hypotension
    • Burchell H, Hemholtz HJ, EHW : Reflect orthostatic dyspnea associated with pulmonary hypotension. Am J Physiol 1949 159 : 563 564.
    • (1949) Am J Physiol , vol.159 , pp. 563-564
    • Burchell, H.1    Hemholtz, H.J.E.H.W.2
  • 2
    • 0037396403 scopus 로고    scopus 로고
    • Platypnea-orthodeoxia in a patient with ostium primum atrial septal defect with normal right heart pressures
    • Patel AD, Abo-Auda WS, Nekkanti R, et al : Platypnea-orthodeoxia in a patient with ostium primum atrial septal defect with normal right heart pressures. Echocardiography 2003 20 : 299 303.
    • (2003) Echocardiography , vol.20 , pp. 299-303
    • Patel, A.D.1    Abo-Auda, W.S.2    Nekkanti, R.3
  • 3
    • 0033994080 scopus 로고    scopus 로고
    • Atrial right-to-left shunting causing severe hypoxaemia despite normal right-sided pressures. Report of 11 consecutive cases corrected by percutaneous closure
    • Godart F, Rey C, Prat A, et al : Atrial right-to-left shunting causing severe hypoxaemia despite normal right-sided pressures. Report of 11 consecutive cases corrected by percutaneous closure. Eur Heart J 2000 21 : 483 489.
    • (2000) Eur Heart J , vol.21 , pp. 483-489
    • Godart, F.1    Rey, C.2    Prat, A.3
  • 4
    • 0037065994 scopus 로고    scopus 로고
    • Mechanisms of platypnea-orthodeoxia: What causes water to flow uphill?
    • Cheng TO : Mechanisms of platypnea-orthodeoxia: What causes water to flow uphill? Circulation 2002 105 : e47.
    • (2002) Circulation , vol.105
    • Cheng, T.O.1
  • 5
    • 0037422526 scopus 로고    scopus 로고
    • Contemporary management of patent foramen ovale
    • Meier B, Lock JE : Contemporary management of patent foramen ovale. Circulation 2003 107 : 5 9.
    • (2003) Circulation , vol.107 , pp. 5-9
    • Meier, B.1    Lock, J.E.2
  • 6
    • 0033890827 scopus 로고    scopus 로고
    • Platypnea-orthodeoxia syndrome related to an aortic aneurysm combined with an aneurysm of the atrial septum
    • Faller M, Kessler R, Chaouat A, et al : Platypnea-orthodeoxia syndrome related to an aortic aneurysm combined with an aneurysm of the atrial septum. Chest 2000 118 : 553 557.
    • (2000) Chest , vol.118 , pp. 553-557
    • Faller, M.1    Kessler, R.2    Chaouat, A.3
  • 7
    • 33746572045 scopus 로고    scopus 로고
    • Protocol for optimal detection and exclusion of a patent foramen ovale using transthoracic echocardiography with agitated saline microbubbles
    • Attaran RR, Ata I, Kudithipudi V, et al : Protocol for optimal detection and exclusion of a patent foramen ovale using transthoracic echocardiography with agitated saline microbubbles. Echocardiography 2006 23 : 616 622.
    • (2006) Echocardiography , vol.23 , pp. 616-622
    • Attaran, R.R.1    Ata, I.2    Kudithipudi, V.3
  • 8
    • 0027692180 scopus 로고
    • Diagnostic value of transesophageal echocardiography in platypnea
    • Herregods MC, Timmermans C, Frans E, et al : Diagnostic value of transesophageal echocardiography in platypnea. J Am Soc Echocardiogr 1993 6 : 624 627.
    • (1993) J Am Soc Echocardiogr , vol.6 , pp. 624-627
    • Herregods, M.C.1    Timmermans, C.2    Frans, E.3
  • 9
    • 0034850292 scopus 로고    scopus 로고
    • Platypnea-orthodeoxia: Management by transcatheter buttoned device implantation
    • Rao PS, Palacios IF, Bach RG, et al : Platypnea-orthodeoxia: Management by transcatheter buttoned device implantation. Catheter Cardiovasc Interv 2001 54 : 77 82.
    • (2001) Catheter Cardiovasc Interv , vol.54 , pp. 77-82
    • Rao, P.S.1    Palacios, I.F.2    Bach, R.G.3
  • 10
    • 19944390986 scopus 로고    scopus 로고
    • Transcatheter closure of patent foramen ovale in patients with platypnea-orthodeoxia: Results of a multicentric French registry
    • Guerin P, Lambert V, Godart F, et al : Transcatheter closure of patent foramen ovale in patients with platypnea-orthodeoxia: Results of a multicentric French registry. Cardiovasc Intervent Radiol 2005 28 : 164 168.
    • (2005) Cardiovasc Intervent Radiol , vol.28 , pp. 164-168
    • Guerin, P.1    Lambert, V.2    Godart, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.