메뉴 건너뛰기




Volumn 15, Issue 6, 2008, Pages 643-654

Effects of stent design and atherosclerotic plaque composition on arterial wall biomechanics

Author keywords

Artery wall model; Atherosclerotic plaque; Experimental model; Finite element analysis; Restenosis; Stent; Stent design; Stress

Indexed keywords

ARTERIAL STIFFNESS; ARTERY DIAMETER; ARTERY OCCLUSION; ARTERY WALL; ARTICLE; ATHEROSCLEROTIC PLAQUE; BIOMECHANICS; CONTROLLED STUDY; EQUIPMENT DESIGN; INTERMETHOD COMPARISON; PRIORITY JOURNAL; SIMULATION; STENT; VASCULAR PATENCY;

EID: 58149202342     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1583/08-2443.1     Document Type: Article
Times cited : (46)

References (29)
  • 1
    • 0032499021 scopus 로고    scopus 로고
    • Pathobiologic responses to stenting
    • Edelman ER, Rogers C. Pathobiologic responses to stenting. Am J Cardiol. 1998;81: 4E-6E.
    • (1998) Am J Cardiol , vol.81
    • Edelman, E.R.1    Rogers, C.2
  • 2
    • 0035178080 scopus 로고    scopus 로고
    • Restenosis after coronary placement of various stent types
    • Kastrati A, Mehilli J, Dirschinger J, et al. Restenosis after coronary placement of various stent types. Am J Cardiol. 2001;87:34-39.
    • (2001) Am J Cardiol , vol.87 , pp. 34-39
    • Kastrati, A.1    Mehilli, J.2    Dirschinger, J.3
  • 4
    • 33745233024 scopus 로고    scopus 로고
    • Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk
    • Joner M, Finn AV, Farb A, et al. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol. 2006;48:193-202.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 193-202
    • Joner, M.1    Finn, A.V.2    Farb, A.3
  • 5
    • 33845387555 scopus 로고    scopus 로고
    • Drug-eluting and bare nitinol stents for the treatment of atherosclerotic lesions in the superficial femoral artery: Long-term results from the SIROCCO trial
    • Duda SH, Bosiers M, Lammer J, et al. Drug-eluting and bare nitinol stents for the treatment of atherosclerotic lesions in the superficial femoral artery: long-term results from the SIROCCO trial. J Endovasc Ther. 2006;13: 701-710.
    • (2006) J Endovasc Ther , vol.13 , pp. 701-710
    • Duda, S.H.1    Bosiers, M.2    Lammer, J.3
  • 6
    • 16344362656 scopus 로고    scopus 로고
    • Changes in the mechanical environment of stenotic arteries during interaction with stents: Computational assessment of parametric stent designs
    • Holzapfel GA, Stadler M, Gasser TC. Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs. J Biomech Eng. 2005;127:166-180.
    • (2005) J Biomech Eng , vol.127 , pp. 166-180
    • Holzapfel, G.A.1    Stadler, M.2    Gasser, T.C.3
  • 7
    • 35548954226 scopus 로고    scopus 로고
    • A numerical model to study the interaction of vascular stents with human atherosclerotic lesions
    • Kiousis DE, Gasser TC, Holzapfel GA. A numerical model to study the interaction of vascular stents with human atherosclerotic lesions. Ann Biomed Eng. 2007;35:1857-1869.
    • (2007) Ann Biomed Eng , vol.35 , pp. 1857-1869
    • Kiousis, D.E.1    Gasser, T.C.2    Holzapfel, G.A.3
  • 9
    • 20444475661 scopus 로고    scopus 로고
    • Cardiovascular stent design and vessel stresses: A finite element analysis
    • Lally C, Dolan F, Prendergast PJ. Cardiovascular stent design and vessel stresses: a finite element analysis. J Biomech. 2005;38: 1574-1581.
    • (2005) J Biomech , vol.38 , pp. 1574-1581
    • Lally, C.1    Dolan, F.2    Prendergast, P.J.3
  • 10
    • 33750378236 scopus 로고    scopus 로고
    • Effects of stent design parameters on normal artery wall mechanics
    • Bedoya J, Meyer CA, Timmins LH, et al. Effects of stent design parameters on normal artery wall mechanics. J Biomech Eng. 2006;128: 757-765.
    • (2006) J Biomech Eng , vol.128 , pp. 757-765
    • Bedoya, J.1    Meyer, C.A.2    Timmins, L.H.3
  • 11
    • 11144265911 scopus 로고    scopus 로고
    • Anisotropic mechanical properties of tissue components in human atherosclerotic plaques
    • Holzapfel GA, Sommer G, Regitnig P. Anisotropic mechanical properties of tissue components in human atherosclerotic plaques. J Biomech Eng. 2004;126:657-665.
    • (2004) J Biomech Eng , vol.126 , pp. 657-665
    • Holzapfel, G.A.1    Sommer, G.2    Regitnig, P.3
  • 12
    • 0035091438 scopus 로고    scopus 로고
    • Compressive stress-relaxation of human atherosclerotic plaque
    • Salunke NV, Topoleski LD, Humphrey JD, et al. Compressive stress-relaxation of human atherosclerotic plaque. J Biomed Mater Res. 2001;55:236-241.
    • (2001) J Biomed Mater Res , vol.55 , pp. 236-241
    • Salunke, N.V.1    Topoleski, L.D.2    Humphrey, J.D.3
  • 13
    • 0027690195 scopus 로고
    • Experimental approaches on measuring the mechanical properties and constitutive laws of arterial walls
    • Hayashi K. Experimental approaches on measuring the mechanical properties and constitutive laws of arterial walls. J Biomech Eng. 1993;115:481-488.
    • (1993) J Biomech Eng , vol.115 , pp. 481-488
    • Hayashi, K.1
  • 14
    • 2342660237 scopus 로고    scopus 로고
    • Reporting standards for carotid artery angioplasty and stent placement
    • Higashida RT, Meyers PM, Phatouros CC, et al. Reporting standards for carotid artery angioplasty and stent placement. Stroke. 2004;35: e112-134.
    • (2004) Stroke , vol.35
    • Higashida, R.T.1    Meyers, P.M.2    Phatouros, C.C.3
  • 15
    • 0023243605 scopus 로고
    • Vessel, plaque, and lumen morphology after transluminal balloon angioplasty. Quantitative study in distended human arteries
    • Lyon RT, Zarins CK, Lu CT, et al. Vessel, plaque, and lumen morphology after transluminal balloon angioplasty. Quantitative study in distended human arteries. Arteriosclerosis. 1987;7:306-314.
    • (1987) Arteriosclerosis , vol.7 , pp. 306-314
    • Lyon, R.T.1    Zarins, C.K.2    Lu, C.T.3
  • 16
    • 34247607878 scopus 로고    scopus 로고
    • Stented artery biomechanics and device design optimization
    • Timmins LH, Moreno MR, Meyer CA, et al. Stented artery biomechanics and device design optimization. Med Biol Eng Comput. 2007;45:505-513.
    • (2007) Med Biol Eng Comput , vol.45 , pp. 505-513
    • Timmins, L.H.1    Moreno, M.R.2    Meyer, C.A.3
  • 17
    • 10444282238 scopus 로고    scopus 로고
    • Stainless and shape memory alloy coronary stents: A computational study on the interaction with the vascular wall
    • Migliavacca F, Petrini L, Massarotti P, et al. Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall. Biomech Model Mechanobiol. 2004;2:205-217.
    • (2004) Biomech Model Mechanobiol , vol.2 , pp. 205-217
    • Migliavacca, F.1    Petrini, L.2    Massarotti, P.3
  • 18
    • 0030087597 scopus 로고    scopus 로고
    • Stress and strain distribution in hypertensive and normotensive rat aorta considering residual strain
    • Matsumoto T, Hayashi K. Stress and strain distribution in hypertensive and normotensive rat aorta considering residual strain. J Biomech Eng. 1996;118:62-73.
    • (1996) J Biomech Eng , vol.118 , pp. 62-73
    • Matsumoto, T.1    Hayashi, K.2
  • 19
    • 0035017644 scopus 로고    scopus 로고
    • Cyclic stretch induces the expression of vascular endothelial growth factor in vascular smooth muscle cells
    • Smith JD, Davies N, Willis AI, et al. Cyclic stretch induces the expression of vascular endothelial growth factor in vascular smooth muscle cells. Endothelium. 2001;8:41-48.
    • (2001) Endothelium , vol.8 , pp. 41-48
    • Smith, J.D.1    Davies, N.2    Willis, A.I.3
  • 20
    • 0037172986 scopus 로고    scopus 로고
    • Morphological predictors of restenosis after coronary stenting in humans
    • Farb A, Weber DK, Kolodgie FD, et al. Morphological predictors of restenosis after coronary stenting in humans. Circulation. 2002;105:2974-2980.
    • (2002) Circulation , vol.105 , pp. 2974-2980
    • Farb, A.1    Weber, D.K.2    Kolodgie, F.D.3
  • 21
    • 0036073194 scopus 로고    scopus 로고
    • Rat carotid artery dilation by PTCA balloon catheter induces neointima formation in presence of IEL rupture
    • Indolfi C, Torella D, Coppola C, et al. Rat carotid artery dilation by PTCA balloon catheter induces neointima formation in presence of IEL rupture. Am J Physiol Heart Circ Physiol. 2002;283:H760-767.
    • (2002) Am J Physiol Heart Circ Physiol , vol.283
    • Indolfi, C.1    Torella, D.2    Coppola, C.3
  • 22
    • 0028912131 scopus 로고
    • Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance
    • Colombo A, Hall P, Nakamura S, et al. Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation. 1995;91:1676-1688.
    • (1995) Circulation , vol.91 , pp. 1676-1688
    • Colombo, A.1    Hall, P.2    Nakamura, S.3
  • 23
    • 0036146104 scopus 로고    scopus 로고
    • Hemodynamics and wall mechanics of a compliance matching stent: In vitro and in vivo analysis
    • Berry JL, Manoach E, Mekkaoui C, et al. Hemodynamics and wall mechanics of a compliance matching stent: in vitro and in vivo analysis. J Vasc Interv Radiol. 2002;13: 97-105.
    • (2002) J Vasc Interv Radiol , vol.13 , pp. 97-105
    • Berry, J.L.1    Manoach, E.2    Mekkaoui, C.3
  • 24
    • 0031838627 scopus 로고    scopus 로고
    • Validation of an automated technique for determining the mechanical characteristics of coronary arteries during balloon angioplasty: Laboratory assessment with necropsy segments
    • Murray A, Allen V, Bennett MK. Validation of an automated technique for determining the mechanical characteristics of coronary arteries during balloon angioplasty: laboratory assessment with necropsy segments. Heart. 1998;79: 608-612.
    • (1998) Heart , vol.79 , pp. 608-612
    • Murray, A.1    Allen, V.2    Bennett, M.K.3
  • 25
    • 34247268669 scopus 로고    scopus 로고
    • Modeling plaque fissuring and dissection during balloon angioplasty intervention
    • Gasser TC, Holzapfel GA. Modeling plaque fissuring and dissection during balloon angioplasty intervention. Ann Biomed Eng. 2007;35: 711-723.
    • (2007) Ann Biomed Eng , vol.35 , pp. 711-723
    • Gasser, T.C.1    Holzapfel, G.A.2
  • 26
    • 18044371469 scopus 로고    scopus 로고
    • Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries
    • LaDisa JF, Olson LE, Molthen RC, et al. Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries. Am J Physiol Heart Circ Physiol. 2005;288:H2465-2475.
    • (2005) Am J Physiol Heart Circ Physiol , vol.288
    • LaDisa, J.F.1    Olson, L.E.2    Molthen, R.C.3
  • 27
    • 23644444112 scopus 로고    scopus 로고
    • Blood flow in stented arteries: A parametric comparison of strut design patterns in three dimensions
    • He Y, Duraiswamy N, Frank AO, et al. Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions. J Biomech Eng. 2005;127:637-647.
    • (2005) J Biomech Eng , vol.127 , pp. 637-647
    • He, Y.1    Duraiswamy, N.2    Frank, A.O.3
  • 28
    • 0033623702 scopus 로고    scopus 로고
    • Experimental and computational flow evaluation of coronary stents
    • Berry JL, Santamarina A, Moore JE, et al. Experimental and computational flow evaluation of coronary stents. Ann Biomed Eng. 2000;28:386-398.
    • (2000) Ann Biomed Eng , vol.28 , pp. 386-398
    • Berry, J.L.1    Santamarina, A.2    Moore, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.