메뉴 건너뛰기




Volumn 26, Issue 1, 2009, Pages 93-95

Death caused by splenic artery aneurysm rupture during dobutamine-atropine stress echocardiography: Case report and literature review

Author keywords

DASE; Death; Dobutamine atropine stress echocardiography; Splenic artery aneurysm

Indexed keywords

ATROPINE; BLOOD CLOTTING FACTOR 7; DOBUTAMINE; RECOMBINANT PROTEIN;

EID: 58149184060     PISSN: 07422822     EISSN: 15408175     Source Type: Journal    
DOI: 10.1111/j.1540-8175.2008.00755.x     Document Type: Article
Times cited : (7)

References (9)
  • 1
    • 0025804432 scopus 로고
    • Echocardiographic detection of coronary artery disease during dobutamine infusion
    • Sawada SG, Segar DS, Ryan T, et al : Echocardiographic detection of coronary artery disease during dobutamine infusion. Circulation 1991 83 : 1605 1614.
    • (1991) Circulation , vol.83 , pp. 1605-1614
    • Sawada, S.G.1    Segar, D.S.2    Ryan, T.3
  • 2
    • 0027190017 scopus 로고
    • Symptoms, adverse effects, and complications associated with dobutamine stress echocardiography. Experience in 1118 patients
    • Mertes H, Sawada SG, Ryan T, et al : Symptoms, adverse effects, and complications associated with dobutamine stress echocardiography. Experience in 1118 patients. Circulation 1993 88 : 15 19.
    • (1993) Circulation , vol.88 , pp. 15-19
    • Mertes, H.1    Sawada, S.G.2    Ryan, T.3
  • 3
    • 0030958384 scopus 로고    scopus 로고
    • Evolution of dobutamine echocardiography protocols and indications: Safety and side effects in 3,011 studies over 5 years
    • Secknus MA, Marwick T : Evolution of dobutamine echocardiography protocols and indications: Safety and side effects in 3,011 studies over 5 years. J Am Coll Cardiol 1997 29 : 1234 1240.
    • (1997) J Am Coll Cardiol , vol.29 , pp. 1234-1240
    • Secknus, M.A.1    Marwick, T.2
  • 4
    • 0032834445 scopus 로고    scopus 로고
    • Safety of dobutamine-atropine stress echocardiography. A prospective experience of 4033 consecutive studies
    • Mathias W Jr., Arruda A, Santos F, et al : Safety of dobutamine-atropine stress echocardiography : A prospective experience of 4033 consecutive studies. J Am Soc Echocardiogr 1999 12 : 785 791.
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 785-791
    • Mathias Jr., W.1    Arruda, A.2    Santos, F.3
  • 5
    • 0034662793 scopus 로고    scopus 로고
    • Safety and efficacy of an accelerated dobutamine stress echocardiography protocol in the evaluation of coronary artery disease
    • Burger A, Notarianni M, Aronson D : Safety and efficacy of an accelerated dobutamine stress echocardiography protocol in the evaluation of coronary artery disease. Am J Cardiol 2000 86 : 825 829.
    • (2000) Am J Cardiol , vol.86 , pp. 825-829
    • Burger, A.1    Notarianni, M.2    Aronson, D.3
  • 6
    • 9344262899 scopus 로고    scopus 로고
    • Comparison of safety and efficacy of the early injection of atropine during dobutamine stress echocardiography with the conventional protocol
    • Tsutsui J, Osorio A, Lario F, et al : Comparison of safety and efficacy of the early injection of atropine during dobutamine stress echocardiography with the conventional protocol. Am J Cardiol 2004 94 : 1367 1372.
    • (2004) Am J Cardiol , vol.94 , pp. 1367-1372
    • Tsutsui, J.1    Osorio, A.2    Lario, F.3
  • 7
    • 0030041682 scopus 로고    scopus 로고
    • Safety of performing dobutamine stress echocardiography in patients with abdominal aortic aneurysm ≥4 cm in diameter
    • Pellikka P, Roger V, Oh J, et al : Safety of performing dobutamine stress echocardiography in patients with abdominal aortic aneurysm ≥4 cm in diameter. Am J Cardiol 1996 77 : 413 416.
    • (1996) Am J Cardiol , vol.77 , pp. 413-416
    • Pellikka, P.1    Roger, V.2    Oh, J.3
  • 8
    • 0036833828 scopus 로고    scopus 로고
    • Safety of dobutamine stress echocardiography in patients with unruptured intracranial aneurysms
    • Takhtehchian D, Novaro G, Barnett G, et al : Safety of dobutamine stress echocardiography in patients with unruptured intracranial aneurysms. J Am Soc Echocardiogr 2002 15 : 1401 1404.
    • (2002) J Am Soc Echocardiogr , vol.15 , pp. 1401-1404
    • Takhtehchian, D.1    Novaro, G.2    Barnett, G.3
  • 9
    • 0034931969 scopus 로고    scopus 로고
    • Hypotension and functional left ventricular obstruction during dobutamine stress echocardiography - Two case reports
    • Ueda T, Mizushige K, Yukiiri K, et al : Hypotension and functional left ventricular obstruction during dobutamine stress echocardiography - Two case reports. Angiology 2001 52 : 489 492.
    • (2001) Angiology , vol.52 , pp. 489-492
    • Ueda, T.1    Mizushige, K.2    Yukiiri, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.