메뉴 건너뛰기




Volumn 222, Issue 6, 2008, Pages 959-966

Biomechanical comparison of three second-generation reconstruction nails in an unstable subtrochanteric femur fracture model

Author keywords

Reconstruction nail; Subtrochanteric fracture

Indexed keywords

AXIAL DISPLACEMENTS; DYNAMIC STIFFNESS; FATIGUE LIVES; FRACTURE MODELS; IN CONTROLS; P VALUES; RECONSTRUCTION NAIL; SCREW HOLES; STIFFNESS VALUES; STRYKER; SUBTROCHANTERIC FRACTURE; TRANSVERSE DISPLACEMENTS; FRACTURE MODEL; SECOND GENERATION; SUBTROCHANTERIC FRACTURES; SYNTHETIC BONE;

EID: 58149161233     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM369     Document Type: Article
Times cited : (20)

References (38)
  • 1
    • 0005292483 scopus 로고    scopus 로고
    • Subtrochanteric fractures of the femur
    • Russell, T. A. and Taylor, J. C. Subtrochanteric fractures of the femur. Skeletal Trauma, 1998, 2, 1883-1925.
    • (1998) Skeletal Trauma , vol.2 , pp. 1883-1925
    • Russell, T.A.1    Taylor, J.C.2
  • 2
    • 0036194963 scopus 로고    scopus 로고
    • Subtrochanteric femur fractures
    • Sims, S. H. Subtrochanteric femur fractures. Orthop. Clin. North Am., 2002, 33(1), 113-126.
    • (2002) Orthop. Clin. North Am , vol.33 , Issue.1 , pp. 113-126
    • Sims, S.H.1
  • 3
    • 0017857584 scopus 로고
    • Subtrochanteric fractures of the femur
    • Seinsheimer, F. Subtrochanteric fractures of the femur. J. Bone Jt Surg. Am., 1978, 60A, 300-306.
    • (1978) J. Bone Jt Surg. Am , vol.60 A , pp. 300-306
    • Seinsheimer, F.1
  • 4
    • 0032088097 scopus 로고    scopus 로고
    • A mechanical comparison of subtrochanteric femur fracture fixation
    • Pugh, K. J., Morgan, R. A., Gorczyca, J. T., and Pienkowski, D. A mechanical comparison of subtrochanteric femur fracture fixation. J. Orthop. Trauma, 1998, 12, 324-329.
    • (1998) J. Orthop. Trauma , vol.12 , pp. 324-329
    • Pugh, K.J.1    Morgan, R.A.2    Gorczyca, J.T.3    Pienkowski, D.4
  • 5
    • 0021678609 scopus 로고
    • A biomechanical comparison of various methods of stabilization of subtrochanteric fractures of the femur
    • Tencer, A. F., Johnson, K. D., Johnston, D. W. C., and Gill, K. A biomechanical comparison of various methods of stabilization of subtrochanteric fractures of the femur. J. Orthop. Res., 1984, 2, 297-305.
    • (1984) J. Orthop. Res , vol.2 , pp. 297-305
    • Tencer, A.F.1    Johnson, K.D.2    Johnston, D.W.C.3    Gill, K.4
  • 6
    • 84920207932 scopus 로고
    • The laws of bone architecture
    • Koch, C. The laws of bone architecture. Am. J. Anatomy, 1907, 21, 177-298.
    • (1907) Am. J. Anatomy , vol.21 , pp. 177-298
    • Koch, C.1
  • 7
    • 4444232502 scopus 로고    scopus 로고
    • Subtrochanteric femur fractures
    • Bedi, A. and Toan Le, T. Subtrochanteric femur fractures. Orthop. Clin. North Am., 2004, 35(4), 437-483.
    • (2004) Orthop. Clin. North Am , vol.35 , Issue.4 , pp. 437-483
    • Bedi, A.1    Toan Le, T.2
  • 8
    • 0029851085 scopus 로고    scopus 로고
    • Fixation of segmental subtrochanteric fractures: A biomechanical study
    • Kraemer, W. J., Hearn, T. C., Powell, J. N., and Mahomed, N. Fixation of segmental subtrochanteric fractures: a biomechanical study. Clin. Orthop., 1996, 332, 71-79.
    • (1996) Clin. Orthop , vol.332 , pp. 71-79
    • Kraemer, W.J.1    Hearn, T.C.2    Powell, J.N.3    Mahomed, N.4
  • 9
    • 0031000260 scopus 로고    scopus 로고
    • Parker, M. J., Dutta, B. K., Sivaji, C., and Pryor, G. A. Subtrochanteric fractures of the femur. Injury, 1997, 28(2), 91-95.
    • Parker, M. J., Dutta, B. K., Sivaji, C., and Pryor, G. A. Subtrochanteric fractures of the femur. Injury, 1997, 28(2), 91-95.
  • 10
    • 0018650277 scopus 로고
    • Subtrochanteric fractures of the femur: A review of 130 patients
    • Waddell, J. P. Subtrochanteric fractures of the femur: a review of 130 patients. J. Trauma, 1979, 19, 582-592.
    • (1979) J. Trauma , vol.19 , pp. 582-592
    • Waddell, J.P.1
  • 12
    • 0028965099 scopus 로고
    • The DCS in the management of subtrochanteric fractures of the femur
    • Warwick, D. J., Crichlow, T. P. K. R., Langkamer, V. G., and Jackson, M. The DCS in the management of subtrochanteric fractures of the femur. Injury, 1995, 26(4), 241-244.
    • (1995) Injury , vol.26 , Issue.4 , pp. 241-244
    • Warwick, D.J.1    Crichlow, T.P.K.R.2    Langkamer, V.G.3    Jackson, M.4
  • 13
    • 0027170493 scopus 로고
    • A prospective randomized comparison of the DHS and the Gamma locking nail
    • Radford, P. J., Needoff, M., and Webb, J. K. A prospective randomized comparison of the DHS and the Gamma locking nail. J. Bone Jt Surg. Br., 1993, 75, 789-793.
    • (1993) J. Bone Jt Surg. Br , vol.75 , pp. 789-793
    • Radford, P.J.1    Needoff, M.2    Webb, J.K.3
  • 14
    • 0034276762 scopus 로고    scopus 로고
    • Evaluation and treatment of high subtrochanteric femur fractures
    • Herscovici, D., Pistel, W. L., and Sanders, R. W. Evaluation and treatment of high subtrochanteric femur fractures. Am. J. Orthop., 2000, 29(9 Suppl), 27-33.
    • (2000) Am. J. Orthop , vol.29 , Issue.9 SUPPL. , pp. 27-33
    • Herscovici, D.1    Pistel, W.L.2    Sanders, R.W.3
  • 15
    • 0036226889 scopus 로고    scopus 로고
    • Second generation intramedullary nailing of subtrochanteric femur fractures: A biomechanical study of fracture site motion
    • Roberts, C. S., Nawab, A., Wang, M., Voor, M. J., and Seligson, D. Second generation intramedullary nailing of subtrochanteric femur fractures: a biomechanical study of fracture site motion. J. Orthop. Trauma, 2002, 16(4), 231-238.
    • (2002) J. Orthop. Trauma , vol.16 , Issue.4 , pp. 231-238
    • Roberts, C.S.1    Nawab, A.2    Wang, M.3    Voor, M.J.4    Seligson, D.5
  • 18
    • 0042796183 scopus 로고    scopus 로고
    • American Society for Testing and Materials ASTM, section 13, Medical Devices and Services 13.01, ASTM, West Conshohocken, PA
    • American Society for Testing and Materials (ASTM). Annual book of ASTM standards, section 13, Medical Devices and Services 13.01, 2003 (ASTM, West Conshohocken, PA).
    • (2003) Annual book of ASTM standards
  • 19
    • 7044285751 scopus 로고    scopus 로고
    • The fixion proximal femur nailing system: Biomechanical properties of the nail and a cadaveric study
    • Steinberg, E., Blumberg, N., and Dekel, S. The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study. J. Biomechanics, 2005, 38, 63-68.
    • (2005) J. Biomechanics , vol.38 , pp. 63-68
    • Steinberg, E.1    Blumberg, N.2    Dekel, S.3
  • 21
    • 0008858152 scopus 로고    scopus 로고
    • Photoelastic investigations of various implants (DHS and Gamma Nail) used to stabilize peritrochanteric femoral fractures
    • Eds R. H. Gahr, K.-S. Leung, and M. P. Rossenwasser, Einhorn-Presse Verlag, Reinbeck, Germany
    • Euler, E., Huber, S., and Heining, S. Photoelastic investigations of various implants (DHS and Gamma Nail) used to stabilize peritrochanteric femoral fractures. In The Gamma locking nail (Eds R. H. Gahr, K.-S. Leung, and M. P. Rossenwasser), 1999, pp. 272-277 (Einhorn-Presse Verlag, Reinbeck, Germany).
    • (1999) The Gamma locking nail , pp. 272-277
    • Euler, E.1    Huber, S.2    Heining, S.3
  • 22
    • 0008838114 scopus 로고    scopus 로고
    • Biomechanical investigations of the fatigue loading of internal fixation of the trochanter region of the femur
    • Eds R. H. Gahr, K.-S. Leung, and M. P. Rossenwasser, Einhorn-Presse Verlag, Reinbeck, Germany
    • Kreusch-Brinker, R., Rohlmann, A., and Jensen, H. I. Biomechanical investigations of the fatigue loading of internal fixation of the trochanter region of the femur. In The Gamma locking nail (Eds R. H. Gahr, K.-S. Leung, and M. P. Rossenwasser), 1999, pp. 67-79 (Einhorn-Presse Verlag, Reinbeck, Germany).
    • (1999) The Gamma locking nail , pp. 67-79
    • Kreusch-Brinker, R.1    Rohlmann, A.2    Jensen, H.I.3
  • 23
    • 0026604141 scopus 로고
    • The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
    • Huiskes, R., Weinans, H., and Van Rietbergen, B. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin. Orthop., 1992, 274, 124-134.
    • (1992) Clin. Orthop , vol.274 , pp. 124-134
    • Huiskes, R.1    Weinans, H.2    Van Rietbergen, B.3
  • 24
    • 0026560894 scopus 로고
    • Determinants of stress shielding: Design versus materials versus interface
    • Sumner, D. R. and Galante, J. O. Determinants of stress shielding: design versus materials versus interface. Clin. Orthop., 1992, 274, 202-212.
    • (1992) Clin. Orthop , vol.274 , pp. 202-212
    • Sumner, D.R.1    Galante, J.O.2
  • 25
    • 0028528650 scopus 로고
    • A prospective comparative study of the compression hip screw and gamma nail
    • Goldhagen, P. R., O'Connor, D. R., Schwarze, D., and Schwartz, E. A prospective comparative study of the compression hip screw and gamma nail. J. Orthop. Trauma, 1994, 8(5), 367-672.
    • (1994) J. Orthop. Trauma , vol.8 , Issue.5 , pp. 367-672
    • Goldhagen, P.R.1    O'Connor, D.R.2    Schwarze, D.3    Schwartz, E.4
  • 26
    • 0026288485 scopus 로고
    • Subtrochanteric femur fractures: A comparison of the Zickel nail, 95° blade plate, and interlocking nail
    • Brien, W. W., Wiss, D. A., Becker, V., and Lehman, T. Subtrochanteric femur fractures: a comparison of the Zickel nail, 95° blade plate, and interlocking nail. J. Orthop. Trauma, 1991, 5(4), 458-464.
    • (1991) J. Orthop. Trauma , vol.5 , Issue.4 , pp. 458-464
    • Brien, W.W.1    Wiss, D.A.2    Becker, V.3    Lehman, T.4
  • 27
    • 0024367732 scopus 로고
    • Treatment of subtrochanteric femur fractures using the dynamic condylar screw
    • Sanders, R. and Regazzoni, P. Treatment of subtrochanteric femur fractures using the dynamic condylar screw. J. Orthop. Trauma, 1989, 3(3), 206- 213.
    • (1989) J. Orthop. Trauma , vol.3 , Issue.3 , pp. 206-213
    • Sanders, R.1    Regazzoni, P.2
  • 28
    • 0026699263 scopus 로고
    • Subtrochanteric fractures of the femur. Results of treatment by interlocking nailing
    • Wiss, D. A. and Brien, W. W. Subtrochanteric fractures of the femur. Results of treatment by interlocking nailing. Clin. Orthop. Related Res., 1992, 283, 231-236.
    • (1992) Clin. Orthop. Related Res , vol.283 , pp. 231-236
    • Wiss, D.A.1    Brien, W.W.2
  • 29
    • 0031921335 scopus 로고    scopus 로고
    • Use of an interlocked cephalomedullary nail for subtrochanteric fracture stabilization
    • French, B. G. and Tornetta, P. Use of an interlocked cephalomedullary nail for subtrochanteric fracture stabilization. Clin. Orthop., 1998, 348, 95-100.
    • (1998) Clin. Orthop , vol.348 , pp. 95-100
    • French, B.G.1    Tornetta, P.2
  • 31
    • 33947267578 scopus 로고    scopus 로고
    • Fatigue characteristics of metallic biomaterials
    • Niinomi, N. Fatigue characteristics of metallic biomaterials. Int. J. Fatigue, 2007, 29, 992-1000.
    • (2007) Int. J. Fatigue , vol.29 , pp. 992-1000
    • Niinomi, N.1
  • 32
    • 0036899174 scopus 로고    scopus 로고
    • Evaluation techniques of metallic biomaterials in vitro
    • Hanawa, T. Evaluation techniques of metallic biomaterials in vitro. Sci. Technol. Adv Mater., 2002, 3, 289-295.
    • (2002) Sci. Technol. Adv Mater , vol.3 , pp. 289-295
    • Hanawa, T.1
  • 33
    • 0034317060 scopus 로고    scopus 로고
    • Fatigue of biomaterials: A review
    • Teoh, S. H. Fatigue of biomaterials: a review. Int. J. Fatigue, 2000, 22, 825-837.
    • (2000) Int. J. Fatigue , vol.22 , pp. 825-837
    • Teoh, S.H.1
  • 34
    • 2942534210 scopus 로고    scopus 로고
    • Mechanics considerations for microporous titanium as an orthopedic implant material
    • Thelen, S., Barthelat, F., and Brinson, L. C. Mechanics considerations for microporous titanium as an orthopedic implant material. J. Biomed. Mater. Res. A, 2004, 69, 601-610.
    • (2004) J. Biomed. Mater. Res. A , vol.69 , pp. 601-610
    • Thelen, S.1    Barthelat, F.2    Brinson, L.C.3
  • 35
    • 4043146455 scopus 로고    scopus 로고
    • Development of a beta-type Ti-12Mo-5Ta alloy for biomedical applications: Cyctocompatibility and metallurgical aspects
    • Gordin, D. M., Gloriant, T., Texier, G., Thibon, I., Ansel, D., Duval, J. L., and Nagel, M. D. Development of a beta-type Ti-12Mo-5Ta alloy for biomedical applications: cyctocompatibility and metallurgical aspects. J. Mater. Sci. Mater. Med., 2004, 15, 885-891.
    • (2004) J. Mater. Sci. Mater. Med , vol.15 , pp. 885-891
    • Gordin, D.M.1    Gloriant, T.2    Texier, G.3    Thibon, I.4    Ansel, D.5    Duval, J.L.6    Nagel, M.D.7
  • 36
    • 31044438487 scopus 로고    scopus 로고
    • Fabrication methods of porous metals for use in orthopaedic applications
    • Ryan, G., Pandit, A., and Apatsidis, D. P. Fabrication methods of porous metals for use in orthopaedic applications. Biomaterials, 2006, 27, 2651- 2670.
    • (2006) Biomaterials , vol.27 , pp. 2651-2670
    • Ryan, G.1    Pandit, A.2    Apatsidis, D.P.3
  • 37
    • 16544375763 scopus 로고    scopus 로고
    • Predicting graded Young modulus values of Ti alloys modified by ion implantation
    • Hassan, M. H. Predicting graded Young modulus values of Ti alloys modified by ion implantation. Med. J. Malaysia, 2004, 59(Suppl B), 164-165.
    • (2004) Med. J. Malaysia , vol.59 , Issue.SUPPL. B , pp. 164-165
    • Hassan, M.H.1
  • 38
    • 65249165757 scopus 로고    scopus 로고
    • Mow, V. C, and Hayes, W. C, Eds, 2nd edition, Raven Press, New York
    • Mow, V. C., and Hayes, W. C. (Eds) Basic orthopaedic biomechanics, 2nd edition, 1997, p. 85 (Raven Press, New York).
    • (1997) Basic orthopaedic biomechanics , pp. 85


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.