메뉴 건너뛰기




Volumn 33, Issue 2, 2009, Pages 122-130

Improvement of cardiac CT reconstruction using local motion vector fields

Author keywords

Calcium scoring; Cardiac CT; Motion compensated reconstruction; Motion model

Indexed keywords

CARDIAC CT; CARDIAC IMAGING; CARDIAC PHASIS; CARDIAC RECONSTRUCTIONS; CT RECONSTRUCTIONS; FILTERED BACK PROJECTIONS; GATING WINDOWS; HELICAL CONE BEAMS; HIGH CONTRASTS; HOUNSFIELD UNITS; LOCAL MOTION VECTORS; MOTION ARTEFACTS; MOTION BLURS; MOTION COMPENSATED RECONSTRUCTION; MOTION MODEL; MOTION VECTOR FIELDS; PARAMETER SPACES; RECONSTRUCTION QUALITIES; ROBUST METHODS; SIGNAL TO NOISES; SOFTWARE PHANTOMS; STRONG MOTIONS; TEMPORAL INTERPOLATIONS;

EID: 58149142813     PISSN: 08956111     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compmedimag.2008.10.012     Document Type: Article
Times cited : (15)

References (26)
  • 2
    • 33746408724 scopus 로고    scopus 로고
    • Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis
    • Garcia M., Lessick J., and Hoffmann M. Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA 296 4 (2006) 403-411
    • (2006) JAMA , vol.296 , Issue.4 , pp. 403-411
    • Garcia, M.1    Lessick, J.2    Hoffmann, M.3
  • 3
    • 4444324085 scopus 로고    scopus 로고
    • Automatic phase determination for retrospectively gated cardiac ct
    • Manzke R., Köhler T., Nielsen T., Hawkes D., and Grass M. Automatic phase determination for retrospectively gated cardiac ct. Med Phys 31 12 (2004) 3345-3362
    • (2004) Med Phys , vol.31 , Issue.12 , pp. 3345-3362
    • Manzke, R.1    Köhler, T.2    Nielsen, T.3    Hawkes, D.4    Grass, M.5
  • 4
    • 31444448156 scopus 로고    scopus 로고
    • Automatic determination of minimal cardiac motion phases for computed tomography imaging: initial experience
    • Hoffmann M., Lessick J., Manzke R., Schmid F., Gershin E., Boll D.,., et al. Automatic determination of minimal cardiac motion phases for computed tomography imaging: initial experience. Eur Radiol 16 (2006) 365-373
    • (2006) Eur Radiol , vol.16 , pp. 365-373
    • Hoffmann, M.1    Lessick, J.2    Manzke, R.3    Schmid, F.4    Gershin, E.5    Boll, D.,.6
  • 5
    • 33745868752 scopus 로고    scopus 로고
    • Aperture weighted cardiac reconstruction for cone-beam CT
    • Koken P., and Grass M. Aperture weighted cardiac reconstruction for cone-beam CT. Phys Med Biol 51 14 (2006) 3433-3448
    • (2006) Phys Med Biol , vol.51 , Issue.14 , pp. 3433-3448
    • Koken, P.1    Grass, M.2
  • 6
    • 33746896543 scopus 로고    scopus 로고
    • Properties of the prototype 256-row (cone beam) ct scanner
    • Mori S., Endo M., Obata T., Tsunoo T., Susumu K., and Tanada S. Properties of the prototype 256-row (cone beam) ct scanner. Eur Radiol 16 (2006) 2100-2108
    • (2006) Eur Radiol , vol.16 , pp. 2100-2108
    • Mori, S.1    Endo, M.2    Obata, T.3    Tsunoo, T.4    Susumu, K.5    Tanada, S.6
  • 8
    • 58149176306 scopus 로고    scopus 로고
    • Glasberg S, Farjon D, Ankry M, Eisenbach S, Shnapp M, Altman A. Robust temporal resolution of msct cardiac scan by rotation-time update scheme based on analysis of patient ecg database, vol. 6510. SPIE; 2007: 65102Q.
    • Glasberg S, Farjon D, Ankry M, Eisenbach S, Shnapp M, Altman A. Robust temporal resolution of msct cardiac scan by rotation-time update scheme based on analysis of patient ecg database, vol. 6510. SPIE; 2007: 65102Q.
  • 9
    • 0030169071 scopus 로고    scopus 로고
    • Correction of computed tomography motion artifacts using pixel-specific back-projection, Medical Imaging
    • Ritchie C., Crawford C., Godwin J., King K., and Kim Y. Correction of computed tomography motion artifacts using pixel-specific back-projection, Medical Imaging. IEEE Transactions on 15 (3) (Jun 1996) 333-342
    • (1996) IEEE Transactions on 15 (3) , pp. 333-342
    • Ritchie, C.1    Crawford, C.2    Godwin, J.3    King, K.4    Kim, Y.5
  • 10
    • 0037036597 scopus 로고    scopus 로고
    • Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model
    • Grangeat P., Koenig A., Rodet T., and Bonnet S. Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model. Phys Med Biol 47 15 (2002) 2611-2625
    • (2002) Phys Med Biol , vol.47 , Issue.15 , pp. 2611-2625
    • Grangeat, P.1    Koenig, A.2    Rodet, T.3    Bonnet, S.4
  • 11
    • 3042819710 scopus 로고    scopus 로고
    • 3d tomographic reconstruction of coronary arteries using a precomputed 4d motion field
    • Blondel C., Vaillant R., Malandain G., and Ayache N. 3d tomographic reconstruction of coronary arteries using a precomputed 4d motion field. Phys Med Biol 49 11 (2004) 2197-2208
    • (2004) Phys Med Biol , vol.49 , Issue.11 , pp. 2197-2208
    • Blondel, C.1    Vaillant, R.2    Malandain, G.3    Ayache, N.4
  • 12
    • 3042739838 scopus 로고    scopus 로고
    • Exact reconstruction in 2d dynamic CT: compensation of time-dependent affine deformations
    • Sebastien Roux A.K., Laurent Desbat, and Grangeat P. Exact reconstruction in 2d dynamic CT: compensation of time-dependent affine deformations. Phys Med Biol 49 11 (2004) 2169-2182
    • (2004) Phys Med Biol , vol.49 , Issue.11 , pp. 2169-2182
    • Sebastien Roux, A.K.1    Laurent Desbat2    Grangeat, P.3
  • 14
    • 33745161519 scopus 로고    scopus 로고
    • von Berg J, Begemann P, Stahmer F, Adam G, Lorenz C. Automatic LV volume measurement in low dose multi-phase CT by shape tracking. In: Medical Imaging 2006: Image Processing, vol. 6144. SPIE; 2006.
    • von Berg J, Begemann P, Stahmer F, Adam G, Lorenz C. Automatic LV volume measurement in low dose multi-phase CT by shape tracking. In: Medical Imaging 2006: Image Processing, vol. 6144. SPIE; 2006.
  • 15
    • 58149167253 scopus 로고    scopus 로고
    • Taguchi C, Sun Z, Segars WP, Fishman EK, Tsui BMW. Image-domain motion compensated time-resolved 4d cardiac CT. In: Medical Imaging 2007. Physics of Medical Imaging, vol. 6510. SPIE; 2007.
    • Taguchi C, Sun Z, Segars WP, Fishman EK, Tsui BMW. Image-domain motion compensated time-resolved 4d cardiac CT. In: Medical Imaging 2007. Physics of Medical Imaging, vol. 6510. SPIE; 2007.
  • 16
    • 0037903112 scopus 로고    scopus 로고
    • Assessment of calcium scoring performance in cardiac computed tomography
    • Ulzheimer S., and Kalender W. Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13 3 (2003) 484-497
    • (2003) Eur Radiol , vol.13 , Issue.3 , pp. 484-497
    • Ulzheimer, S.1    Kalender, W.2
  • 17
    • 0031720879 scopus 로고    scopus 로고
    • Coronary artery disease: improved reproducibility of calcium scoring with an electron-beam CT volumetric method
    • Callister T., Cooil B., Raya S., Lippolis N., Russo D., and Raggi P. Coronary artery disease: improved reproducibility of calcium scoring with an electron-beam CT volumetric method. Radiology 208 3 (1998) 807-814
    • (1998) Radiology , vol.208 , Issue.3 , pp. 807-814
    • Callister, T.1    Cooil, B.2    Raya, S.3    Lippolis, N.4    Russo, D.5    Raggi, P.6
  • 18
    • 33746191817 scopus 로고    scopus 로고
    • Motion-compensated and gated cone beam filtered back-projection for 3-D rotational X-ray angiography
    • Schaefer D., Borgert J., Rasche V., and Grass M. Motion-compensated and gated cone beam filtered back-projection for 3-D rotational X-ray angiography. IEEE Trans Med Imag 25 (2006) 898-906
    • (2006) IEEE Trans Med Imag , vol.25 , pp. 898-906
    • Schaefer, D.1    Borgert, J.2    Rasche, V.3    Grass, M.4
  • 19
    • 34547095487 scopus 로고    scopus 로고
    • Begemann PG, van Stevendaal U, Koester R, Mahnken AH, Koops A, Adam G, Grass M, Nolte-Ernsting C. Evaluation of the influence of acquisition and reconstruction parameters for 16-row multidetector CT on coronary calcium scoring using a stationary and dynamic cardiac phantom. Eur Radiol 2007;17(8):1985-1994.
    • Begemann PG, van Stevendaal U, Koester R, Mahnken AH, Koops A, Adam G, Grass M, Nolte-Ernsting C. Evaluation of the influence of acquisition and reconstruction parameters for 16-row multidetector CT on coronary calcium scoring using a stationary and dynamic cardiac phantom. Eur Radiol 2007;17(8):1985-1994.
  • 20
    • 46149106379 scopus 로고    scopus 로고
    • van Stevendaal U, von Berg J, Lorenz C, Grass M. A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography. Med Phys 2008;35(7):3239-3251.
    • van Stevendaal U, von Berg J, Lorenz C, Grass M. A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography. Med Phys 2008;35(7):3239-3251.
  • 22
    • 3042640696 scopus 로고    scopus 로고
    • Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam ct with arbitrary pitch, arbitrary cone-angle, and 100 dose usage
    • Kachelriess M., Knaup M., and Kalender W. Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam ct with arbitrary pitch, arbitrary cone-angle, and 100 dose usage. Med Phys 31 (2004) 1623-1641
    • (2004) Med Phys , vol.31 , pp. 1623-1641
    • Kachelriess, M.1    Knaup, M.2    Kalender, W.3
  • 23
    • 33746644138 scopus 로고    scopus 로고
    • Bontus C, KP, Köhler T, Grass M. CE nPiT: helical cardiac CT reconstruction. Med Phys 2006;33(8):2792-99.
    • Bontus C, KP, Köhler T, Grass M. CE nPiT: helical cardiac CT reconstruction. Med Phys 2006;33(8):2792-99.
  • 24
    • 0347625749 scopus 로고    scopus 로고
    • Adaptive temporal resolution optimization in helical cardiac cone beam ct reconstruction
    • Manzke R., Grass M., Nielsen T., Shechter G., and Hawkes D. Adaptive temporal resolution optimization in helical cardiac cone beam ct reconstruction. Med Phys 30 12 (2003) 3072-3080
    • (2003) Med Phys , vol.30 , Issue.12 , pp. 3072-3080
    • Manzke, R.1    Grass, M.2    Nielsen, T.3    Shechter, G.4    Hawkes, D.5
  • 26
    • 17144395992 scopus 로고    scopus 로고
    • Helical cardiac cone beam ct reconstruction with large area detectors: a simulation study
    • Manzke R., Koken P., Hawkes D., and Grass M. Helical cardiac cone beam ct reconstruction with large area detectors: a simulation study. Phys Med Biol 50 7 (2005) 1547-1568
    • (2005) Phys Med Biol , vol.50 , Issue.7 , pp. 1547-1568
    • Manzke, R.1    Koken, P.2    Hawkes, D.3    Grass, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.