Volumn 591-593, Issue , 2008, Pages 36-41
|
Porosity characterization of sintered titanium scaffolds for surgical implants
|
Author keywords
Gamma ray transmission; Implant; Scaffold; Titanium; X ray microtomography
|
Indexed keywords
COMPUTERIZED TOMOGRAPHY;
GAMMA RAYS;
IMPLANTS (SURGICAL);
METALLOGRAPHY;
PORE SIZE;
POWDER METALLURGY;
POWDER TECHNOLOGY;
SCAFFOLDS;
SCAFFOLDS (BIOLOGY);
SCANNING ELECTRON MICROSCOPY;
TITANIUM;
TOPOGRAPHY;
TRANSMISSIONS;
X RAYS;
BIOMATERIAL SCAFFOLDS;
CRITICAL FEATURES;
MECHANICAL INTERLOCKING;
METALLOGRAPHIC ANALYSIS;
POROSITY AND PORE SIZE;
POROSITY ASSESSMENTS;
TITANIUM SCAFFOLDS;
X RAY MICROTOMOGRAPHY;
METAL IMPLANTS;
|
EID: 58149129041
PISSN: 02555476
EISSN: 16629752
Source Type: Book Series
DOI: 10.4028/www.scientific.net/msf.591-593.36 Document Type: Conference Paper |
Times cited : (8)
|
References (13)
|