메뉴 건너뛰기




Volumn 20, Issue 1, 2009, Pages 76-81

Subcutaneous bioimpedance recording: Assessment of a method for hemodynamic monitoring by implanted devices

Author keywords

Arrhythmias; Bioimpedance; Hypotension; Implantable monitor; Syncope

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTERIAL PRESSURE; ARTICLE; BLOOD FLOW; BLOOD VOLUME; CONTROLLED STUDY; DEVICE; ELECTRODE; FEMALE; HEMODYNAMIC MONITORING; HYPOTENSION; MEAN ARTERIAL PRESSURE; MEDICAL ASSESSMENT; NONHUMAN; PECTORAL MUSCLE; PRIORITY JOURNAL; PULSE PRESSURE; SWINE;

EID: 58149115051     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2008.01271.x     Document Type: Article
Times cited : (6)

References (27)
  • 2
    • 0032127762 scopus 로고    scopus 로고
    • Final results from a pilot study with an implantable loop recorder to determine the etiology of syncope in patients with negative noninvasive and invasive testing
    • Krahn A, Klein GJ, Yee R, Norris C : Final results from a pilot study with an implantable loop recorder to determine the etiology of syncope in patients with negative noninvasive and invasive testing. Am J Cardiol 1998 82 : 117 119.
    • (1998) Am J Cardiol , vol.82 , pp. 117-119
    • Krahn, A.1    Klein, G.J.2    Yee, R.3    Norris, C.4
  • 3
    • 0032943618 scopus 로고    scopus 로고
    • Use of an extended monitoring strategy in patients with problematic syncope. Reveal investigators
    • Krahn AD, Klein GJ, Yee R, Takle-Newhouse T, Norris C : Use of an extended monitoring strategy in patients with problematic syncope. Reveal investigators. Circulation 1999 26 : 406 410.
    • (1999) Circulation , vol.26 , pp. 406-410
    • Krahn, A.D.1    Klein, G.J.2    Yee, R.3    Takle-Newhouse, T.4    Norris, C.5
  • 7
    • 0030919651 scopus 로고    scopus 로고
    • Clinical guideline. Diagnosing syncope. Part 1: Value of history, clinical examination, and electrocardiography
    • Linzer M, Yang E, Estes M, Wang P, Vorperian VR, Kapoor WN : Clinical guideline. Diagnosing syncope. Part 1: Value of history, clinical examination, and electrocardiography. Ann Intern Med 1997 126 : 989 996.
    • (1997) Ann Intern Med , vol.126 , pp. 989-996
    • Linzer, M.1    Yang, E.2    Estes, M.3    Wang, P.4    Vorperian, V.R.5    Kapoor, W.N.6
  • 8
    • 14844295467 scopus 로고    scopus 로고
    • Clinical practice. Neurocardiogenic syncope
    • Grubb BP : Clinical practice. Neurocardiogenic syncope. N Engl J Med 2005 10 : 1004 1010.
    • (2005) N Engl J Med , vol.10 , pp. 1004-1010
    • Grubb, B.P.1
  • 10
    • 8644263005 scopus 로고    scopus 로고
    • Pathophysiology of syncope
    • Hainsworth R : Pathophysiology of syncope. Clin Auton Res 2004 14 (Suppl 1 18 24.
    • (2004) Clin Auton Res , vol.14 , Issue.1 , pp. 18-24
    • Hainsworth, R.1
  • 13
    • 4344683588 scopus 로고    scopus 로고
    • Holter-type impedance cardiography device. a system for continuous and non-invasive monitoring of cardiac haemodynamics
    • Cybulski G, Kozluk E, Michalak E, Niewlamdoski W, Platkowska A : Holter-type impedance cardiography device. A system for continuous and non-invasive monitoring of cardiac haemodynamics. Kardiol Pol 2004 61 : 138 146.
    • (2004) Kardiol Pol , vol.61 , pp. 138-146
    • Cybulski, G.1    Kozluk, E.2    Michalak, E.3    Niewlamdoski, W.4    Platkowska, A.5
  • 14
    • 0031793753 scopus 로고    scopus 로고
    • Ambulatory impedance cardiography: A feasibility study
    • Sherwood A, McFetridge J, Hutcheson JS : Ambulatory impedance cardiography: A feasibility study. J Appl Physiol 1998 85 : 2365 2369.
    • (1998) J Appl Physiol , vol.85 , pp. 2365-2369
    • Sherwood, A.1    McFetridge, J.2    Hutcheson, J.S.3
  • 15
    • 8344221038 scopus 로고    scopus 로고
    • Noninvasive hemodynamic monitoring in heart failure: Utilization of impedance cardiography
    • Yancy C, Abraham WT : Noninvasive hemodynamic monitoring in heart failure: Utilization of impedance cardiography. Congest Heart Fail 2003 9 : 241 250.
    • (2003) Congest Heart Fail , vol.9 , pp. 241-250
    • Yancy, C.1    Abraham, W.T.2
  • 18
    • 0036024423 scopus 로고    scopus 로고
    • Combination drug therapy with vasopressin, adrenaline (epinephrine) and nitroglycerin improves vital organ blood flow in a porcine model of ventricular fibrillation
    • Lurie KG, Voelckel WG, Iskos DN, McKnite SH, Zielinski TM, Sugiyama A, Wenzel V, Benditt D, Lindner KH : Combination drug therapy with vasopressin, adrenaline (epinephrine) and nitroglycerin improves vital organ blood flow in a porcine model of ventricular fibrillation. Resuscitation 2002 54 : 187 194.
    • (2002) Resuscitation , vol.54 , pp. 187-194
    • Lurie, K.G.1    Voelckel, W.G.2    Iskos, D.N.3    McKnite, S.H.4    Zielinski, T.M.5    Sugiyama, A.6    Wenzel, V.7    Benditt, D.8    Lindner, K.H.9
  • 21
    • 1842738291 scopus 로고    scopus 로고
    • Reducing ventilation frequency combined with an inspiratory impedance device improves CPR efficiency in swine model of cardiac arrest
    • Yannopoulos D, Sigurdsson G, McKnite S, Benditt D, Lurie KG : Reducing ventilation frequency combined with an inspiratory impedance device improves CPR efficiency in swine model of cardiac arrest. Resuscitation 2004 61 : 75 82.
    • (2004) Resuscitation , vol.61 , pp. 75-82
    • Yannopoulos, D.1    Sigurdsson, G.2    McKnite, S.3    Benditt, D.4    Lurie, K.G.5
  • 22
    • 14544292896 scopus 로고    scopus 로고
    • Effects of incomplete chest wall decompression during cardiopulmonary resuscitation on coronary and cerebral perfusion pressures in a porcine model of cardiac arrest
    • Yannopoulos D, McKnite S, Aufderheide TP, Sigurdsson G, Pirrallo RG, Benditt D, Lurie KG : Effects of incomplete chest wall decompression during cardiopulmonary resuscitation on coronary and cerebral perfusion pressures in a porcine model of cardiac arrest. Resuscitation 2005 64 : 363 372.
    • (2005) Resuscitation , vol.64 , pp. 363-372
    • Yannopoulos, D.1    McKnite, S.2    Aufderheide, T.P.3    Sigurdsson, G.4    Pirrallo, R.G.5    Benditt, D.6    Lurie, K.G.7
  • 23
    • 0025370374 scopus 로고
    • Normal physiological values for conscious pigs used in biomedical research
    • Hannon JP, Bossone CA, Wade CE : Normal physiological values for conscious pigs used in biomedical research. Lab Anim Sci 1990 40 : 293 298.
    • (1990) Lab Anim Sci , vol.40 , pp. 293-298
    • Hannon, J.P.1    Bossone, C.A.2    Wade, C.E.3
  • 24
    • 23844525145 scopus 로고    scopus 로고
    • Intrathoracic impedance monitoring in patients with heart failure: Correlation with fluid status and feasibility of early warning preceding hospitalization
    • Yu C-M, Wang L, Chau E, Chan RH, Kong SL, Tang MO, Christensen J, Stadler RW, Lau C-P : Intrathoracic impedance monitoring in patients with heart failure: Correlation with fluid status and feasibility of early warning preceding hospitalization. Circulation 2005 112 : 841 848.
    • (2005) Circulation , vol.112 , pp. 841-848
    • Yu, C.-M.1    Wang, L.2    Chau, E.3    Chan, R.H.4    Kong, S.L.5    Tang, M.O.6    Christensen, J.7    Stadler, R.W.8    Lau, C.-P.9
  • 25
    • 33749047463 scopus 로고    scopus 로고
    • New approaches to monitoring heart failure before symptoms appear
    • Abraham WT : New approaches to monitoring heart failure before symptoms appear. Rev Cardiovasc Med 2006 7 (Suppl 1 S33 S41.
    • (2006) Rev Cardiovasc Med , vol.7 , Issue.1
    • Abraham, W.T.1
  • 26
    • 37649009198 scopus 로고    scopus 로고
    • OptiVol fluid status monitoring with an implantable cardiac device: A heart failure management system
    • Yamokoski LM, Haas GJ, Gans B, Abraham WT : OptiVol fluid status monitoring with an implantable cardiac device: A heart failure management system. Expert Rev Med Devices 2007 4 : 775 780.
    • (2007) Expert Rev Med Devices , vol.4 , pp. 775-780
    • Yamokoski, L.M.1    Haas, G.J.2    Gans, B.3    Abraham, W.T.4
  • 27
    • 34248555446 scopus 로고    scopus 로고
    • Insights from a large heart failure clinic
    • Integrating device-based monitoring into clinical practice
    • Small RS : Integrating device-based monitoring into clinical practice : Insights from a large heart failure clinic. Am J Cardiol 2007 99 : 17G 22G.
    • (2007) Am J Cardiol , vol.99
    • Small, R.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.