메뉴 건너뛰기




Volumn , Issue , 2008, Pages

A new robust method to detect rotor faults in salient-pole synchronous machines using structural asymmetries

Author keywords

Broken damper bars; Inter turn faults; Modified winding function approach (MWFA); Synchronous machine (SM)

Indexed keywords

DAMPING; INDUCTION MOTORS; PAPER; POLES; ROTORS (WINDINGS); SYNCHRONOUS MOTORS; WINDING;

EID: 57949090131     PISSN: 01972618     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/08IAS.2008.22     Document Type: Conference Paper
Times cited : (34)

References (14)
  • 1
    • 29244467991 scopus 로고    scopus 로고
    • Condition Monitoring and Fault Diagnosis of Electrical Motors-A Review
    • Dec
    • S. Nandi, H. A. Toliyat and X. Li, "Condition Monitoring and Fault Diagnosis of Electrical Motors-A Review," IEEE Transactions on Energy Conversion, vol. 20, no. 4, pp. 719-729, Dec. 2005.
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , Issue.4 , pp. 719-729
    • Nandi, S.1    Toliyat, H.A.2    Li, X.3
  • 3
    • 0030173249 scopus 로고    scopus 로고
    • Detection of shorted-turns in the field winding of turbine-generator rotors using novelty detectors - development and field test
    • June
    • R. J. Streifel, R. J. Marks II, M.A. El-Sharkawi, and I. Kerszenbaum, "Detection of shorted-turns in the field winding of turbine-generator rotors using novelty detectors - development and field test," IEEE Transactions on Energy Conversion, vol. 11, no. 2, pp. 312-317, June 1996.
    • (1996) IEEE Transactions on Energy Conversion , vol.11 , Issue.2 , pp. 312-317
    • Streifel, R.J.1    Marks II, R.J.2    El-Sharkawi, M.A.3    Kerszenbaum, I.4
  • 4
    • 0035148935 scopus 로고    scopus 로고
    • Condition monitoring of brushless three-phase synchronous generators with stator winding or rotor circuit deterioration
    • Sept./Oct
    • J. Sottile, F. C. Trutt and A.W. Leedy, "Condition monitoring of brushless three-phase synchronous generators with stator winding or rotor circuit deterioration," IEEE Industry Applications Society Annual Meeting Conference, vol. 3, pp. 1587-1594, Sept./Oct. 2001.
    • (2001) IEEE Industry Applications Society Annual Meeting Conference , vol.3 , pp. 1587-1594
    • Sottile, J.1    Trutt, F.C.2    Leedy, A.W.3
  • 5
    • 0028496220 scopus 로고    scopus 로고
    • J. S. Hsu (Htsui) and J. Stein, Shaft signals of salient-pole synchronous machines for eccentricity and shorted-field-coil detections, IEEE Transactions on Energy Conversion, 9, no. 3, pp. 572-578, Sept. 1994.
    • J. S. Hsu (Htsui) and J. Stein, "Shaft signals of salient-pole synchronous machines for eccentricity and shorted-field-coil detections," IEEE Transactions on Energy Conversion, vol. 9, no. 3, pp. 572-578, Sept. 1994.
  • 6
    • 84947283667 scopus 로고    scopus 로고
    • Broken Damper Bar Detection Studies Using Flux Probe Measurements and Time-Stepping Finite Element Analysis For Salient-Pole Synchronous Machines
    • Aug
    • H. C. Karmaker, "Broken Damper Bar Detection Studies Using Flux Probe Measurements and Time-Stepping Finite Element Analysis For Salient-Pole Synchronous Machines," SDEMPED 2003 - Symposium on Diagnostics far Electric Machines, Power Electronics and Driven, vol. 9, no. 3, pp. 193-197, Aug. 2003.
    • (2003) SDEMPED 2003 - Symposium on Diagnostics far Electric Machines, Power Electronics and Driven , vol.9 , Issue.3 , pp. 193-197
    • Karmaker, H.C.1
  • 7
    • 33645292151 scopus 로고    scopus 로고
    • Detection of stator inter-turn faults in reluctance synchronous motor by using stored magnetic energy after supply disconnection
    • Kharagpur, India, Dec. 21-23
    • P. Neti and S. Nandi,, "Detection of stator inter-turn faults in reluctance synchronous motor by using stored magnetic energy after supply disconnection," in Proc. 2nd Nat. Power Electronics Conf., Kharagpur, India, Dec. 21-23, 2005, pp. 45-48.
    • (2005) Proc. 2nd Nat. Power Electronics Conf , pp. 45-48
    • Neti, P.1    Nandi, S.2
  • 10
    • 34948841553 scopus 로고    scopus 로고
    • Stator Inter-turn Fault Detection of Synchronous Machines Using Field Current Signature Analysis
    • Oct
    • P. Neti, S. Nandi, "Stator Inter-turn Fault Detection of Synchronous Machines Using Field Current Signature Analysis", IEEE Industry Applications Conference, vol 5, pp. 2360-2367, Oct 2006.
    • (2006) IEEE Industry Applications Conference , vol.5 , pp. 2360-2367
    • Neti, P.1    Nandi, S.2
  • 11
    • 0024121951 scopus 로고
    • Noninvasive detection of broken bars in operating induction motors
    • Dec
    • G. B. Kliman, R. A. Koegl, J. Stein, R. D. Endicott and M. W. Madden, "Noninvasive detection of broken bars in operating induction motors," IEEE Trans. Energy Conv,, vol. 3, no.4, pp. 873-879, Dec. 1988.
    • (1988) IEEE Trans. Energy Conv , vol.3 , Issue.4 , pp. 873-879
    • Kliman, G.B.1    Koegl, R.A.2    Stein, J.3    Endicott, R.D.4    Madden, M.W.5
  • 12
    • 0032097875 scopus 로고    scopus 로고
    • A novel method for modeling dynamic air-gap eccentricity in synchronous machines based on modified winding function theory
    • June
    • N.A. Al-Nuaim and H.A. Toliyat, "A novel method for modeling dynamic air-gap eccentricity in synchronous machines based on modified winding function theory," IEEE Trans. On Energy Conversion, vol. 13, no.2, pp. 156-162, June 1998.
    • (1998) IEEE Trans. On Energy Conversion , vol.13 , Issue.2 , pp. 156-162
    • Al-Nuaim, N.A.1    Toliyat, H.A.2
  • 13
    • 0030189294 scopus 로고    scopus 로고
    • A method for dynamic simulation of air-gap eccentricity in induction machines
    • July/Aug
    • H.A. Toliyat, M.S. Arefeen and A.G. Parlos, "A method for dynamic simulation of air-gap eccentricity in induction machines," IEEE Trans. Industry Applications, vol. 32, no.4, pp. 910-918, July/Aug. 1996.
    • (1996) IEEE Trans. Industry Applications , vol.32 , Issue.4 , pp. 910-918
    • Toliyat, H.A.1    Arefeen, M.S.2    Parlos, A.G.3
  • 14
    • 0029344878 scopus 로고
    • Effects of time-varying loads on rotor fault detection in induction machines
    • July/August
    • R. R. Schoen, T. G. Habetler, " Effects of time-varying loads on rotor fault detection in induction machines," IEEE Transactions on Industry Applications, vol. 31, no. 4, pp. 900-906, July/August 1995.
    • (1995) IEEE Transactions on Industry Applications , vol.31 , Issue.4 , pp. 900-906
    • Schoen, R.R.1    Habetler, T.G.2