메뉴 건너뛰기




Volumn 40, Issue 4, 2008, Pages 183-213

Textile-structured electrodes for electrocardiogram

Author keywords

Bioelectricity; Contact resistance; Electrocardiogram; Fabric electrode; Impedance; Nernst equation

Indexed keywords

DISPOSABLE PRODUCT; ELECTROLYTE; HYDROGEL; INDUSTRIAL TEXTILE; MEDICAL USE; STRUCTURAL PROPERTY; WEAVABILITY;

EID: 57749177971     PISSN: 00405167     EISSN: 17542278     Source Type: Trade Journal    
DOI: 10.1080/00405160802597479     Document Type: Article
Times cited : (132)

References (57)
  • 4
    • 33645541181 scopus 로고
    • Experimental Results Relating to the Rhythmical and Excitatory Motions of the Ventricle of the Heart of the Frog, and of the Electrical Phenomena Which Accompany Them
    • J. Burdon Sanderson and F.J.M. Page, Experimental Results Relating to the Rhythmical and Excitatory Motions of the Ventricle of the Heart of the Frog, and of the Electrical Phenomena Which Accompany Them, Proceedings of the Royal Society of London 27 (1878), p.410-414.
    • (1878) Proceedings of the Royal Society of London , vol.27 , pp. 410-414
    • Burdon Sanderson, J.1    Page, F.J.M.2
  • 12
    • 33846935267 scopus 로고    scopus 로고
    • Conductive rubber electrode for wearable health monitoring
    • Engineering in Medicine and Biology Society, Vols
    • C.Y Ryu, S.H. Nam, and S. Kim, Conductive rubber electrode for wearable health monitoring, 27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-7 (2005), p.3479-3481.
    • (2005) 27th Annual International Conference of the IEEE , vol.1-7 , pp. 3479-3481
    • Ryu, C.Y.1    Nam, S.H.2    Kim, S.3
  • 13
    • 11144283609 scopus 로고    scopus 로고
    • Dry electrodes for monitoring of vital signs in functional textiles
    • Engineering in Medicine and Biology Society, Vols
    • J. Muhlsteff and O. Such, Dry electrodes for monitoring of vital signs in functional textiles, Proceedings of the 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-7 (26) (2004), p.2212-2215.
    • (2004) Proceedings of the 26th Annual International Conference of the IEEE , vol.1-7 , Issue.26 , pp. 2212-2215
    • Muhlsteff, J.1    Such, O.2
  • 14
    • 84903861440 scopus 로고    scopus 로고
    • Flexible dry surface-electrodes for ECG long-term monitoring
    • Engineering in Medicine and Biology Society, Vols
    • K.P. Hoffmann and R. Ruff, Flexible dry surface-electrodes for ECG long-term monitoring, 2007 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-16 (2007), p.5740-5743.
    • (2007) 2007 Annual International Conference of the IEEE , vol.1-16 , pp. 5740-5743
    • Hoffmann, K.P.1    Ruff, R.2
  • 20
    • 33749075142 scopus 로고    scopus 로고
    • S.M. Lobodzinski and M.M. Laks, J. Electrocardio.39 (2006), p.S41-S46.
    • S.M. Lobodzinski and M.M. Laks, J. Electrocardio.39 (2006), p.S41-S46.
  • 32
    • 57749192599 scopus 로고    scopus 로고
    • ANSI/AAMI EC12:2000, Disposable ECG electrode, Association for the Advancement of Medical Instrument, Arlington, US, 2000.
    • ANSI/AAMI EC12:2000, Disposable ECG electrode, Association for the Advancement of Medical Instrument, Arlington, US, 2000.
  • 33
    • 57749199410 scopus 로고    scopus 로고
    • R. Matthews, N.J. McDonald, I. Fridman, P. Hervieux and T. Nielsen, Found. Augmented Cog. 11 (2005), p.221-230.
    • R. Matthews, N.J. McDonald, I. Fridman, P. Hervieux and T. Nielsen, Found. Augmented Cog. 11 (2005), p.221-230.
  • 36
    • 57749185583 scopus 로고    scopus 로고
    • R.a.O. Cooper, J.W. and Shaw, J.C., EEG Technology, Butterworths, London, 1980.
    • R.a.O. Cooper, J.W. and Shaw, J.C., EEG Technology, Butterworths, London, 1980.
  • 37
    • 57749185149 scopus 로고    scopus 로고
    • W.E. Morton and J.W.S. Hearle, Physical Properties of Textile Fibres, 3rd edition Textil. Res. J., 1993.
    • W.E. Morton and J.W.S. Hearle, Physical Properties of Textile Fibres, 3rd edition Textil. Res. J., 1993.
  • 39
    • 36849094078 scopus 로고    scopus 로고
    • L. Rattfalt, M. Linden, P. Hult, L. Berglin, and P. Ask, MedBiol. Eng. Comput. 45 (2007), p.1251-1257.
    • L. Rattfalt, M. Linden, P. Hult, L. Berglin, and P. Ask, MedBiol. Eng. Comput. 45 (2007), p.1251-1257.
  • 48
    • 33845232222 scopus 로고    scopus 로고
    • Electrically conductive yarns based on PVA/carbon nanotubes
    • P. Xue, K.H. Park, X.M. Tao, W. Chen, and X.Y. Cheng, Electrically conductive yarns based on PVA/carbon nanotubes, Comp. Struct. 78 (2007), p.271-277.
    • (2007) Comp. Struct , vol.78 , pp. 271-277
    • Xue, P.1    Park, K.H.2    Tao, X.M.3    Chen, W.4    Cheng, X.Y.5
  • 50
    • 46649091717 scopus 로고    scopus 로고
    • G. Priniotakis, P. Westbroek, L. Van Langenhove, and C. Hertleer, Trans. Inst. Meas. Contr. 29 (2007)p.271-281.
    • G. Priniotakis, P. Westbroek, L. Van Langenhove, and C. Hertleer, Trans. Inst. Meas. Contr. 29 (2007)p.271-281.
  • 51
    • 4344619976 scopus 로고    scopus 로고
    • M. Catrysse, R. Puers, C. Hertleer, L. Van Langenhove, H. Van Egmond, and D. Matthys, Sensor. Actuator. Phys. 114 (2004), p.302-311.
    • M. Catrysse, R. Puers, C. Hertleer, L. Van Langenhove, H. Van Egmond, and D. Matthys, Sensor. Actuator. Phys. 114 (2004), p.302-311.
  • 53
    • 31144476163 scopus 로고    scopus 로고
    • H. Zhang, X.M. Tao, T.X. Yu, and S.Y. Wang, Sensor. Actuator. Phys. 126 (2006), p.129-140.
    • H. Zhang, X.M. Tao, T.X. Yu, and S.Y. Wang, Sensor. Actuator. Phys. 126 (2006), p.129-140.