메뉴 건너뛰기




Volumn 385, Issue 1, 2009, Pages 184-186

A facile strategy for nonenzymatic glucose detection

Author keywords

[No Author keywords available]

Indexed keywords

CHEMICAL DETECTION; CORRELATION DETECTORS; GLASS MEMBRANE ELECTRODES; GLUCOSE; GLUCOSE SENSORS; MULTIWALLED CARBON NANOTUBES (MWCN); PH; PHYSIOLOGICAL MODELS; SIGNAL TO NOISE RATIO;

EID: 57749176389     PISSN: 00032697     EISSN: 10960309     Source Type: Journal    
DOI: 10.1016/j.ab.2008.11.004     Document Type: Article
Times cited : (5)

References (12)
  • 1
    • 14844322860 scopus 로고    scopus 로고
    • Rapid monitoring of diabetes-induced lipid peroxidation by Fourier transform infrared spectroscopy: Evidence from rat liver microsomal membranes
    • Severcan F., Gorgulu G., Gorgulu S.T., and Guray T. Rapid monitoring of diabetes-induced lipid peroxidation by Fourier transform infrared spectroscopy: Evidence from rat liver microsomal membranes. Anal. Biochem. 339 (2005) 36-40
    • (2005) Anal. Biochem. , vol.339 , pp. 36-40
    • Severcan, F.1    Gorgulu, G.2    Gorgulu, S.T.3    Guray, T.4
  • 2
    • 0035021705 scopus 로고    scopus 로고
    • Sensors for glucose monitoring: technical and clinical aspects
    • Koschinsky T., and Heinemann L. Sensors for glucose monitoring: technical and clinical aspects. Diabetes/Metab. Res. Rev. 17 (2001) 113-123
    • (2001) Diabetes/Metab. Res. Rev. , vol.17 , pp. 113-123
    • Koschinsky, T.1    Heinemann, L.2
  • 3
    • 29944443113 scopus 로고    scopus 로고
    • Electrochemical non-enzymatic glucose sensors
    • Park S., Boo H., and Chung T.D. Electrochemical non-enzymatic glucose sensors. Anal. Chim. Acta 556 (2006) 46-57
    • (2006) Anal. Chim. Acta , vol.556 , pp. 46-57
    • Park, S.1    Boo, H.2    Chung, T.D.3
  • 4
    • 41649096945 scopus 로고    scopus 로고
    • In vivo glucose monitoring: towards 'Sense and Act' feedback-loop individualized medical systems
    • Wang J. In vivo glucose monitoring: towards 'Sense and Act' feedback-loop individualized medical systems. Talanta 75 (2008) 636-641
    • (2008) Talanta , vol.75 , pp. 636-641
    • Wang, J.1
  • 5
    • 34548185865 scopus 로고    scopus 로고
    • A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes
    • Kang X.H., Mai Z.B., Zou X.Y., Cai P.X., and Mo J.Y. A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes. Anal. Biochem. 369 (2007) 71-79
    • (2007) Anal. Biochem. , vol.369 , pp. 71-79
    • Kang, X.H.1    Mai, Z.B.2    Zou, X.Y.3    Cai, P.X.4    Mo, J.Y.5
  • 6
    • 39349110002 scopus 로고    scopus 로고
    • A modified glassy carbon electrode for hydrogen peroxide sensing
    • Zheng C.Y., Chen S.H., Shang Y.J., and Li M.G. A modified glassy carbon electrode for hydrogen peroxide sensing. Ann. Chim. Rome 97 (2007) 1227-1235
    • (2007) Ann. Chim. Rome , vol.97 , pp. 1227-1235
    • Zheng, C.Y.1    Chen, S.H.2    Shang, Y.J.3    Li, M.G.4
  • 7
    • 19444364420 scopus 로고    scopus 로고
    • Effect of Ag nanoparticles for electrochemical sensing of Brilliant Cresyl Blue
    • Li M.G., Gao Y.C., Kan X.W., Wang G.F., and Fang B. Effect of Ag nanoparticles for electrochemical sensing of Brilliant Cresyl Blue. Chem. Lett. 34 (2005) 386-387
    • (2005) Chem. Lett. , vol.34 , pp. 386-387
    • Li, M.G.1    Gao, Y.C.2    Kan, X.W.3    Wang, G.F.4    Fang, B.5
  • 9
    • 24644479720 scopus 로고    scopus 로고
    • Silicon nanowire sensors for bioanalytical applications: glucose and hydrogen peroxide detection
    • Shao M.W., Shan Y.Y., Wong N.B., and Lee S.T. Silicon nanowire sensors for bioanalytical applications: glucose and hydrogen peroxide detection. Adv. Funct. Mater. 15 (2005) 1478-1482
    • (2005) Adv. Funct. Mater. , vol.15 , pp. 1478-1482
    • Shao, M.W.1    Shan, Y.Y.2    Wong, N.B.3    Lee, S.T.4
  • 10
    • 84990009980 scopus 로고
    • Fluorescent chemosensors of carbohydrates. A means of chemically communicating the binding of polyols in water based on chelation-enhanced quenching
    • Yoon J., and Czarnik A.W. Fluorescent chemosensors of carbohydrates. A means of chemically communicating the binding of polyols in water based on chelation-enhanced quenching. J. Am. Chem. Soc. 114 (1992) 5874-5875
    • (1992) J. Am. Chem. Soc. , vol.114 , pp. 5874-5875
    • Yoon, J.1    Czarnik, A.W.2
  • 11
    • 0018915879 scopus 로고
    • The electrooxidation of glucose in phosphate buffer solutions: kinetics and reaction mechanism
    • Ernst S., Heitbaum J., and Hamann C.H. The electrooxidation of glucose in phosphate buffer solutions: kinetics and reaction mechanism. Ber. Bunsen-Ges. Phys. Chem. 84 (1980) 50-55
    • (1980) Ber. Bunsen-Ges. Phys. Chem. , vol.84 , pp. 50-55
    • Ernst, S.1    Heitbaum, J.2    Hamann, C.H.3
  • 12
    • 0002730511 scopus 로고
    • A comparative study of Prussian-blue-modified graphite paste electrodes and solid graphite electrodes with mechanically immobilized Prussian blue
    • Zakharchuk N.F., Meyer B., Henning H., Scholz F., Jaworsi A., and Stojek Z. A comparative study of Prussian-blue-modified graphite paste electrodes and solid graphite electrodes with mechanically immobilized Prussian blue. J. Electroanal. Chem. 398 (1995) 23-35
    • (1995) J. Electroanal. Chem. , vol.398 , pp. 23-35
    • Zakharchuk, N.F.1    Meyer, B.2    Henning, H.3    Scholz, F.4    Jaworsi, A.5    Stojek, Z.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.