Volumn 79, Issue 6, 2008, Pages 755-762

Less range of motion with resurfacing arthroplasty than with total hip arthroplasty: In vitro examination of 8 designs

Author keywords

[No Author keywords available]

Indexed keywords

POLYETHYLENE;

EID: 57749117201     PISSN: 17453674     EISSN: 17453682     Source Type: Journal    
DOI: 10.1080/17453670810016812     Document Type: Article
Times cited : (35)

References (15)
  • 1
    • 57749103737 scopus 로고    scopus 로고
    • Dislocation after revision total hip arthroplasty: An analysis of risk factors and treatment options
    • Alberton G M, High W A, Morrey B F. Dislocation after revision total hip arthroplasty: an analysis of risk factors and treatment options. J Bone Joint Surg (Am) 2004; 12 (5): 314-21
    • (2004) J Bone Joint Surg (Am) , vol.12 , Issue.5 , pp. 314-321
    • Alberton, G.M.1    High, W.A.2    Morrey, B.F.3
  • 3
    • 0016707369 scopus 로고
    • Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus
    • Amstutz H C, Lodwig R M, Schurman D J, Hodgson A G. Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus. Clin Orthop 1975; (111): 124-30.
    • (1975) Clin Orthop , vol.111 , pp. 124-130
    • Amstutz, H.C.1    Lodwig, R.M.2    Schurman, D.J.3    Hodgson, A.G.4
  • 4
    • 0031862869 scopus 로고    scopus 로고
    • Evolution and future of surface replacement of the hip
    • Amstutz H C, Grigoris P, Dorey F J. Evolution and future of surface replacement of the hip. J Orthop Sci 1998; 3: 169-86.
    • (1998) J Orthop Sci , vol.3 , pp. 169-186
    • Amstutz, H.C.1    Grigoris, P.2    Dorey, F.J.3
  • 5
    • 4444309697 scopus 로고    scopus 로고
    • The influence of head and neck geometry on stability of total hip replacement
    • Bader R, Scholtz R, Steinhauser E, et al. The influence of head and neck geometry on stability of total hip replacement. Acta Orthopaedica 2004; 75 4: 415-21.
    • (2004) Acta Orthopaedica , vol.75 , Issue.4 , pp. 415-421
    • Bader, R.1    Scholtz, R.2    Steinhauser, E.3
  • 6
    • 34147142943 scopus 로고    scopus 로고
    • Early results of conversion of a failed femoral component in hip resurfacing arthroplasty
    • Ball S T, Le Duff M J, Amstutz H C. Early results of conversion of a failed femoral component in hip resurfacing arthroplasty. J Bone Joint Surg (Am) 2007; 89 (4): 735-41.
    • (2007) J Bone Joint Surg (Am) , vol.89 , Issue.4 , pp. 735-741
    • Ball, S.T.1    Le Duff, M.J.2    Amstutz, H.C.3
  • 7
    • 0037822087 scopus 로고    scopus 로고
    • Barrack R L. Dislocation after total hip arthroplasty: implant design and orientation. Review. J Am Acad Orthop Surg 2003; 11 (2): 89-99.
    • Barrack R L. Dislocation after total hip arthroplasty: implant design and orientation. Review. J Am Acad Orthop Surg 2003; 11 (2): 89-99.
  • 9
    • 0030131155 scopus 로고    scopus 로고
    • Cristofolini L, Viceconti M, Cappello A, Toni A. Mechanical validation of whole bone composite femur models. Review. J Biomech 1996; 29 (4): 525-35.
    • Cristofolini L, Viceconti M, Cappello A, Toni A. Mechanical validation of whole bone composite femur models. Review. J Biomech 1996; 29 (4): 525-35.
  • 10
    • 28944445047 scopus 로고    scopus 로고
    • Dual energy X-ray absorptiometry analysis of peri-prosthetic stress shielding in the Birmingham resurfacing hip replacement
    • Epub Oct 20
    • Harty J A, Devitt B, Harty L C, Molloy M, McGuinness A. Dual energy X-ray absorptiometry analysis of peri-prosthetic stress shielding in the Birmingham resurfacing hip replacement. Arch Orthop Trauma Surg 2005; 125 (10): 693-5. Epub 2005 Oct 20.
    • (2005) Arch Orthop Trauma Surg 2005 , vol.125 , Issue.10 , pp. 693-695
    • Harty, J.A.1    Devitt, B.2    Harty, L.C.3    Molloy, M.4    McGuinness, A.5
  • 11
    • 0025276954 scopus 로고
    • Wagner resurfacing hip arthroplasty. The results of one hundred consecutive arthroplasties after 8 to 10 years
    • Howie D W, Campbell D, McGee M, et al. Wagner resurfacing hip arthroplasty. The results of one hundred consecutive arthroplasties after 8 to 10 years. J Bone Joint Surg (Am) 1990; 72: 708-14.
    • (1990) J Bone Joint Surg (Am) , vol.72 , pp. 708-714
    • Howie, D.W.1    Campbell, D.2    McGee, M.3
  • 12
  • 13
    • 0001566619 scopus 로고    scopus 로고
    • Rieker C B, Kottig P, Schon R, et al. Clinical wear performance of metal-on-metal hip arthroplasties. In: Alternative bearing surfaces in total joint replacements (eds. Jacobs J, Craig T, L). ASTM, Conshohocken 1998: 144.
    • Rieker C B, Kottig P, Schon R, et al. Clinical wear performance of metal-on-metal hip arthroplasties. In: Alternative bearing surfaces in total joint replacements (eds. Jacobs J, Craig T, L). ASTM, Conshohocken 1998: 144.
  • 14
    • 0038476315 scopus 로고    scopus 로고
    • Walking patterns of hip arthroplasty patients: Some observations on the medio-lateral excursions of the trunk
    • Vogt L, Brettmann K, Pfeifer K, Banzer W. Walking patterns of hip arthroplasty patients: some observations on the medio-lateral excursions of the trunk. Disabil Rehabil 2003; 25 (7): 309-17.
    • (2003) Disabil Rehabil , vol.25 , Issue.7 , pp. 309-317
    • Vogt, L.1    Brettmann, K.2    Pfeifer, K.3    Banzer, W.4
  • 15
    • 0035212605 scopus 로고    scopus 로고
    • Pelvic and lower limb compensatory actions of subjects in an early stage of hip osteoarthritis
    • Watelain E, Dujardin F, Babier F, Dubois D, Allard P. Pelvic and lower limb compensatory actions of subjects in an early stage of hip osteoarthritis. Arch Phys Med Rehabil 2001; 82 (12): 1705-11.
    • (2001) Arch Phys Med Rehabil , vol.82 , Issue.12 , pp. 1705-1711
    • Watelain, E.1    Dujardin, F.2    Babier, F.3    Dubois, D.4    Allard, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.