메뉴 건너뛰기




Volumn 40, Issue 10, 2008, Pages 680-687

Ultrasound guidance and monitoring of laser-based fat removal

Author keywords

Body reshaping; Fat removal; Laser therapy; Thermal imaging; Treatment monitoring; Ultrasound imaging

Indexed keywords

LIPID; WATER;

EID: 57749094847     PISSN: 01968092     EISSN: 10969101     Source Type: Journal    
DOI: 10.1002/lsm.20726     Document Type: Article
Times cited : (4)

References (31)
  • 1
    • 85148991389 scopus 로고    scopus 로고
    • Heymans O, Castus P, Grandjean FX, Van Zele D. Liposuction: Review of the techniques, innovations and applications. Acta Chir Belg 2006;106(6):647-653.
    • Heymans O, Castus P, Grandjean FX, Van Zele D. Liposuction: Review of the techniques, innovations and applications. Acta Chir Belg 2006;106(6):647-653.
  • 3
    • 33645671728 scopus 로고    scopus 로고
    • Submental Nd:Yag laser-assisted liposuction
    • Alberto G. Submental Nd:Yag laser-assisted liposuction. Lasers Surg Med 2006;38(3):181-184.
    • (2006) Lasers Surg Med , vol.38 , Issue.3 , pp. 181-184
    • Alberto, G.1
  • 4
    • 37249092467 scopus 로고    scopus 로고
    • The new laser liposuction for men
    • Katz B, McBean J. The new laser liposuction for men. Dermatol Ther 2008;20(6):448-451.
    • (2008) Dermatol Ther , vol.20 , Issue.6 , pp. 448-451
    • Katz, B.1    McBean, J.2
  • 5
    • 31044437564 scopus 로고    scopus 로고
    • Complications of body sculpture: Prevention and treatment
    • v
    • Toledo LS, Mauad R. Complications of body sculpture: Prevention and treatment. Clin Plast Surg 2006;33(1):1-11, v.
    • (2006) Clin Plast Surg , vol.33 , Issue.1 , pp. 1-11
    • Toledo, L.S.1    Mauad, R.2
  • 6
    • 48049119512 scopus 로고    scopus 로고
    • Major and lethal complications of liposuction: A review of 72 cases in Germany between 1998 and 2002
    • Lehnhardt M, Homann HH, Daigeler A, Hauser J, Palka P, Steinau HU. Major and lethal complications of liposuction: A review of 72 cases in Germany between 1998 and 2002. Plast Reconstr Surg 2008;121(6):396e-403e.
    • (2008) Plast Reconstr Surg , vol.121 , Issue.6
    • Lehnhardt, M.1    Homann, H.H.2    Daigeler, A.3    Hauser, J.4    Palka, P.5    Steinau, H.U.6
  • 9
    • 0025127733 scopus 로고
    • Study of subcutaneous fat
    • Illouz YG. Study of subcutaneous fat. Aesthetic Plast Surg 1990;14(1):165-177.
    • (1990) Aesthetic Plast Surg , vol.14 , Issue.1 , pp. 165-177
    • Illouz, Y.G.1
  • 10
    • 0026178989 scopus 로고
    • Pathologic analysis of photothermal and photomechanical effects of laser-tissue interactions
    • Thomsen S. Pathologic analysis of photothermal and photomechanical effects of laser-tissue interactions. Photochem Photobiol 1991;53(6):825-835.
    • (1991) Photochem Photobiol , vol.53 , Issue.6 , pp. 825-835
    • Thomsen, S.1
  • 12
    • 0028823285 scopus 로고
    • Ovarian cancer screening. The role of ultrasound in early detection
    • Karlan BY, Platt LD. Ovarian cancer screening. The role of ultrasound in early detection. Cancer 1995;76:2011-2015.
    • (1995) Cancer , vol.76 , pp. 2011-2015
    • Karlan, B.Y.1    Platt, L.D.2
  • 13
    • 0032033438 scopus 로고    scopus 로고
    • The role of ultrasound in breast cancer screening. A consensus statement by the European Group for breast cancer screening
    • Teh W, Wilson ARM. The role of ultrasound in breast cancer screening. A consensus statement by the European Group for breast cancer screening. Eur J Cancer 1998;34(4):449-450.
    • (1998) Eur J Cancer , vol.34 , Issue.4 , pp. 449-450
    • Teh, W.1    Wilson, A.R.M.2
  • 14
    • 0442279553 scopus 로고    scopus 로고
    • Ultrasound characterization of coronary artery wall in vitro using temperature-dependent wave speed. Ultrasonics, Ferroelectrics and Frequency Control
    • Pereira FR, Machado JC, Foster FS. Ultrasound characterization of coronary artery wall in vitro using temperature-dependent wave speed. Ultrasonics, Ferroelectrics and Frequency Control. IEEE Transactions on 2003; 50(11):1474-1485.
    • (2003) IEEE Transactions on , vol.50 , Issue.11 , pp. 1474-1485
    • Pereira, F.R.1    Machado, J.C.2    Foster, F.S.3
  • 18
    • 41149122796 scopus 로고    scopus 로고
    • Ultrasound imaging to monitor photothermal therapy - Feasibility study
    • Shah J, Aglyamov SR, Sokolov K, Milner TE, Emelianov SY. Ultrasound imaging to monitor photothermal therapy - Feasibility study. Opt Express 2008;16(6):3776-3785.
    • (2008) Opt Express , vol.16 , Issue.6 , pp. 3776-3785
    • Shah, J.1    Aglyamov, S.R.2    Sokolov, K.3    Milner, T.E.4    Emelianov, S.Y.5
  • 21
    • 0029798475 scopus 로고    scopus 로고
    • Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part I. Analytical model
    • Maass-Moreno R, Damianou CA. Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part I. Analytical model. J Acoust Soc Am 1996;100(4 Pt 1):2514-2521.
    • (1996) J Acoust Soc Am , vol.100 , Issue.4 PART 1 , pp. 2514-2521
    • Maass-Moreno, R.1    Damianou, C.A.2
  • 22
    • 0029794863 scopus 로고    scopus 로고
    • Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part II. In vitro study
    • Maass-Moreno R, Damianou CA, Sanghvi NT. Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part II. In vitro study. J Acoust Soc Am 1996;100(4 Pt 1):2522-2530.
    • (1996) J Acoust Soc Am , vol.100 , Issue.4 PART 1 , pp. 2522-2530
    • Maass-Moreno, R.1    Damianou, C.A.2    Sanghvi, N.T.3
  • 24
    • 0018600264 scopus 로고
    • Ultrasonic attenuation and propagation speed in mammalian tissues as a function of temperature
    • Bamber JC, Hill CR. Ultrasonic attenuation and propagation speed in mammalian tissues as a function of temperature. Ultrasound Med Biol 1979;5:149-157.
    • (1979) Ultrasound Med Biol , vol.5 , pp. 149-157
    • Bamber, J.C.1    Hill, C.R.2
  • 25
    • 0032785966 scopus 로고    scopus 로고
    • Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation. Ultrasonics, Ferroelectrics and Frequency Control
    • Lubinski MA, Emelianov SY, O'Donnell M. Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation. Ultrasonics, Ferroelectrics and Frequency Control. IEEE Transactions on 1999; 46(1): 82-96.
    • (1999) IEEE Transactions on , vol.46 , Issue.1 , pp. 82-96
    • Lubinski, M.A.1    Emelianov, S.Y.2    O'Donnell, M.3
  • 26
    • 0001066551 scopus 로고    scopus 로고
    • Spatially selective photocoagulation of biological tissues: Feasibility study utilizing cryogen spray cooling
    • Anvari B, Tanenbaum BS, Milner TE, Tang K, Liaw L-H, Kalafus K, Kimel S, Nelson JS. Spatially selective photocoagulation of biological tissues: Feasibility study utilizing cryogen spray cooling. Appl Opt 1996;35(19):3314- 3320.
    • (1996) Appl Opt , vol.35 , Issue.19 , pp. 3314-3320
    • Anvari, B.1    Tanenbaum, B.S.2    Milner, T.E.3    Tang, K.4    Liaw, L.-H.5    Kalafus, K.6    Kimel, S.7    Nelson, J.S.8
  • 27
    • 0141717606 scopus 로고    scopus 로고
    • Practical pathology for engineers: How to do the job right the first time
    • Thomsen SL. Practical pathology for engineers: How to do the job right the first time. Proc SPIE 2003;4954(1):476635.
    • (2003) Proc SPIE , vol.4954 , Issue.1 , pp. 476635
    • Thomsen, S.L.1
  • 28
    • 34247375495 scopus 로고    scopus 로고
    • Photoacoustic imaging of the microvasculature with a high-frequency ultrasound array transducer
    • Zemp RJ, Bitton R, Li M-L, Shung KK, Stoica G, Wang LV. Photoacoustic imaging of the microvasculature with a high-frequency ultrasound array transducer. J Biomed Opt 2007;12(1):010501.
    • (2007) J Biomed Opt , vol.12 , Issue.1 , pp. 010501
    • Zemp, R.J.1    Bitton, R.2    Li, M.-L.3    Shung, K.K.4    Stoica, G.5    Wang, L.V.6
  • 30
    • 0029347489 scopus 로고
    • Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound
    • Seip R, Ebbini ES. Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound. Biomed Eng IEEE Trans 1995;42(8):828-839.
    • (1995) Biomed Eng IEEE Trans , vol.42 , Issue.8 , pp. 828-839
    • Seip, R.1    Ebbini, E.S.2
  • 31
    • 0032226249 scopus 로고    scopus 로고
    • Motion compensation algorithm for noninvasive two-dimensional temperature estimation using diagnostic pulse-echo ultrasound
    • Simon C, VanBaren PD, Ebbini ES. Motion compensation algorithm for noninvasive two-dimensional temperature estimation using diagnostic pulse-echo ultrasound. SPIE Surg Appl Energy 1998;3249:182-192.
    • (1998) SPIE Surg Appl Energy , vol.3249 , pp. 182-192
    • Simon, C.1    VanBaren, P.D.2    Ebbini, E.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.