메뉴 건너뛰기




Volumn , Issue , 2007, Pages 2677-2680

Effect of self-assembled monolayers (SAMs) in binding glucose oxidase for electro-enzymatic glucose sensor with gold electrodes

Author keywords

[No Author keywords available]

Indexed keywords

ENZYME ACTIVITY; GLUCOSE OXIDASE; GOLD; SELF ASSEMBLED MONOLAYERS;

EID: 57649237727     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4352880     Document Type: Conference Paper
Times cited : (3)

References (9)
  • 1
    • 0031752685 scopus 로고    scopus 로고
    • Global burden of diabetes, 1995-2025: Prevalence, numerical estimates and projections
    • King, H., Aubert, R.E., Herman, W.H., "Global burden of diabetes, 1995-2025: prevalence, numerical estimates and projections" Diab. Care, vol. 21, pp. 1414-1431, 1998.
    • (1998) Diab. Care , vol.21 , pp. 1414-1431
    • King, H.1    Aubert, R.E.2    Herman, W.H.3
  • 2
    • 38049073055 scopus 로고
    • Pickup I C and Williams G ed, vols & 2, Dudon: Blackwell
    • Pickup I C and Williams G (ed), A Text book of Diabetes vols 1 & 2, Dudon: Blackwell, 1990.
    • (1990) A Text book of Diabetes , vol.1
  • 3
    • 38049058152 scopus 로고
    • The effect of intensive treatment of diabetes on the long-term complications in insulin dependent diabetes
    • Diabetes Control and Complication Trial Research Group
    • Diabetes Control and Complication Trial Research Group, "The effect of intensive treatment of diabetes on the long-term complications in insulin dependent diabetes", New Ens. 3. Med. 329 97746, 1993.
    • (1993) New Ens. 3. Med. 329 97746
  • 4
    • 13144307325 scopus 로고
    • Self-monitoring of blood glucose
    • ed K G M M Alberti and L P Krall (Amsterdam: Elseview) pp
    • Tatersall R B, "Self-monitoring of blood glucose", The Diabetes Annual ed K G M M Alberti and L P Krall (Amsterdam: Elseview) pp 162-77, 1985.
    • (1985) The Diabetes Annual , pp. 162-177
    • Tatersall, R.B.1
  • 5
    • 0027424767 scopus 로고
    • Blood glucose monitoring: Does technology help?
    • Page SR, Peacock I, "Blood glucose monitoring: does technology help?", Diabetic Med., vol. 10, pp 793-801, 1993.
    • (1993) Diabetic Med , vol.10 , pp. 793-801
    • Page, S.R.1    Peacock, I.2
  • 6
    • 0027284774 scopus 로고
    • Blood glucose and glycated haemoglobin measurement in hospital: Which method?
    • Pickup JC, Crook MA, Tutt P, "Blood glucose and glycated haemoglobin measurement in hospital: which method?", Diabetic Med.,vol 10, pp 402-11, 1993.
    • (1993) Diabetic Med , vol.10 , pp. 402-411
    • Pickup, J.C.1    Crook, M.A.2    Tutt, P.3
  • 7
    • 0006351420 scopus 로고
    • Membrane Polarographic Electrode System and Method with Electrochemical Compensation
    • US Patent, 3539455, Nov. 10
    • Clark L.C. Jr., "Membrane Polarographic Electrode System and Method with Electrochemical Compensation", US Patent # 3539455, Nov. 10, 1970.
    • (1970)
    • Clark Jr., L.C.1
  • 8
    • 1842431119 scopus 로고    scopus 로고
    • High-conductivity Elastomeric Electronics
    • Mar
    • DS Gray, J Tien and CS Chen, "High-conductivity Elastomeric Electronics", Adv. Mater., vol. 16, no. 5, pp. 393-397, Mar 2004.
    • (2004) Adv. Mater , vol.16 , Issue.5 , pp. 393-397
    • Gray, D.S.1    Tien, J.2    Chen, C.S.3
  • 9
    • 0036204065 scopus 로고    scopus 로고
    • Preparative two-dimentional gel electrophoresis at alkaline pH using narrow range immobilized pH gradients
    • Feb
    • S Hoving, et. al., "Preparative two-dimentional gel electrophoresis at alkaline pH using narrow range immobilized pH gradients", Proteomics, vol. 2, issue 2, pp. 127-134, Feb 2002.
    • (2002) Proteomics , vol.2 , Issue.2 , pp. 127-134
    • Hoving, S.1    et., al.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.