메뉴 건너뛰기




Volumn 3034, Issue , 1997, Pages 1017-1028

Using scout images to reduce metal artifacts in CT with application to revision total hip surgery

Author keywords

CT artifacts; Reconstruction from projections; Revision total hip replacement; ROBODOC ; Scout images

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DIGITAL IMAGE STORAGE; HIP PROSTHESES; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGING SYSTEMS; MEDICAL IMAGING; METALS; REPAIR; RESTORATION;

EID: 57649236197     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.274080     Document Type: Conference Paper
Times cited : (4)

References (14)
  • 1
    • 0019839830 scopus 로고
    • An algorithm for the reduction of metal clip artifacts in CT reconstructions
    • Nov/Dec
    • G.H. Glover and N.J. Pelc, "An algorithm for the reduction of metal clip artifacts in CT reconstructions", Medical Physics 8(6), Nov/Dec 1981, pp 799-807.
    • (1981) Medical Physics , vol.8 , Issue.6 , pp. 799-807
    • Glover, G.H.1    Pelc, N.J.2
  • 3
    • 0018349307 scopus 로고
    • Computed tomography reconstruction from hollow projections: An application to in vivo evaluation of artificial hip joints
    • Feb
    • T. Hinderling, P. Ruegsegger, M. Anliker, C. Dietschi, "Computed tomography reconstruction from hollow projections: an application to in vivo evaluation of artificial hip joints", Journal of Computer Assisted Tomography, Feb 1979, 3 (1) pp 52-57.
    • (1979) Journal of Computer Assisted Tomography , vol.3 , Issue.1 , pp. 52-57
    • Hinderling, T.1    Ruegsegger, P.2    Anliker, M.3    Dietschi, C.4
  • 4
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • Aug
    • W.A. Kalender, R. Hebel, and J. Ebersberger, "Reduction of CT artifacts caused by metallic implants." Radiology, Aug 1987, 164 (2) pp 576-7.
    • (1987) Radiology , vol.164 , Issue.2 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 6
    • 0017962169 scopus 로고
    • Image reconstruction from projections: IV: Projection completion methods (computational examples)
    • R.M. Lewitt and R.H.T., Bates, "Image reconstruction from projections: IV: Projection completion methods (computational examples)", Optik 50, 1978, pp 269-278.
    • (1978) Optik , vol.50 , pp. 269-278
    • Lewitt, R.M.1    Bates, R.H.T.2
  • 7
    • 0010980001 scopus 로고
    • Image reconstructions from limited data: Theory and applications in computerized tomography
    • Henry Stark ed, Academic Press
    • B.P. Medoff, "Image reconstructions from limited data: Theory and applications in computerized tomography", Image Recovery: Theory and Application, Henry Stark (ed), Academic Press, 1987.
    • (1987) Image Recovery: Theory and Application
    • Medoff, B.P.1
  • 8
    • 0005170559 scopus 로고
    • Reconstruction tomography from incomplete projections
    • Ter-Pogossian editor, University Park Press, Baltimore
    • B.E. Oppenheim, "Reconstruction tomography from incomplete projections", Reconstruction tomography in diagnostic and nuclear medicine, Ter-Pogossian (editor), University Park Press, Baltimore, 1977, pp. 155-183.
    • (1977) Reconstruction tomography in diagnostic and nuclear medicine , pp. 155-183
    • Oppenheim, B.E.1
  • 9
    • 57649177116 scopus 로고    scopus 로고
    • J. A. Browne, G.T. Herman, D. Odhner, SNARK93: A programming system for image reconstruction from projections Technical report MIPG198, Dept. of Radiology, University of Pennsylvania, August 1993. Mar-Apr 1988, 12 (2) pp 236-41.
    • J. A. Browne, G.T. Herman, D. Odhner, SNARK93: A programming system for image reconstruction from projections Technical report MIPG198, Dept. of Radiology, University of Pennsylvania, August 1993. Mar-Apr 1988, 12 (2) pp 236-41.
  • 10
    • 0023866456 scopus 로고
    • Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants
    • Mar-Apr
    • D.D. Robertson, P.J. Weiss, E.K. Fishman, D. Magid, P.S. Walker, "Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants", Journal of Computer Assisted Tomography, Mar-Apr 1988, 12 (2) pp 236-41.
    • (1988) Journal of Computer Assisted Tomography , vol.12 , Issue.2 , pp. 236-241
    • Robertson, D.D.1    Weiss, P.J.2    Fishman, E.K.3    Magid, D.4    Walker, P.S.5
  • 11
    • 0030313112 scopus 로고    scopus 로고
    • CT artifact correction: An image processing approach, SPIE Medical Imaging 1996
    • H. Soltanian-Zadeh, J.P. Windham, J. Soltanianzadeh "CT artifact correction: An image processing approach", SPIE Medical Imaging 1996: Image Processing, Vol 2710, 1996, pp 477-458.
    • (1996) Image Processing , vol.2710 , pp. 477-458
    • Soltanian-Zadeh, H.1    Windham, J.P.2    Soltanianzadeh, J.3
  • 12
    • 0026461212 scopus 로고
    • Algorithm to reduce clip artifacts in CT images
    • Newport Beach, CA Feb
    • H.K. Tuy, "Algorithm to reduce clip artifacts in CT images", Medical Imaging VI: Image Processing Conference, Newport Beach, CA Feb 1992, p 635-643.
    • (1992) Medical Imaging VI: Image Processing Conference , pp. 635-643
    • Tuy, H.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.