메뉴 건너뛰기




Volumn , Issue , 2007, Pages 1437-1440

Comparisons of FIR and IIR implementations of a subtraction-based stimulus artifact rejection algorithm

Author keywords

[No Author keywords available]

Indexed keywords

FINITE IMPULSE RESPONSE (FIR); INFINITE IMPULSE RESPONSE (IIR); STIMULUS ARTIFACT REJECTION (SAR) ALGORITHMS; TEMPORAL FILTERING TECHNIQUES;

EID: 57649233196     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4352570     Document Type: Conference Paper
Times cited : (7)

References (7)
  • 1
    • 0037196235 scopus 로고    scopus 로고
    • A template subtraction method for stimulus artifact removal in high-frequency deep brain stimulation
    • T. Hashimoto, C. M. Elder, and J. L. Vitek, "A template subtraction method for stimulus artifact removal in high-frequency deep brain stimulation," J. Neurosci. Meth., vol. 113, pp. 181-186, 2002.
    • (2002) J. Neurosci. Meth , vol.113 , pp. 181-186
    • Hashimoto, T.1    Elder, C.M.2    Vitek, J.L.3
  • 2
    • 0037201958 scopus 로고    scopus 로고
    • Real-time multichannel stimulus artifact suppression by local curve fitting
    • October
    • D. A. Wagenaar and S. M. Potter, "Real-time multichannel stimulus artifact suppression by local curve fitting," J. Neurosci. Meth., vol. 120, no. 2, pp. 17-24, October 2002.
    • (2002) J. Neurosci. Meth , vol.120 , Issue.2 , pp. 17-24
    • Wagenaar, D.A.1    Potter, S.M.2
  • 3
    • 0036086083 scopus 로고    scopus 로고
    • Stimulus artifact cancellation in the serosal recordings of gastric myoelectric activity using wavelet transform
    • July
    • H. Liang and Z. Lin, "Stimulus artifact cancellation in the serosal recordings of gastric myoelectric activity using wavelet transform," IEEE Trans. Biomed. Eng., vol. 49, no. 7, pp. 681-688, July 2002.
    • (2002) IEEE Trans. Biomed. Eng , vol.49 , Issue.7 , pp. 681-688
    • Liang, H.1    Lin, Z.2
  • 4
    • 0028108403 scopus 로고
    • Instrumentation for ENG and EMG recordings in FES systems
    • July
    • Z. M. Nikolic et al., "Instrumentation for ENG and EMG recordings in FES systems," IEEE Trans. Biomed. Eng., vol. 41, no. 7, pp. 703-706, July 1994.
    • (1994) IEEE Trans. Biomed. Eng , vol.41 , Issue.7 , pp. 703-706
    • Nikolic, Z.M.1
  • 6
    • 0034658085 scopus 로고    scopus 로고
    • A digital averaging method for removal of stimulus artifacts in neurophysiologic experiments
    • T. Wichmann, "A digital averaging method for removal of stimulus artifacts in neurophysiologic experiments," J. Neurosci. Meth., vol. 98, pp. 57-62, 2000.
    • (2000) J. Neurosci. Meth , vol.98 , pp. 57-62
    • Wichmann, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.