메뉴 건너뛰기




Volumn , Issue , 2007, Pages 3926-3929

In vivo cerebral artery microangiography in rat and mouse using synchrotron radiation imaging system

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD VESSELS; IMAGING SYSTEMS; REAL TIME SYSTEMS; SYNCHROTRON RADIATION;

EID: 57649224711     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4353192     Document Type: Conference Paper
Times cited : (14)

References (16)
  • 5
    • 0030951368 scopus 로고    scopus 로고
    • Dynamic Intravenous Coronary Arteriography Using Synchrotron Radiation and Its Application to the Measurement of Coronary Blood Flow
    • S. Ohtsuka, Y. Sugishita, T. Takeda, Y. Itai, K. Hyodo, and M. Ando, "Dynamic Intravenous Coronary Arteriography Using Synchrotron Radiation and Its Application to the Measurement of Coronary Blood Flow," Jpn. Circ. J., vol. 61(5), pp. 432-440, 1997.
    • (1997) Jpn. Circ. J , vol.61 , Issue.5 , pp. 432-440
    • Ohtsuka, S.1    Sugishita, Y.2    Takeda, T.3    Itai, Y.4    Hyodo, K.5    Ando, M.6
  • 8
    • 0032725958 scopus 로고    scopus 로고
    • Digitized Cerebral Synchrotron Radiation Angiography: Quantitative Evaluation of the Canine Circle of Willis and its Large and Small Branches
    • E. Tanaka, A. Tanaka, T. Sekka, Y. Shinozaki, K. Hyodo, K. Umetani, and H. Mori, "Digitized Cerebral Synchrotron Radiation Angiography: Quantitative Evaluation of the Canine Circle of Willis and its Large and Small Branches," Am. J. Neuroradiol., vol. 20, pp. 801-806, 1999.
    • (1999) Am. J. Neuroradiol , vol.20 , pp. 801-806
    • Tanaka, E.1    Tanaka, A.2    Sekka, T.3    Shinozaki, Y.4    Hyodo, K.5    Umetani, K.6    Mori, H.7
  • 11
    • 0022374320 scopus 로고
    • X-ray TV System for Measuring Microcirculation in Small Pulmonary Vessels
    • K. Sada, M. Shirai, and I. Ninomiya, "X-ray TV System for Measuring Microcirculation in Small Pulmonary Vessels," J. Appl. Physiol, vol. 59, pp. 1013-1018, 1985.
    • (1985) J. Appl. Physiol , vol.59 , pp. 1013-1018
    • Sada, K.1    Shirai, M.2    Ninomiya, I.3
  • 12
    • 0032788925 scopus 로고    scopus 로고
    • Segmental Difference in Vasodilatation due to Basal NO Release in In Vivo Cat Pulmonary Vessels
    • M. Shirai, S. Ikeda, K.-Y. Min, A. Shimouchi, T. Kawaguchi, and I. Ninomiya, "Segmental Difference in Vasodilatation due to Basal NO Release in In Vivo Cat Pulmonary Vessels," Respir. Physiol, vol. 116, pp. 159-169, 1999.
    • (1999) Respir. Physiol , vol.116 , pp. 159-169
    • Shirai, M.1    Ikeda, S.2    Min, K.-Y.3    Shimouchi, A.4    Kawaguchi, T.5    Ninomiya, I.6
  • 14
    • 0036858064 scopus 로고    scopus 로고
    • In Vivo Angiographic Detection of Vascular Lesions in Apolipoprotein E-knockout Mice Using a Aynchrotron Radiation Microangiography System
    • T. Yamashita, S. Kawashima, M. Ozaki, M. Namiki, M. Shinohara, N. Inoue, K. Hirata, K. Umetani, and M. Yokoyama, "In Vivo Angiographic Detection of Vascular Lesions in Apolipoprotein E-knockout Mice Using a Aynchrotron Radiation Microangiography System," Circ J., vol. 66, pp. 1057-1059. 2002.
    • (2002) Circ J , vol.66 , pp. 1057-1059
    • Yamashita, T.1    Kawashima, S.2    Ozaki, M.3    Namiki, M.4    Shinohara, M.5    Inoue, N.6    Hirata, K.7    Umetani, K.8    Yokoyama, M.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.