메뉴 건너뛰기




Volumn , Issue , 2007, Pages 5786-5789

Implantable stimulator failures: Causes, outcomes, and solutions

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC CABLES; ELECTRIC CURRENTS; ELECTRIC POWER UTILIZATION; NEUROLOGY; PROSTHETICS;

EID: 57649207953     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4353662     Document Type: Conference Paper
Times cited : (3)

References (23)
  • 1
    • 0035004416 scopus 로고    scopus 로고
    • The application and technology of implantable neuromuscular stimulators: An introduction and overview
    • Jan
    • J. C. Jarvis and S. Salmons, "The application and technology of implantable neuromuscular stimulators: an introduction and overview," Med. Eng. Phys., vol. 23, no. 1, pp. 3-7, Jan. 2001.
    • (2001) Med. Eng. Phys , vol.23 , Issue.1 , pp. 3-7
    • Jarvis, J.C.1    Salmons, S.2
  • 2
    • 21344434555 scopus 로고    scopus 로고
    • Unpredictable implantable cardioverter-defibrillator pulse generator failure due to electrical overstress causing sudden death in a young high-risk patient with hypertrophic cardiomyopathy
    • Jul
    • C. C. Gornick, R. G. Hauser, A. K. Almquist, and B. J. Maron, "Unpredictable implantable cardioverter-defibrillator pulse generator failure due to electrical overstress causing sudden death in a young high-risk patient with hypertrophic cardiomyopathy," Heart Rhythm, vol. 2, no. 7, pp. 681-683, Jul. 2005.
    • (2005) Heart Rhythm , vol.2 , Issue.7 , pp. 681-683
    • Gornick, C.C.1    Hauser, R.G.2    Almquist, A.K.3    Maron, B.J.4
  • 3
    • 0028857312 scopus 로고
    • The first 500 sacral anterior root stimulators: Implant failures and their repair
    • Jan
    • G. S. Brindley, "The first 500 sacral anterior root stimulators: implant failures and their repair," Paraplegia, vol. 33(1), pp. 5-9, Jan. 1995.
    • (1995) Paraplegia , vol.33 , Issue.1 , pp. 5-9
    • Brindley, G.S.1
  • 4
    • 0035005285 scopus 로고    scopus 로고
    • Implanted stimulators for restoration of function in spinal cord injury
    • Jan
    • N. Bhadra, K. L. Kilgore, and P. H. Peckham, "Implanted stimulators for restoration of function in spinal cord injury," Med. Eng. Phys., vol. 23, no. 1, pp. 19-28, Jan. 2001.
    • (2001) Med. Eng. Phys , vol.23 , Issue.1 , pp. 19-28
    • Bhadra, N.1    Kilgore, K.L.2    Peckham, P.H.3
  • 5
    • 0015827822 scopus 로고
    • Capacitor electrode stimulators nerve or muscle without oxidation-reduction reactions
    • Jul
    • D. L. Guyton and F. T. Hambrecht, "Capacitor electrode stimulators nerve or muscle without oxidation-reduction reactions," Sci., vol. 181, pp. 74-76, Jul. 1973.
    • (1973) Sci , vol.181 , pp. 74-76
    • Guyton, D.L.1    Hambrecht, F.T.2
  • 6
    • 84992275000 scopus 로고    scopus 로고
    • BION™ implants for therapeutic and functional electrical stimulation
    • J.K.Chapin, K.A.Moxon, and G.Gaal, Eds. Florida: CRC Press
    • G. E. Loeb and J. R. R. Richmond, "BION™ implants for therapeutic and functional electrical stimulation," in Neural prostheses for restoration of sensor and motor function. J.K.Chapin, K.A.Moxon, and G.Gaal, Eds. Florida: CRC Press, 2000.
    • (2000) Neural prostheses for restoration of sensor and motor function
    • Loeb, G.E.1    Richmond, J.R.R.2
  • 7
    • 0035023266 scopus 로고    scopus 로고
    • Basic design and construction of the Vienna FES implants: Existing solutions and prospects for new generations of implants
    • Jan
    • W. Mayr, M. Bijak, D. Rafolt, S. Sauermann, E. Unger, and H. Lanmuller, "Basic design and construction of the Vienna FES implants: existing solutions and prospects for new generations of implants," Med. Eng. Phys., vol. 23, no. 1, pp. 53-60, Jan. 2001.
    • (2001) Med. Eng. Phys , vol.23 , Issue.1 , pp. 53-60
    • Mayr, W.1    Bijak, M.2    Rafolt, D.3    Sauermann, S.4    Unger, E.5    Lanmuller, H.6
  • 8
    • 0031239099 scopus 로고    scopus 로고
    • Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs
    • T. Cameron, G. E. Loeb, R. A. Peck, J. H. Schulman, P. Strojnik, and P. R. Troyk, "Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs," IEEE Trans. Biomed. Eng., vol. 44, no. 9, pp. 781-790, 1997.
    • (1997) IEEE Trans. Biomed. Eng , vol.44 , Issue.9 , pp. 781-790
    • Cameron, T.1    Loeb, G.E.2    Peck, R.A.3    Schulman, J.H.4    Strojnik, P.5    Troyk, P.R.6
  • 9
    • 0032146996 scopus 로고    scopus 로고
    • Long-term biocompatibility of a miniature stimulator implanted in feline hind limb muscles
    • T. Cameron, T. L. Liinamaa, G. E. Loeb, and F. J. R. Richmond, "Long-term biocompatibility of a miniature stimulator implanted in feline hind limb muscles," IEEE Trans. Biomed. Eng., vol. 45, no. 8, pp. 1024-1035, 1998.
    • (1998) IEEE Trans. Biomed. Eng , vol.45 , Issue.8 , pp. 1024-1035
    • Cameron, T.1    Liinamaa, T.L.2    Loeb, G.E.3    Richmond, F.J.R.4
  • 10
    • 0035369453 scopus 로고    scopus 로고
    • A high-sensitivity polyimide capacitive relative humidity sensor for monitoring anodically bonded hermetic micropackages
    • M. Dokmeci and K. Najafi, "A high-sensitivity polyimide capacitive relative humidity sensor for monitoring anodically bonded hermetic micropackages," J. Microelectromech. Syst., vol. 10, no. 2, pp. 197-204, 2001.
    • (2001) J. Microelectromech. Syst , vol.10 , Issue.2 , pp. 197-204
    • Dokmeci, M.1    Najafi, K.2
  • 11
    • 0024176925 scopus 로고
    • Design and reliability considerations in implants
    • IEEE Engineering in Medicine and Biology Society, pp
    • M. Schaldach, "Design and reliability considerations in implants," in Proc. Annu. Int. Conf. IEEE Engineering in Medicine and Biology Society, pp. 1235-1238, 1988.
    • (1988) Proc. Annu. Int. Conf , pp. 1235-1238
    • Schaldach, M.1
  • 12
    • 0023635662 scopus 로고
    • Present state and future trends in electrical heart stimulation
    • M. Schaldach, "Present state and future trends in electrical heart stimulation," Med. Prog. Technol., vol. 13[2], pp. 85-102, 1987.
    • (1987) Med. Prog. Technol , vol.13 , Issue.2 , pp. 85-102
    • Schaldach, M.1
  • 13
    • 0028746505 scopus 로고
    • Generation of balanced bipolar stimuli based on current sources without coupling capacitor
    • IEEE Engineering in Medicine and Biology Society, pp
    • R. Amand, M. Sawan, and Y. Savaria, "Generation of balanced bipolar stimuli based on current sources without coupling capacitor," in Proc. 16th Ann. Int. Conf. IEEE Engineering in Medicine and Biology Society, pp. 992-993, 1994.
    • (1994) Proc. 16th Ann. Int. Conf , pp. 992-993
    • Amand, R.1    Sawan, M.2    Savaria, Y.3
  • 16
    • 0025940298 scopus 로고
    • Cochlear pathology following chronic electrical stimulation using non charge balanced stimuli
    • Ill, pp
    • R. K. Shepherd, J. Matsushima, R. E. Millard, and G. M. Clark, "Cochlear pathology following chronic electrical stimulation using non charge balanced stimuli," Acta Otolaryngol, vol. Ill, pp. 848-860, 1991.
    • (1991) Acta Otolaryngol, vol , pp. 848-860
    • Shepherd, R.K.1    Matsushima, J.2    Millard, R.E.3    Clark, G.M.4
  • 17
    • 0034995243 scopus 로고    scopus 로고
    • High-voltage stress test paradigms of analog CMOS ICs for gate-oxide reliability enhancement
    • M. A. Khalil and C. L. Wey, "High-voltage stress test paradigms of analog CMOS ICs for gate-oxide reliability enhancement," in Proc. 19th IEEE VLSI Test Symp., pp. 333-338, 2001.
    • (2001) Proc. 19th IEEE VLSI Test Symp , pp. 333-338
    • Khalil, M.A.1    Wey, C.L.2
  • 18
    • 0032954843 scopus 로고    scopus 로고
    • C. Q. Huang, R. K. Shepherd, P. M. Center, P. M. Seligman, and B. Tabor, Electrical stimulation of the auditory nerve: direct current measurement in vivo, IEEE Trans. Biomed. Eng., 46, no. 4, pp. 461469, 1999.
    • C. Q. Huang, R. K. Shepherd, P. M. Center, P. M. Seligman, and B. Tabor, "Electrical stimulation of the auditory nerve: direct current measurement in vivo," IEEE Trans. Biomed. Eng., vol. 46, no. 4, pp. 461469, 1999.
  • 19
  • 20
    • 0034233564 scopus 로고    scopus 로고
    • Implantable measurement technique dedicated to the monitoring of electrode-nerve contact in bladder stimulator
    • Jun
    • C. Donfack, M. Sawan, and Y. Savaria, "Implantable measurement technique dedicated to the monitoring of electrode-nerve contact in bladder stimulator," J. Med. Biol. Eng. Comput., vol. 2, pp. 465-468, Jun. 2000.
    • (2000) J. Med. Biol. Eng. Comput , vol.2 , pp. 465-468
    • Donfack, C.1    Sawan, M.2    Savaria, Y.3
  • 21
    • 11144310593 scopus 로고    scopus 로고
    • Area saving stimulator cells for multielectrode arrays featuring adaptive waveform generation and monitoring
    • IEEE Engineering in Medicine and Biology Society
    • M. Schwarz and M. Maschmann, "Area saving stimulator cells for multielectrode arrays featuring adaptive waveform generation and monitoring," in Proc. 26th Annu. Int. Conf. IEEE Engineering in Medicine and Biology Society, vol. 2, pp. 4314-4317, 2004.
    • (2004) Proc. 26th Annu. Int. Conf , vol.2 , pp. 4314-4317
    • Schwarz, M.1    Maschmann, M.2
  • 22
    • 0030358445 scopus 로고    scopus 로고
    • Stimulator for real time control of paralyzed muscles during functional electrical stimulation
    • H. Dou, A. Asres, Z. Zhou, and S. Zhu, "Stimulator for real time control of paralyzed muscles during functional electrical stimulation," in Proc. 3rd IEEE Int. Conf. Electronics, Circuits, and Systems, vol. 2, pp. 1096-1099, 1996.
    • (1996) Proc. 3rd IEEE Int. Conf. Electronics, Circuits, and Systems , vol.2 , pp. 1096-1099
    • Dou, H.1    Asres, A.2    Zhou, Z.3    Zhu, S.4
  • 23
    • 0032764350 scopus 로고    scopus 로고
    • A high voltage, constant current stimulator for electrocutaneous stimulation through small electrodes
    • C. J. Poletto and C. L. Van Doren, "A high voltage, constant current stimulator for electrocutaneous stimulation through small electrodes," IEEE Trans. Biomed. Eng., vol. 46, no. 8, pp. 929-936, 1999.
    • (1999) IEEE Trans. Biomed. Eng , vol.46 , Issue.8 , pp. 929-936
    • Poletto, C.J.1    Van Doren, C.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.