메뉴 건너뛰기




Volumn , Issue , 2007, Pages 370-373

Adaptive hydrostatic blood pressure calibration: Development of a wearable, autonomous pulse wave velocity blood pressure monitor

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION; IDENTIFICATION (CONTROL SYSTEMS); SENSORS; WEARABLE COMPUTERS;

EID: 57649198689     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4352301     Document Type: Conference Paper
Times cited : (41)

References (13)
  • 1
    • 22844448780 scopus 로고    scopus 로고
    • Hypertension in adults across the age spectrum: Current outcomes and control in the community
    • Jul 27
    • Lloyd-Jones DM, Evans JC, Levy D. Hypertension in adults across the age spectrum: current outcomes and control in the community. Jama. Jul 27 2005;294(4):466-472.
    • (2005) Jama , vol.294 , Issue.4 , pp. 466-472
    • Lloyd-Jones, D.M.1    Evans, J.C.2    Levy, D.3
  • 2
    • 33645830718 scopus 로고    scopus 로고
    • Hypertension: Trends in prevalence, incidence, and control
    • Hajjar I, Kotchen JM, Kotchen TA. Hypertension: trends in prevalence, incidence, and control. Annu Rev Public Health. 2006;27:465-490.
    • (2006) Annu Rev Public Health , vol.27 , pp. 465-490
    • Hajjar, I.1    Kotchen, J.M.2    Kotchen, T.A.3
  • 3
    • 0035527578 scopus 로고    scopus 로고
    • Home blood pressure monitoring. Current knowledge and directions for future research
    • Reims H, Fossum E, Kjeldsen SE, Julius S. Home blood pressure monitoring. Current knowledge and directions for future research. Blood Press. 2001;10(5-6):271-287.
    • (2001) Blood Press , vol.10 , Issue.5-6 , pp. 271-287
    • Reims, H.1    Fossum, E.2    Kjeldsen, S.E.3    Julius, S.4
  • 5
    • 0030837142 scopus 로고    scopus 로고
    • Epidemiology of ambulatory blood pressure monitoring
    • Apr
    • Staessen JA. Epidemiology of ambulatory blood pressure monitoring. Blood Press Monit. Apr 1997;2(2):61-64.
    • (1997) Blood Press Monit , vol.2 , Issue.2 , pp. 61-64
    • Staessen, J.A.1
  • 6
    • 33744501815 scopus 로고    scopus 로고
    • Ambulatory blood-pressure monitoring
    • Jun 1
    • Pickering TG, Shimbo D, Haas D. Ambulatory blood-pressure monitoring. N Engl J Med. Jun 1 2006;354(22):2368-2374.
    • (2006) N Engl J Med , vol.354 , Issue.22 , pp. 2368-2374
    • Pickering, T.G.1    Shimbo, D.2    Haas, D.3
  • 10
    • 0016643045 scopus 로고
    • Adaptive Noise Cancelling: Principles and Applications
    • Dec
    • Widrow B, et al. Adaptive Noise Cancelling: Principles and Applications. Proceedings of the IEEE. Dec 1975; Vol. 63, No.12, pg 1692-1716.
    • (1975) Proceedings of the IEEE , vol.63 , Issue.12 , pp. 1692-1716
    • Widrow, B.1
  • 12
    • 0034281859 scopus 로고    scopus 로고
    • Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration
    • Sept
    • W. Chen, T. Kobayashi, S. Ichikawa, Y. Takeuchi, T. Togawa, "Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration," Med. Boil. Eng. Comp., vol. 38(5), pp 567-574, Sept. 2000.
    • (2000) Med. Boil. Eng. Comp , vol.38 , Issue.5 , pp. 567-574
    • Chen, W.1    Kobayashi, T.2    Ichikawa, S.3    Takeuchi, Y.4    Togawa, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.