메뉴 건너뛰기




Volumn , Issue , 2007, Pages 2350-2353

A novel photodiode for reflectance pulse oximetry in low-power applications

Author keywords

[No Author keywords available]

Indexed keywords

OXIMETERS; PHOTODIODES; SENSORS; WAVELENGTH; WEARABLE COMPUTERS;

EID: 57649198277     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4352798     Document Type: Conference Paper
Times cited : (9)

References (13)
  • 3
    • 0024094414 scopus 로고
    • Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography
    • Y. Mendelson, "Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography", IEEE Transactions on Biomedical Engineering, vol. 35, nr. 10, pp 798-805, 1988
    • (1988) IEEE Transactions on Biomedical Engineering , vol.35 , Issue.NR. 10 , pp. 798-805
    • Mendelson, Y.1
  • 4
    • 0026514983 scopus 로고
    • Reflectance Pulse oximetry in fetal lambs
    • A.C. Dassel, "Reflectance Pulse oximetry in fetal lambs", Pediatr. Res., vol. 31, nr. 6 pp 266-269, 1992
    • (1992) Pediatr. Res , vol.31 , Issue.NR. 6 , pp. 266-269
    • Dassel, A.C.1
  • 5
    • 0024060774 scopus 로고
    • Design and evaluation of a new reflectance pulse oximeter sensor
    • Y. Mendelson, "Design and evaluation of a new reflectance pulse oximeter sensor", Medical Instrumentation, vol. 22, nr. 4, pp 167-173, 1988
    • (1988) Medical Instrumentation , vol.22 , Issue.NR. 4 , pp. 167-173
    • Mendelson, Y.1
  • 6
    • 1542360609 scopus 로고    scopus 로고
    • Measurement site and photodetector size considerations in optimizing power consuption of a wearable reflectance pulse oximeter
    • Y. Mendelson, "Measurement site and photodetector size considerations in optimizing power consuption of a wearable reflectance pulse oximeter", Proc. 25th Annual IEEE EMBS conf., pp 3016-3019, 2003
    • (2003) Proc. 25th Annual IEEE EMBS conf , pp. 3016-3019
    • Mendelson, Y.1
  • 7
    • 0031288881 scopus 로고    scopus 로고
    • A new hybrid reflectance optical pulse oximetry sensor for lower oxygen saturation measurements and for broader clinical applications
    • S. Takatani, "A new hybrid reflectance optical pulse oximetry sensor for lower oxygen saturation measurements and for broader clinical applications", Proc. SPIE, nr. 2976, pp 78-87, 1997
    • (1997) Proc. SPIE , Issue.NR. 2976 , pp. 78-87
    • Takatani, S.1
  • 8
    • 0032278601 scopus 로고    scopus 로고
    • A novel hybrid reflectance pulse oximeter sensor with improved linearity and general applicability to various portions of the body
    • S. Takatani, "A novel hybrid reflectance pulse oximeter sensor with improved linearity and general applicability to various portions of the body", Proc. 20th Annual IEEE EMBS conf., vol. 20, nr. 4, pp 1858-1861, 1998
    • (1998) Proc. 20th Annual IEEE EMBS conf , vol.20 , Issue.NR. 4 , pp. 1858-1861
    • Takatani, S.1
  • 9
    • 0032278801 scopus 로고    scopus 로고
    • The Ring Sensor: A New Ambulatory Wearable Sensor for Twenty-Four Hour Patient Monitoring
    • H. Asada, "The Ring Sensor: a New Ambulatory Wearable Sensor for Twenty-Four Hour Patient Monitoring", Proc. 20th Annual IEEE EMBS conf., vol. 4, pp 1906-1909, 1998
    • (1998) Proc. 20th Annual IEEE EMBS conf , vol.4 , pp. 1906-1909
    • Asada, H.1
  • 10
    • 0034968268 scopus 로고    scopus 로고
    • Artifact-resistant power-efficient design of finger-ring Plethysmographic sensors
    • H. Asada, "Artifact-resistant power-efficient design of finger-ring Plethysmographic sensors", IEEE Transactions on Biomedical Engineering, vol. 48, nr. 7, pp 795-805, 2001
    • (2001) IEEE Transactions on Biomedical Engineering , vol.48 , Issue.NR. 7 , pp. 795-805
    • Asada, H.1
  • 11
    • 2642549173 scopus 로고    scopus 로고
    • Minimazation of LED power consumption in the design of a wearable pulse oximeter
    • Y Mendelson, "Minimazation of LED power consumption in the design of a wearable pulse oximeter", Proc. IASTED Conf. on Biomedical Engineering, pp 249-254, 2003
    • (2003) Proc. IASTED Conf. on Biomedical Engineering , pp. 249-254
    • Mendelson, Y.1
  • 12
    • 33749353588 scopus 로고    scopus 로고
    • A wrist-worn integrated health monitoring instrument with a tele-reporting device for telemedicine and telecare
    • T. Yoo, "A wrist-worn integrated health monitoring instrument with a tele-reporting device for telemedicine and telecare", IEEE Transactions on Instrumentation and Measurement, vol. 55, nr. 5, pp 1655-1661, 2006
    • (2006) IEEE Transactions on Instrumentation and Measurement , vol.55 , Issue.NR. 5 , pp. 1655-1661
    • Yoo, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.