메뉴 건너뛰기




Volumn , Issue , 2007, Pages 483-486

Wearable accelerometer system for measuring the temporal parameters of gait

Author keywords

[No Author keywords available]

Indexed keywords

ACCELEROMETERS; GAIT ANALYSIS; MEASUREMENT THEORY; PARAMETER ESTIMATION;

EID: 57649193395     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4352328     Document Type: Conference Paper
Times cited : (70)

References (13)
  • 1
    • 28244437279 scopus 로고    scopus 로고
    • Accelerometers in rehabilitation medicine for older adults
    • K. M. Culhane, M. O'Connor, D. Lyons, and G. M. Lyons, "Accelerometers in rehabilitation medicine for older adults," Age Ageing, vol. 34, pp. 556-60, 2005.
    • (2005) Age Ageing , vol.34 , pp. 556-560
    • Culhane, K.M.1    O'Connor, M.2    Lyons, D.3    Lyons, G.M.4
  • 3
    • 33646531214 scopus 로고    scopus 로고
    • Reliability and validity of bilateral thigh and foot accelerometry measures of walking in healthy and hemiparetic subjects
    • K. Saremi, J. Marehbian, X. Yan, J. P. Regnaux, R. Elashoff, B. Bussel, and B. H. Dobkin, "Reliability and validity of bilateral thigh and foot accelerometry measures of walking in healthy and hemiparetic subjects," Neurorehabil Neural Repair, vol. 20, pp. 297-305, 2006.
    • (2006) Neurorehabil Neural Repair , vol.20 , pp. 297-305
    • Saremi, K.1    Marehbian, J.2    Yan, X.3    Regnaux, J.P.4    Elashoff, R.5    Bussel, B.6    Dobkin, B.H.7
  • 4
    • 0031127592 scopus 로고    scopus 로고
    • A Holter-type, microprocessor-based, rehabilitation instrument for acquisition and storage of plantar pressure data
    • Z. O. Abu-Faraj, G. F. Harris, J. H. Abler, and J. J. Wertsch, "A Holter-type, microprocessor-based, rehabilitation instrument for acquisition and storage of plantar pressure data," J Rehabil Res Dev, vol. 34, pp. 187-94, 1997.
    • (1997) J Rehabil Res Dev , vol.34 , pp. 187-194
    • Abu-Faraj, Z.O.1    Harris, G.F.2    Abler, J.H.3    Wertsch, J.J.4
  • 6
    • 19044387782 scopus 로고    scopus 로고
    • Fractal dynamics of body motion in post-stroke hemiplegic patients during walking
    • M. Akay, M. Sekine, T. Tamura, Y. Higashi, and T. Fujimoto, "Fractal dynamics of body motion in post-stroke hemiplegic patients during walking," J Neural Eng, vol. 1, pp. 111-6, 2004.
    • (2004) J Neural Eng , vol.1 , pp. 111-116
    • Akay, M.1    Sekine, M.2    Tamura, T.3    Higashi, Y.4    Fujimoto, T.5
  • 7
    • 0026069259 scopus 로고
    • Recording accelerations in body movements
    • A. L. Evans, G. Duncan, and W. Gilchrist, "Recording accelerations in body movements," Med Biol Eng Comput, vol. 29, pp. 102-4, 1991.
    • (1991) Med Biol Eng Comput , vol.29 , pp. 102-104
    • Evans, A.L.1    Duncan, G.2    Gilchrist, W.3
  • 8
    • 0033373252 scopus 로고    scopus 로고
    • Temporal feature estimation during walking using miniature accelerometers: An analysis of gait improvement after hip arthroplasty
    • K. Aminian, K. Rezakhanlou, E. De Andres, C. Fritsch, P. F. Leyvraz, and P. Robert, "Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty," Med Biol Eng Comput, vol. 37, pp. 686-91, 1999.
    • (1999) Med Biol Eng Comput , vol.37 , pp. 686-691
    • Aminian, K.1    Rezakhanlou, K.2    De Andres, E.3    Fritsch, C.4    Leyvraz, P.F.5    Robert, P.6
  • 9
    • 0344084396 scopus 로고    scopus 로고
    • Assessment of spatio-temporal gait parameters from trunk accelerations during human walking
    • W. Zijlstra and A. L. Hof, "Assessment of spatio-temporal gait parameters from trunk accelerations during human walking," Gait Posture, vol. 18, pp. 1-10, 2003.
    • (2003) Gait Posture , vol.18 , pp. 1-10
    • Zijlstra, W.1    Hof, A.L.2
  • 10
    • 27144460856 scopus 로고    scopus 로고
    • The intra-rater reliability of the balance performance monitor when measuring sitting symmetry and weight-shift activity after stroke in a community setting
    • C. M. Sackley, H. J. Hill, K. Pound, and A. Foxall, "The intra-rater reliability of the balance performance monitor when measuring sitting symmetry and weight-shift activity after stroke in a community setting," Clin Rehabil vol. 19, pp. 746-50, 2005.
    • (2005) Clin Rehabil , vol.19 , pp. 746-750
    • Sackley, C.M.1    Hill, H.J.2    Pound, K.3    Foxall, A.4
  • 11
    • 0029256487 scopus 로고
    • Footswitch system for measurement of the temporal parameters of gait
    • J. M. Hausdorff, Z. Ladin, and J. Y. Wei, "Footswitch system for measurement of the temporal parameters of gait," J Biomech, vol. 28, pp. 347-51, 1995.
    • (1995) J Biomech , vol.28 , pp. 347-351
    • Hausdorff, J.M.1    Ladin, Z.2    Wei, J.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.