In vivo rat knee cartilage volume measurement using quantitative high resolution MRI (7 T): Feasibility and reproducibility

Author keywords

Cartilage; In vivo; Quantitative MRI; Rat; Reproducibility; Volume

Indexed keywords

IMAGE SEGMENTATION; RATING; RATS;

EID: 57649186728     PISSN: 09592989     EISSN: None     Source Type: Journal    
DOI: 10.3233/BME-2008-0533     Document Type: Conference Paper
Times cited : (11)

References (13)
  • 1
    • 28744451238 scopus 로고    scopus 로고
    • High-resolution MRI techniques for studies in small-animal models
    • O. Beuf, High-resolution MRI techniques for studies in small-animal models, Methods Mol. Med. 101 (2004), 219-229.
    • (2004) Methods Mol. Med , vol.101 , pp. 219-229
    • Beuf, O.1
  • 2
    • 44649122165 scopus 로고    scopus 로고
    • a reproducibility study in a meniscectomized guinea pig model of osteoarthritis
    • Measurement of knee cartilage thickness using MRI
    • R. Bolbos, H. Benoit-Cattin, J.B. Langlois, A. Chomel, E. Chereul, C. Odet, M. Janier, P. Pastoureau and O. Beuf, Measurement of knee cartilage thickness using MRI: a reproducibility study in a meniscectomized guinea pig model of osteoarthritis, NMR Biomed. 21 (2008), 366-375.
    • (2008) NMR Biomed , vol.21 , pp. 366-375
    • Bolbos, R.1    Benoit-Cattin, H.2    Langlois, J.B.3    Chomel, A.4    Chereul, E.5    Odet, C.6    Janier, M.7    Pastoureau, P.8    Beuf, O.9
  • 4
    • 33846822071 scopus 로고    scopus 로고
    • The magic angle effect: A source of artifact, determinant of image contrast, and technique for imaging
    • M. Bydder, A. Rahal, G.D. Fullerton and G.M. Bydder, The magic angle effect: a source of artifact, determinant of image contrast, and technique for imaging, J. Magn. Reson. Imaging 25 (2007), 290-300.
    • (2007) J. Magn. Reson. Imaging , vol.25 , pp. 290-300
    • Bydder, M.1    Rahal, A.2    Fullerton, G.D.3    Bydder, G.M.4
  • 5
    • 33745161076 scopus 로고    scopus 로고
    • morphological assessment
    • Magnetic resonance imaging (MRI) of articular cartilage in knee osteoarthritis OA
    • F. Eckstein, F. Cicuttini, J.P. Raynauld, J.C. Waterton and C. Peterfy, Magnetic resonance imaging (MRI) of articular cartilage in knee osteoarthritis (OA): morphological assessment, Osteoarthritis Cartilage 14(Suppl A) (2006), A46-A75.
    • (2006) Osteoarthritis Cartilage , vol.14 , Issue.SUPPL. A
    • Eckstein, F.1    Cicuttini, F.2    Raynauld, J.P.3    Waterton, J.C.4    Peterfy, C.5
  • 6
    • 0346025552 scopus 로고    scopus 로고
    • In-vivo high resolution three-dimensional MRI studies of rat joints at 7 T
    • P. Faure, B.T. Doan and J.C. Beloeil, In-vivo high resolution three-dimensional MRI studies of rat joints at 7 T, NMR Biomed. 16 (2003), 484-493.
    • (2003) NMR Biomed , vol.16 , pp. 484-493
    • Faure, P.1    Doan, B.T.2    Beloeil, J.C.3
  • 7
    • 0345168011 scopus 로고    scopus 로고
    • Femoro-tibial cartilage metrics from coronal MR image data: Technique, test-retest reproducibility, and findings in osteoarthritis
    • C. Glaser, R. Burgkart, A. Kutschera, K.H. Englmeier, M. Reiser and F. Eckstein, Femoro-tibial cartilage metrics from coronal MR image data: Technique, test-retest reproducibility, and findings in osteoarthritis, Magn. Reson. Med. 50 (2003), 1229-1236.
    • (2003) Magn. Reson. Med , vol.50 , pp. 1229-1236
    • Glaser, C.1    Burgkart, R.2    Kutschera, A.3    Englmeier, K.H.4    Reiser, M.5    Eckstein, F.6
  • 8
    • 0029112340 scopus 로고
    • Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniques
    • C.C. Gluer, G. Blake, Y. Lu, B.A. Blunt, M. Jergas and H.K. Genant, Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques, Osteoporos. Int. 5 (1995), 262-270.
    • (1995) Osteoporos. Int , vol.5 , pp. 262-270
    • Gluer, C.C.1    Blake, G.2    Lu, Y.3    Blunt, B.A.4    Jergas, M.5    Genant, H.K.6
  • 11
    • 3342959136 scopus 로고    scopus 로고
    • High resolution MRI relaxation measurements of water in the articular cartilage of the meniscectomized rat knee at 4.7 T
    • Y. Spandonis, F.P. Heese and L.D. Hall, High resolution MRI relaxation measurements of water in the articular cartilage of the meniscectomized rat knee at 4.7 T, Magn. Reson. Imaging 22 (2004), 943-951.
    • (2004) Magn. Reson. Imaging , vol.22 , pp. 943-951
    • Spandonis, Y.1    Heese, F.P.2    Hall, L.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.