메뉴 건너뛰기




Volumn , Issue , 2007, Pages 6055-6058

A compact nanopower low output impedance CMOS operational amplifier for wireless intraocular pressure recordings

Author keywords

[No Author keywords available]

Indexed keywords

CMOS INTEGRATED CIRCUITS; ELECTRIC POWER UTILIZATION; OPERATIONAL AMPLIFIERS; PATIENT TREATMENT;

EID: 57649174739     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4353729     Document Type: Conference Paper
Times cited : (9)

References (14)
  • 3
    • 0033985639 scopus 로고    scopus 로고
    • A portable microsystem-based telemetric pressure and temperature measurement unit
    • B. B. Flick and R. Orglmeister, "A portable microsystem-based telemetric pressure and temperature measurement unit," IEEE Trans. on Biomedical Engineering, 47(1), pp. 12-6, 2000.
    • (2000) IEEE Trans. on Biomedical Engineering , vol.47 , Issue.1 , pp. 12-16
    • Flick, B.B.1    Orglmeister, R.2
  • 4
    • 1542346118 scopus 로고    scopus 로고
    • Initial animal studies of a wireless, batteryless, MEMS implant for cardiovascular applications
    • N. Najafi and A. Ludomirsky, "Initial animal studies of a wireless, batteryless, MEMS implant for cardiovascular applications," J. Biomedical Microdevices, 6(1), pp. 61-5, 2004.
    • (2004) J. Biomedical Microdevices , vol.6 , Issue.1 , pp. 61-65
    • Najafi, N.1    Ludomirsky, A.2
  • 5
    • 18744381850 scopus 로고    scopus 로고
    • Modeling and characterization of a valved glaucoma drainage device with implications for enhanced therapeutic efficacy
    • T. Pan, M. S. Stay, V. H. Barocas, J. D. Brown, and B. Ziaie, "Modeling and characterization of a valved glaucoma drainage device with implications for enhanced therapeutic efficacy," IEEE Trans. on Biomedical Engineering, 52(5), pp. 948-51, 2005.
    • (2005) IEEE Trans. on Biomedical Engineering , vol.52 , Issue.5 , pp. 948-951
    • Pan, T.1    Stay, M.S.2    Barocas, V.H.3    Brown, J.D.4    Ziaie, B.5
  • 6
    • 28344454238 scopus 로고    scopus 로고
    • Validity of screening for glaucomatous optic nerve damage using confocal scanning laser ophthalmoscopy (Heidelberg Retina Tomograph II) in high-risk populations: A pilot study
    • P. J. Harasymowycz, D. G. Papamatheakis, A. K. Fansi, J. Gresset, and M. R. Lesk, "Validity of screening for glaucomatous optic nerve damage using confocal scanning laser ophthalmoscopy (Heidelberg Retina Tomograph II) in high-risk populations: a pilot study," Ophthalmology, 112(12), pp. 2164-71, 2005.
    • (2005) Ophthalmology , vol.112 , Issue.12 , pp. 2164-2171
    • Harasymowycz, P.J.1    Papamatheakis, D.G.2    Fansi, A.K.3    Gresset, J.4    Lesk, M.R.5
  • 7
    • 38049069408 scopus 로고    scopus 로고
    • World Health Organization, Geneva, Switzerland, Online, Available
    • (2005). World Health Organization, Geneva, Switzerland, [Online]. Available: http://www.who.org.
  • 8
    • 0037377927 scopus 로고    scopus 로고
    • Twenty-fourhour intraocular pressure pattern associated with early glaucomatous changes
    • J. H. Liu, X. Zhang, D. F. Kripke, and R. N. Weinreb, "Twenty-fourhour intraocular pressure pattern associated with early glaucomatous changes," Investigative Ophthalmology & Visual Science, 44(4), pp. 1586-90, 2003.
    • (2003) Investigative Ophthalmology & Visual Science , vol.44 , Issue.4 , pp. 1586-1590
    • Liu, J.H.1    Zhang, X.2    Kripke, D.F.3    Weinreb, R.N.4
  • 9
    • 0034923628 scopus 로고    scopus 로고
    • Intraocular pressure measurement at the choroid surface: A feasibility study with implications for implantable microsystems
    • R. N. Rizq, W-H Choi, D. Eilers, M. M. Wright, and B. Ziaie, "Intraocular pressure measurement at the choroid surface: a feasibility study with implications for implantable microsystems," British J. Ophthalmology, 85(7), pp. 868-71, 2001.
    • (2001) British J. Ophthalmology , vol.85 , Issue.7 , pp. 868-871
    • Rizq, R.N.1    Choi, W.-H.2    Eilers, D.3    Wright, M.M.4    Ziaie, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.