메뉴 건너뛰기




Volumn , Issue , 2007, Pages 3982-3985

Improvement of hemolysis in a centrifugal blood pump with hydrodynamic bearings and semi-open impeller

Author keywords

[No Author keywords available]

Indexed keywords

FLUID DYNAMICS; HEMODIALYZERS; MAGNETIC FORCE MICROSCOPY; PARTICLE SIZE; SENSORS;

EID: 57649165776     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4353206     Document Type: Conference Paper
Times cited : (7)

References (8)
  • 1
    • 33644873240 scopus 로고    scopus 로고
    • Design Considerations of Volute Geometry of a Centrifugal Blood Pump
    • Chan WK, Wong YW, Hu W. Design Considerations of Volute Geometry of a Centrifugal Blood Pump. Artif Organs 2005; 29: 937-948
    • (2005) Artif Organs , vol.29 , pp. 937-948
    • Chan, W.K.1    Wong, Y.W.2    Hu, W.3
  • 2
    • 10044219918 scopus 로고    scopus 로고
    • Current status of the Gyro Centrifugal Blood Pump-Development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO Project)
    • Nosé Y and Furukawa K. Current status of the Gyro Centrifugal Blood Pump-Development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO Project). Artif Organs 2004; 28:953-958
    • (2004) Artif Organs , vol.28 , pp. 953-958
    • Nosé, Y.1    Furukawa, K.2
  • 4
    • 33646243597 scopus 로고    scopus 로고
    • Third Generation Blood Pumps With Mechanical Non-Contact Magnetic Bearing
    • Hoshi H, Shinshi T, Takatani, Third Generation Blood Pumps With Mechanical Non-Contact Magnetic Bearing, Artif Organs 2006; 30: 324-339.
    • (2006) Artif Organs , vol.30 , pp. 324-339
    • Hoshi, H.1    Shinshi, T.2    Takatani3
  • 6
    • 0036631267 scopus 로고    scopus 로고
    • Magnetically suspended centrifugal blood pump with a self bering motor
    • Amasuzawa T, Omuma H, Kim SJ, Okada Y. Magnetically suspended centrifugal blood pump with a self bering motor. ASAIO J 2002; 48: 437-42
    • (2002) ASAIO J , vol.48 , pp. 437-442
    • Amasuzawa, T.1    Omuma, H.2    Kim, S.J.3    Okada, Y.4
  • 7
    • 0242678387 scopus 로고    scopus 로고
    • Testing of a Centrifugal Blood Pump with a High Efficiency Hybrid Magnetic Bearing
    • Locke DH, Swanson ES, Walton JF, Willis JP, and Heshmat H, Testing of a Centrifugal Blood Pump with a High Efficiency Hybrid Magnetic Bearing. ASAIO Journal 2003; 49: 737-743.
    • (2003) ASAIO Journal , vol.49 , pp. 737-743
    • Locke, D.H.1    Swanson, E.S.2    Walton, J.F.3    Willis, J.P.4    Heshmat, H.5
  • 8
    • 0034823898 scopus 로고    scopus 로고
    • The Heartmate III: Design and in vivo studies of a maglev centrifugal left ventricular assist device
    • Loree HM, Bourque K, Gernes DB, The Heartmate III: design and in vivo studies of a maglev centrifugal left ventricular assist device. Artif Organs 2001; 25: 386-91.
    • (2001) Artif Organs , vol.25 , pp. 386-391
    • Loree, H.M.1    Bourque, K.2    Gernes, D.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.