메뉴 건너뛰기




Volumn , Issue , 2007, Pages 1570-1573

EEG frequency progression during induction of anesthesia: From start of infusion to onset of burst suppression pattern

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; ANESTHESIOLOGY; ESTIMATION;

EID: 57649165666     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4352604     Document Type: Conference Paper
Times cited : (23)

References (10)
  • 1
    • 0033812632 scopus 로고    scopus 로고
    • Monitoring depth of anesthesia: With emphasis on the application of the bispectral index and the middle latency auditory evoked response to the prevention of recall
    • Sep
    • J. C. Drummond, "Monitoring depth of anesthesia: With emphasis on the application of the bispectral index and the middle latency auditory evoked response to the prevention of recall," Anesthesiology, vol. 93, pp. 876-882, Sep. 2000
    • (2000) Anesthesiology , vol.93 , pp. 876-882
    • Drummond, J.C.1
  • 2
    • 0026610664 scopus 로고
    • Induction dose-responses studies with propofol and thiopentone
    • Mar
    • M. Naguib, A. Sari-Kouzel, M. Seraj, M. el-Gammal, and M. Gomma, "Induction dose-responses studies with propofol and thiopentone," Br. J. Anaesth., vol 68, pp. 308-310, Mar. 1992.
    • (1992) Br. J. Anaesth , vol.68 , pp. 308-310
    • Naguib, M.1    Sari-Kouzel, A.2    Seraj, M.3    el-Gammal, M.4    Gomma, M.5
  • 3
    • 0027410352 scopus 로고    scopus 로고
    • Effect site equilibration time is a determinant of induction dose requirements
    • J. R. Jacobs and J. G. Reves, "Effect site equilibration time is a determinant of induction dose requirements," Anest. Analg., vol 76, pp. 1-6.
    • Anest. Analg , vol.76 , pp. 1-6
    • Jacobs, J.R.1    Reves, J.G.2
  • 4
    • 0030021080 scopus 로고    scopus 로고
    • Measuring the performance of anesthetic depth indicators
    • Jan
    • W. D. Smith, R. C. Dutton, and N. T. Smith, "Measuring the performance of anesthetic depth indicators," Anesthesiology, vol. 84, pp. 38-51, Jan. 1996.
    • (1996) Anesthesiology , vol.84 , pp. 38-51
    • Smith, W.D.1    Dutton, R.C.2    Smith, N.T.3
  • 5
    • 0035105170 scopus 로고    scopus 로고
    • Biphasic EEG changes in relation to loss of consciousness during induction with thiopental, propofol, etomidate, midazolam or sevoflurane
    • K. Kuizenga, J. M. Wierda, and C. J Kalkman, "Biphasic EEG changes in relation to loss of consciousness during induction with thiopental, propofol, etomidate, midazolam or sevoflurane," Br. J. Anaesth., vol. 86, pp. 354-360.
    • Br. J. Anaesth , vol.86 , pp. 354-360
    • Kuizenga, K.1    Wierda, J.M.2    Kalkman, C.J.3
  • 6
    • 1842714959 scopus 로고    scopus 로고
    • The Narcotrend Index: Classification algorithm, correlation with propofol effect-site concentrations, and comparison with spectral parameters
    • A. Schultz, U. Grouven, F. A. Beger, and B. Schultz, "The Narcotrend Index: classification algorithm, correlation with propofol effect-site concentrations, and comparison with spectral parameters," Biomed. Technik, vol. 49, pp. 38-42.
    • Biomed. Technik , vol.49 , pp. 38-42
    • Schultz, A.1    Grouven, U.2    Beger, F.A.3    Schultz, B.4
  • 7
    • 24344486475 scopus 로고    scopus 로고
    • Relation of EEG spectrum progression to loss of responsiveness during induction of anesthesia with propofol
    • M. Koskinen, S. Mustola, and T. Seppänen, "Relation of EEG spectrum progression to loss of responsiveness during induction of anesthesia with propofol," Clin. Neurophysiol., vol. 116, pp. 2069-2076, 2005.
    • (2005) Clin. Neurophysiol , vol.116 , pp. 2069-2076
    • Koskinen, M.1    Mustola, S.2    Seppänen, T.3
  • 8
    • 33749520636 scopus 로고    scopus 로고
    • Forecasting the unresponsiveness to verbal command on the basis of EEG frequency progression during anesthetic induction with propofol
    • Oct
    • M. Koskinen, S. Mustola, and T. Seppänen, "Forecasting the unresponsiveness to verbal command on the basis of EEG frequency progression during anesthetic induction with propofol," IEEE Trans. Biomed. Eng., vol. 53, no. 10, pp. 2008-2014, Oct. 2006.
    • (2006) IEEE Trans. Biomed. Eng , vol.53 , Issue.10 , pp. 2008-2014
    • Koskinen, M.1    Mustola, S.2    Seppänen, T.3
  • 9
    • 0025677111 scopus 로고
    • FIR-median hybrid filters with excellent transient response in noisy conditions
    • Dec
    • R. Wichman, J. T. Astola, P. J. Heinonen, and Y. A. Neuvo, "FIR-median hybrid filters with excellent transient response in noisy conditions," IEEE Trans. Acoust. Speech Signal Process., vol. 38, no. 12, pp. 2018-2117, Dec. 1990.
    • (1990) IEEE Trans. Acoust. Speech Signal Process , vol.38 , Issue.12 , pp. 2018-2117
    • Wichman, R.1    Astola, J.T.2    Heinonen, P.J.3    Neuvo, Y.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.