메뉴 건너뛰기




Volumn , Issue , 2007, Pages 2775-2778

Collection and exploratory analysis of attitude sensor data in an epilepsy monitoring unit

Author keywords

Accelerometer; Attitude sensors; Epilepsy; Feature extraction; Magnetometer; Monitoring; Movement; Principal component analysis; Seizures

Indexed keywords

ACCELEROMETERS; FEATURE EXTRACTION; MAGNETOMETERS; MEDICAL PROBLEMS; PRINCIPAL COMPONENT ANALYSIS;

EID: 57649146374     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4352904     Document Type: Conference Paper
Times cited : (18)

References (12)
  • 2
    • 20444495737 scopus 로고    scopus 로고
    • Quantifying motion in video recordings of neonatal seizures by robust motion trackers based on block motion models
    • N. B. Karayiannis et al., Quantifying motion in video recordings of neonatal seizures by robust motion trackers based on block motion models, IEEE Trans. on Biomed. Eng., 52(6): 1065-1077, 2005
    • (2005) IEEE Trans. on Biomed. Eng , vol.52 , Issue.6 , pp. 1065-1077
    • Karayiannis, N.B.1
  • 3
    • 33744496025 scopus 로고    scopus 로고
    • Automated detection of videotaped neonatal seizures of epileptic origin
    • N. B. Karayiannis et al., Automated detection of videotaped neonatal seizures of epileptic origin, Epilepsia, 47(6): 966-980, 2006
    • (2006) Epilepsia , vol.47 , Issue.6 , pp. 966-980
    • Karayiannis, N.B.1
  • 4
    • 0036095842 scopus 로고    scopus 로고
    • Movement quantification in epileptic seizures: A new approach to video-EEG analysis
    • Z. Li, A. M. da Silva and J. P. da Silva Cunha, Movement quantification in epileptic seizures: a new approach to video-EEG analysis, IEEE Trans. on Biomed. Eng., 49(6): 565-573, 2002
    • (2002) IEEE Trans. on Biomed. Eng , vol.49 , Issue.6 , pp. 565-573
    • Li, Z.1    da Silva, A.M.2    da Silva Cunha, J.P.3
  • 5
    • 0017905102 scopus 로고
    • Triaxial accelerometry: A method for quantifying tremor and ataxia
    • J. D. Frost, Triaxial accelerometry: a method for quantifying tremor and ataxia, IEEE Trans. on Biomed. Eng., vol. 25, p. 17-27, 1978
    • (1978) IEEE Trans. on Biomed. Eng , vol.25 , pp. 17-27
    • Frost, J.D.1
  • 7
    • 22144470484 scopus 로고    scopus 로고
    • The potential value of three-dimensional accelerometry for detection of motor seizures in severe epilepsy
    • T. M. E. Nijsen et al., The potential value of three-dimensional accelerometry for detection of motor seizures in severe epilepsy, Epilepsy and Behavior, 7:74-84, 2005
    • (2005) Epilepsy and Behavior , vol.7 , pp. 74-84
    • Nijsen, T.M.E.1
  • 9
    • 34250788516 scopus 로고    scopus 로고
    • A magnetometer-based approach for studying human movements
    • accepted for publication
    • S. Bonnet and R. Héliot, A magnetometer-based approach for studying human movements, IEEE Trans. on Biomed. Eng., accepted for publication, 2007
    • (2007) IEEE Trans. on Biomed. Eng
    • Bonnet, S.1    Héliot, R.2
  • 11
    • 0031687333 scopus 로고    scopus 로고
    • Semiological Seizure Classification
    • H. Lüders et al., Semiological Seizure Classification, Epilepsia, 39(9): 1006-1013, 1998
    • (1998) Epilepsia , vol.39 , Issue.9 , pp. 1006-1013
    • Lüders, H.1
  • 12
    • 38049021353 scopus 로고    scopus 로고
    • Matlab®, Apple Hill Drive Natick, MA
    • Matlab®, The MathWorks Inc., 3 Apple Hill Drive Natick, MA, http ://www.mathworks.com/
    • The MathWorks Inc , vol.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.