Volumn 16, Issue 1, 2009, Pages 48-51

Radiology of Urolithiasis: Implications of Radiation Exposure and New Imaging Modalities

Author keywords

Computed tomography; Multidetector computed tomography; Radiation dose; Urinary tract

Indexed keywords

ARTICLE; CALCIUM OXALATE STONE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; DIAGNOSTIC ACCURACY; DIAGNOSTIC APPROACH ROUTE; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; HUMAN; IMAGE QUALITY; INTRAVENOUS UROGRAPHY; MULTIDETECTOR COMPUTED TOMOGRAPHY; NON INVASIVE PROCEDURE; PRIORITY JOURNAL; RADIATION DETECTION; RADIATION DOSE; RADIATION EXPOSURE; URIC ACID STONE; UROLITHIASIS;

EID: 57449099844     PISSN: 15485595     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.ackd.2008.10.006     Document Type: Article
Times cited : (11)

References (15)
  • 1
    • 44349176789 scopus 로고    scopus 로고
    • Radiation safety in the era of helical CT: A patient-based protection program currently in place in two community hospitals in New Hampshire
    • Birnbaum S. Radiation safety in the era of helical CT: A patient-based protection program currently in place in two community hospitals in New Hampshire. J Am Coll Radiol 5 (2008) 714-718
    • (2008) J Am Coll Radiol , vol.5 , pp. 714-718
    • Birnbaum, S.1
  • 2
    • 44349150888 scopus 로고    scopus 로고
    • Are CT scans carcinogenic?
    • Mezrich R. Are CT scans carcinogenic?. J Am Coll Radiol 5 (2008) 691-693
    • (2008) J Am Coll Radiol , vol.5 , pp. 691-693
    • Mezrich, R.1
  • 3
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine
    • Mettler F., Huda W., Yoshizumi T., et al. Effective doses in radiology and diagnostic nuclear medicine. Radiology 248 (2008) 254-263
    • (2008) Radiology , vol.248 , pp. 254-263
    • Mettler, F.1    Huda, W.2    Yoshizumi, T.3
  • 4
    • 33846493535 scopus 로고    scopus 로고
    • Urinary stone disease: Comparison of standard-dose and low-dose with 4D MDCT tube current modulation
    • Mulkens T., Daineffe S., Wijngaert R., et al. Urinary stone disease: Comparison of standard-dose and low-dose with 4D MDCT tube current modulation. AJR Am J Roentgenol 188 (2007) 553-562
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 553-562
    • Mulkens, T.1    Daineffe, S.2    Wijngaert, R.3
  • 5
    • 33645765988 scopus 로고    scopus 로고
    • What are the risks from medical x-rays and other low dose radiation?
    • Wall B., Kendall G., Edwards A., et al. What are the risks from medical x-rays and other low dose radiation?. Br J Radiol 79 (2006) 285-294
    • (2006) Br J Radiol , vol.79 , pp. 285-294
    • Wall, B.1    Kendall, G.2    Edwards, A.3
  • 6
    • 44349114931 scopus 로고    scopus 로고
    • Exposure to ionizing radiation from cardiovascular imaging and therapeutic procedures may be a considerable unrecognized risk for subsequent cancer development
    • Karatzis E., and Danias P. Exposure to ionizing radiation from cardiovascular imaging and therapeutic procedures may be a considerable unrecognized risk for subsequent cancer development. Am Coll Radiol 5 (2008) 694-695
    • (2008) Am Coll Radiol , vol.5 , pp. 694-695
    • Karatzis, E.1    Danias, P.2
  • 8
    • 0033104412 scopus 로고    scopus 로고
    • Can noncontrast helical computed tomography replace intravenous urography for evaluation of patients with acute urinary tract colic?
    • Chen M., and Zagoria R. Can noncontrast helical computed tomography replace intravenous urography for evaluation of patients with acute urinary tract colic?. J Emerg Med 17 (1999) 299-303
    • (1999) J Emerg Med , vol.17 , pp. 299-303
    • Chen, M.1    Zagoria, R.2
  • 9
    • 57449086281 scopus 로고    scopus 로고
    • Comparison of 0.625mm source CT images versus 5mm thick reconstructed images in the evaluation for renal calculi in at risk patients. The 93rd Scientific Assembly and Annual Meeting of the Radiological Society of North America
    • Berkenblit R., Lerer D., Moses M., et al. Comparison of 0.625mm source CT images versus 5mm thick reconstructed images in the evaluation for renal calculi in at risk patients. The 93rd Scientific Assembly and Annual Meeting of the Radiological Society of North America. Abstract: RSNA Scientific Program (2007) 809
    • (2007) Abstract: RSNA Scientific Program , pp. 809
    • Berkenblit, R.1    Lerer, D.2    Moses, M.3
  • 10
    • 30844472231 scopus 로고    scopus 로고
    • Urinary calculi: improved detection and characterization with thin-slice multidetector CT
    • Ketelslegers E., and Van Beers B. Urinary calculi: improved detection and characterization with thin-slice multidetector CT. Eur Radiol 16 (2006) 161-165
    • (2006) Eur Radiol , vol.16 , pp. 161-165
    • Ketelslegers, E.1    Van Beers, B.2
  • 11
    • 33750448339 scopus 로고    scopus 로고
    • Multidetector CT of the kidney
    • Coppenrath E., and Mueller-Lisse U. Multidetector CT of the kidney. Eur Radiol 16 (2006) 2603-2611
    • (2006) Eur Radiol , vol.16 , pp. 2603-2611
    • Coppenrath, E.1    Mueller-Lisse, U.2
  • 13
    • 33947704171 scopus 로고    scopus 로고
    • Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic
    • Poletti P., Platon A., Rutschmann O., et al. Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic. AJR Am J Roentgenol 188 (2007) 927-933
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 927-933
    • Poletti, P.1    Platon, A.2    Rutschmann, O.3
  • 14
    • 17644389579 scopus 로고    scopus 로고
    • Detection of urinary tract stones at low-radiation-dose CT with Z-axis automatic tube current modulation: phantom and clinical studies
    • Kalra M., Maher M., D'Souza R., et al. Detection of urinary tract stones at low-radiation-dose CT with Z-axis automatic tube current modulation: phantom and clinical studies. Radiology 235 (2005) 523-529
    • (2005) Radiology , vol.235 , pp. 523-529
    • Kalra, M.1    Maher, M.2    D'Souza, R.3
  • 15
    • 39749113025 scopus 로고    scopus 로고
    • Characterization of human renal stones with MDCT: Advantage of dual energy and limitations due to respiratory motion
    • Grosjean R., Sauer B., Guerra R., et al. Characterization of human renal stones with MDCT: Advantage of dual energy and limitations due to respiratory motion. AJR Am J Roentgenol 190 (2008) 720-728
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 720-728
    • Grosjean, R.1    Sauer, B.2    Guerra, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.