메뉴 건너뛰기




Volumn , Issue , 2008, Pages 919-922

Two frequency radar sensor for non-contact vital signal monitor

Author keywords

Doppler radar; ECG; Heart; Heartbeat; Vital signs

Indexed keywords

DOPPLER RADAR; MICROWAVES; SENSORS;

EID: 57349175901     PISSN: 0149645X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MWSYM.2008.4632983     Document Type: Conference Paper
Times cited : (25)

References (8)
  • 1
    • 0027022165 scopus 로고
    • Microwave sensing of physiological movement and volume change: A review
    • December
    • J. C. Lin, "Microwave sensing of physiological movement and volume change: A review," Bioelectromagnetics, vol. 13, pp. 557-565, December 1992.
    • (1992) Bioelectromagnetics , vol.13 , pp. 557-565
    • Lin, J.C.1
  • 2
    • 0027606448 scopus 로고
    • Monitoring of electrocardiograms in bed without utilizing body surface electrodes
    • Jun
    • M.Ishijima. : "Monitoring of electrocardiograms in bed without utilizing body surface electrodes", IEEE Trans. Biomed. Eng., vol. 40, no. 6, pp. 593-594, Jun. 1993.
    • (1993) IEEE Trans. Biomed. Eng , vol.40 , Issue.6 , pp. 593-594
    • Ishijima, M.1
  • 3
    • 38649119753 scopus 로고    scopus 로고
    • Non-contact heartbeat and respiration sensor using capacitive sensor with Colpitts oscillator
    • Jan
    • J.H. Oum, S.E. Lee, D.-W. Kim, S. Hong, "Non-contact heartbeat and respiration sensor using capacitive sensor with Colpitts oscillator," Electronics Letters, vol. 44, issue 2, pp. 87-88, Jan. 2008
    • (2008) Electronics Letters , vol.44 , Issue.2 , pp. 87-88
    • Oum, J.H.1    Lee, S.E.2    Kim, D.-W.3    Hong, S.4
  • 4
    • 0025070460 scopus 로고
    • Laser apexcardiogram in healthy young men: A comparative study with the conventional method
    • A. Ronaszeki, A. E. Aubert, and H. de Geest, "Laser apexcardiogram in healthy young men: a comparative study with the conventional method," Acta Cardiologica, vol. 45, no. 3, pp. 203-210, 1990
    • (1990) Acta Cardiologica , vol.45 , Issue.3 , pp. 203-210
    • Ronaszeki, A.1    Aubert, A.E.2    de Geest, H.3
  • 5
    • 0026139979 scopus 로고
    • Reconstruction of out-of-plane cardiac displacement patterns as observed on the chest wall during various phases of ECG by capacitance transducer
    • G.Ramachandran, S.Swarnamani, M. Singh, "Reconstruction of out-of-plane cardiac displacement patterns as observed on the chest wall during various phases of ECG by capacitance transducer," IEEE Transactions on Biomedical Engineering, vol. 38, no. 4, pp. 383-385, 1991
    • (1991) IEEE Transactions on Biomedical Engineering , vol.38 , Issue.4 , pp. 383-385
    • Ramachandran, G.1    Swarnamani, S.2    Singh, M.3
  • 6
    • 33646739294 scopus 로고    scopus 로고
    • Frequency-Tuning Technique for Remote Detection of heartbeat and Respiration Using Low-Power Double-Sideband Transmission in the Ka-B and
    • Y. Xiao, J. Lin, O. Boric-Lubecke, V.M. Lubecke, "Frequency-Tuning Technique for Remote Detection of heartbeat and Respiration Using Low-Power Double-Sideband Transmission in the Ka-B and," IEEE Transactions on Microwave Theory and Techniques, vol. 54, no. 5, pp. 2023-2032, 2006
    • (2006) IEEE Transactions on Microwave Theory and Techniques , vol.54 , Issue.5 , pp. 2023-2032
    • Xiao, Y.1    Lin, J.2    Boric-Lubecke, O.3    Lubecke, V.M.4
  • 7
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
    • S. Gabriel, R. W. Lau and C. Gabriel, "The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz," Phys. Med. Biol. 41 (1996), 2251-2269.
    • (1996) Phys. Med. Biol , vol.41 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 8
    • 77950688014 scopus 로고    scopus 로고
    • An Internet resource for the calculation of the Dielectric Properties of Body Tissues in the frequency range 10Hz-100GHz
    • Italian National Research Council, Institute for Applied Physics, URL
    • Italian National Research Council, Institute for Applied Physics, "An Internet resource for the calculation of the Dielectric Properties of Body Tissues in the frequency range 10Hz-100GHz," Internet document; URL: http://niremf.ifac.cnr.it/tissprop/
    • Internet document


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.