Freedom from complications related to dual ball-and-cage mechanical valve prostheses despite thirty years without anticoagulation

Author keywords

Debakey surgitool; Prosthetic valve; Starr Edwards; Warfarin

Indexed keywords

ACETYLSALICYLIC ACID; ANTICOAGULANT AGENT; HEPARIN; WARFARIN;

EID: 57349152145     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2007.172155     Document Type: Article
Times cited : (3)

References (10)
  • 1
    • 0033935132 scopus 로고    scopus 로고
    • Evolution of mechanical heart valves
    • DeWall R, Qasim N, Carr L. Evolution of mechanical heart valves. Ann Thorac Surg 2000;69:1612-1621.
    • (2000) Ann Thorac Surg , vol.69 , pp. 1612-1621
    • DeWall, R.1    Qasim, N.2    Carr, L.3
  • 2
    • 0025044840 scopus 로고
    • Asymptomatic strut fracture in DeBakey-Surgitool aortic valves
    • Von Der Emde J, Eberlein U, Brem J. Asymptomatic strut fracture in DeBakey-Surgitool aortic valves. Texas Heart Inst J 1990;17:223-227.
    • (1990) Texas Heart Inst J , vol.17 , pp. 223-227
    • Von Der Emde, J.1    Eberlein, U.2    Brem, J.3
  • 3
    • 8844256583 scopus 로고    scopus 로고
    • DeBakey Surgitool mechanical heart valve prosthesis, explanted at 32 years
    • Butany J, Naseemuddin A, Nair V, Feindel C. DeBakey Surgitool mechanical heart valve prosthesis, explanted at 32 years. Images Cardiovasc Path 2004;13:345-346.
    • (2004) Images Cardiovasc Path , vol.13 , pp. 345-346
    • Butany, J.1    Naseemuddin, A.2    Nair, V.3    Feindel, C.4
  • 4
    • 0343488401 scopus 로고    scopus 로고
    • Thirty years survival after double valve replacement with Starr-Edwards prostheses in aortic and mitral position
    • Godje O, Brenner P, Fischlein T, Reichart B. Thirty years survival after double valve replacement with Starr-Edwards prostheses in aortic and mitral position. Eur J Cardiothorac Surg 1997;11:391-393.
    • (1997) Eur J Cardiothorac Surg , vol.11 , pp. 391-393
    • Godje, O.1    Brenner, P.2    Fischlein, T.3    Reichart, B.4
  • 5
    • 34548395883 scopus 로고    scopus 로고
    • Extended (31 years) durability of a Starr-Edwards prosthesis in the mitral position
    • doi: 10.1510/icvts.2006.146399
    • Tarzia V, Bottio T, Testolin L, Gerosa G. Extended (31 years) durability of a Starr-Edwards prosthesis in the mitral position. Interact CardioVasc Thorac Surg doi: 10.1510/icvts.2006.146399.
    • Interact CardioVasc Thorac Surg
    • Tarzia, V.1    Bottio, T.2    Testolin, L.3    Gerosa, G.4
  • 7
    • 33846892533 scopus 로고    scopus 로고
    • An old friend is still at work: 34-year-old well functioning Starr-Edwards aortic prosthesis without anticoagulation
    • Ikizler M, Birdane A, Sevin B. An old friend is still at work: 34-year-old well functioning Starr-Edwards aortic prosthesis without anticoagulation. Int J Card 2007;116:e1-e3.
    • (2007) Int J Card , vol.116
    • Ikizler, M.1    Birdane, A.2    Sevin, B.3
  • 8
    • 85118092416 scopus 로고    scopus 로고
    • Bonow RO, Carabello BA, Chatterjee K, de Leon AC, Faxon DP, Freed MD, Gaasch WH, Lytle BW, Nishimura RA, O'Gara PT, O'Rourke RA, Otto CM, Shah PM, Shanewise JS, Smith SC, Jacobs AK, Adams CD, Anderson JL, Antman EM, Fuster V, Halperin JL, Hiratska LF, Hunt SA, Lytle BW, Page RL, Riegel B. ACC/AHA 2006 practice guidelines for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association task force on practice management of patients with valvulvar heart disease. J Am Coll Card 2006;48:598-675.
    • Bonow RO, Carabello BA, Chatterjee K, de Leon AC, Faxon DP, Freed MD, Gaasch WH, Lytle BW, Nishimura RA, O'Gara PT, O'Rourke RA, Otto CM, Shah PM, Shanewise JS, Smith SC, Jacobs AK, Adams CD, Anderson JL, Antman EM, Fuster V, Halperin JL, Hiratska LF, Hunt SA, Lytle BW, Page RL, Riegel B. ACC/AHA 2006 practice guidelines for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association task force on practice management of patients with valvulvar heart disease. J Am Coll Card 2006;48:598-675.
  • 10
    • 0022635156 scopus 로고    scopus 로고
    • Antiplatelet drugs and the incidence of thromboembolic complications of the St. Jude Medical aortic prosthesis in patients with rheumatic heart disease
    • Ribeiro PA, Al Zaibag M, Idris M, Al Kasab S, Davies G, Mashat E, Wareham E, Al Fagih M. Antiplatelet drugs and the incidence of thromboembolic complications of the St. Jude Medical aortic prosthesis in patients with rheumatic heart disease. J Thorac Cardiovasc Surg 1996;91:92-98.
    • (1996) J Thorac Cardiovasc Surg , vol.91 , pp. 92-98
    • Ribeiro, P.A.1    Al Zaibag, M.2    Idris, M.3    Al Kasab, S.4    Davies, G.5    Mashat, E.6    Wareham, E.7    Al Fagih, M.8