메뉴 건너뛰기




Volumn 5, Issue 12, 2008, Pages 1755-1757

Defibrillator indications and implantation in young children

Author keywords

Children; Congenital heart disease; Implantable cardioverter defibrillator; Pediatrics; Subcutaneous lead

Indexed keywords

ARTICLE; AUTOMATED EXTERNAL DEFIBRILLATOR; CARDIOVASCULAR RISK; CHILD; COMPUTER MODEL; DISEASE MODEL; EPICARDIUM; HEART DEATH; HEART PACING; HEART VENTRICLE TACHYCARDIA; HUMAN; LIFE EXPECTANCY; NON INVASIVE PROCEDURE; NONHUMAN; PATIENT ASSESSMENT; PRIMARY PREVENTION; PRIORITY JOURNAL; PSYCHOSOCIAL DEVELOPMENT; RISK ASSESSMENT; SUDDEN DEATH; TREATMENT INDICATION;

EID: 57249115881     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2008.07.027     Document Type: Article
Times cited : (21)

References (16)
  • 1
    • 43049118272 scopus 로고    scopus 로고
    • Results of a multicenter retrospective implantable cardioverter defibrillator registry of pediatric and congenital heart disease patients
    • Berul C.I., Van Hare G., Kertesz N.J., et al. Results of a multicenter retrospective implantable cardioverter defibrillator registry of pediatric and congenital heart disease patients. J Am Coll Cardiol 51 (2008) 1685-1691
    • (2008) J Am Coll Cardiol , vol.51 , pp. 1685-1691
    • Berul, C.I.1    Van Hare, G.2    Kertesz, N.J.3
  • 2
    • 0029979331 scopus 로고    scopus 로고
    • Five-year experience with implantable defibrillators in children
    • Hamilton R.M., Dorian P., Gow R.M., et al. Five-year experience with implantable defibrillators in children. Am J Cardiol 77 (1996) 524-526
    • (1996) Am J Cardiol , vol.77 , pp. 524-526
    • Hamilton, R.M.1    Dorian, P.2    Gow, R.M.3
  • 3
    • 0742324990 scopus 로고    scopus 로고
    • Implications of implantable cardioverter defibrillator therapy in congenital heart disease and pediatrics
    • Alexander M.E., Cecchin F., Walsh E.P., et al. Implications of implantable cardioverter defibrillator therapy in congenital heart disease and pediatrics. J Cardiovasc Electrophysiol 15 (2004) 72-76
    • (2004) J Cardiovasc Electrophysiol , vol.15 , pp. 72-76
    • Alexander, M.E.1    Cecchin, F.2    Walsh, E.P.3
  • 4
    • 0037109150 scopus 로고    scopus 로고
    • ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines)
    • Gregoratos G., Abrams J., Epstein A.E., et al. ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines). Circulation 106 (2002) 2145-2161
    • (2002) Circulation , vol.106 , pp. 2145-2161
    • Gregoratos, G.1    Abrams, J.2    Epstein, A.E.3
  • 5
    • 1342280420 scopus 로고    scopus 로고
    • Potential benefit from ICD therapy in children and young adolescents
    • Gradaus R., Wollmann C., Köbe J., et al. Potential benefit from ICD therapy in children and young adolescents. Heart 90 (2004) 328-329
    • (2004) Heart , vol.90 , pp. 328-329
    • Gradaus, R.1    Wollmann, C.2    Köbe, J.3
  • 6
    • 3242742134 scopus 로고    scopus 로고
    • High incidence of appropriate and inappropriate ICD therapies in children and adolescents
    • Korte T., Koditz H., Niehaus M., et al. High incidence of appropriate and inappropriate ICD therapies in children and adolescents. Pacing Clin Electrophysiol 27 (2004) 924-932
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 924-932
    • Korte, T.1    Koditz, H.2    Niehaus, M.3
  • 7
    • 0027528936 scopus 로고
    • Sudden cardiac death and the use of ICDs in pediatric patients. The Pediatric Electrophysiology Society
    • Silka M.J., Kron J., Dunnigan A., and Dick II M. Sudden cardiac death and the use of ICDs in pediatric patients. The Pediatric Electrophysiology Society. Circulation 87 (1993) 800-807
    • (1993) Circulation , vol.87 , pp. 800-807
    • Silka, M.J.1    Kron, J.2    Dunnigan, A.3    Dick II, M.4
  • 8
    • 0035691221 scopus 로고    scopus 로고
    • Minimally invasive cardioverter defibrillator implantation for children
    • Berul C.I., Triedman J.K., Forbess J., et al. Minimally invasive cardioverter defibrillator implantation for children. Pacing Clin Electrophysiol 24 (2001) 1789-1794
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 1789-1794
    • Berul, C.I.1    Triedman, J.K.2    Forbess, J.3
  • 9
    • 0035107693 scopus 로고    scopus 로고
    • Nonthoracotomy implantable cardioverter defibrillator placement in children: use of subcutaneous array leads and abdominally placed implantable cardioverter defibrillators in children
    • Gradaus R., Hammel D., Kotthoff S., et al. Nonthoracotomy implantable cardioverter defibrillator placement in children: use of subcutaneous array leads and abdominally placed implantable cardioverter defibrillators in children. J Cardiovasc Electrophysiol 12 (2001) 356-360
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 356-360
    • Gradaus, R.1    Hammel, D.2    Kotthoff, S.3
  • 10
    • 0035171589 scopus 로고    scopus 로고
    • Implantable cardioverter defibrillator in a 4-month-old infant with cardiac arrest associated with a vascular heart tumor
    • Thøgersen A.M., Helvind M., Jensen T., et al. Implantable cardioverter defibrillator in a 4-month-old infant with cardiac arrest associated with a vascular heart tumor. Pacing Clin Electrophysiol 24 (2001) 1699-1700
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 1699-1700
    • Thøgersen, A.M.1    Helvind, M.2    Jensen, T.3
  • 11
    • 33645099458 scopus 로고    scopus 로고
    • A multicenter experience with novel implantable cardioverter-defibrillator configurations in pediatric and congenital heart disease
    • Stephenson E.A., Batra A.S., Knilans T.K., et al. A multicenter experience with novel implantable cardioverter-defibrillator configurations in pediatric and congenital heart disease. J Cardiovasc Electrophysiol 17 (2006) 41-46
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 41-46
    • Stephenson, E.A.1    Batra, A.S.2    Knilans, T.K.3
  • 12
    • 37549050873 scopus 로고    scopus 로고
    • Acute defibrillation performance of a novel, non-transvenous shock pathway in adult ICD indicated patients
    • Lieberman R., Havel W.J., Rashba E., et al. Acute defibrillation performance of a novel, non-transvenous shock pathway in adult ICD indicated patients. Heart Rhythm 5 (2008) 28-34
    • (2008) Heart Rhythm , vol.5 , pp. 28-34
    • Lieberman, R.1    Havel, W.J.2    Rashba, E.3
  • 13
    • 30344469705 scopus 로고    scopus 로고
    • Defibrillation energy requirements using a left anterior chest cutaneous to subcutaneous shocking vector: implications for a total subcutaneous implantable defibrillator
    • Burke M.C., Coman J.A., Cates A.W., et al. Defibrillation energy requirements using a left anterior chest cutaneous to subcutaneous shocking vector: implications for a total subcutaneous implantable defibrillator. Heart Rhythm 2 (2005) 1332-1338
    • (2005) Heart Rhythm , vol.2 , pp. 1332-1338
    • Burke, M.C.1    Coman, J.A.2    Cates, A.W.3
  • 14
    • 33645231845 scopus 로고    scopus 로고
    • Innovative techniques for placement of implantable cardioverter-defibrillator leads in patients with limited venous access to the heart
    • Cannon B.C., Friedman R.A., Fenrich A.L., et al. Innovative techniques for placement of implantable cardioverter-defibrillator leads in patients with limited venous access to the heart. Pacing Clin Electrophysiol 29 (2006) 181-187
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 181-187
    • Cannon, B.C.1    Friedman, R.A.2    Fenrich, A.L.3
  • 15
    • 34250307058 scopus 로고    scopus 로고
    • Initial experience with implantable cardioverter defibrillator systems using epicardial and pleural electrodes in pediatric patients
    • Bauersfeld U., Tomaske M., Dodge-Khatami A., et al. Initial experience with implantable cardioverter defibrillator systems using epicardial and pleural electrodes in pediatric patients. Ann Thorac Surg 84 (2007) 303-305
    • (2007) Ann Thorac Surg , vol.84 , pp. 303-305
    • Bauersfeld, U.1    Tomaske, M.2    Dodge-Khatami, A.3
  • 16
    • 3042773708 scopus 로고    scopus 로고
    • Patient, procedural, and hardware factors associated with pacemaker lead failures in pediatrics and congenital heart disease
    • Fortescue E.B., Berul C.I., Cecchin F., et al. Patient, procedural, and hardware factors associated with pacemaker lead failures in pediatrics and congenital heart disease. Heart Rhythm 1 (2004) 150-159
    • (2004) Heart Rhythm , vol.1 , pp. 150-159
    • Fortescue, E.B.1    Berul, C.I.2    Cecchin, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.