메뉴 건너뛰기




Volumn 29, Issue 6, 2008, Pages 994-1000

Volume measurement using the Polhemus FastSCAN 3D laser scanning: A novel application for burns clinical research

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARM; ARTICLE; BURN; CLINICAL ARTICLE; CLINICAL RESEARCH; CLINICAL TRIAL; COMPUTER PROGRAM; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; HUMAN; IMAGE QUALITY; LASER; MALE; PATIENT MONITORING; QUALITY CONTROL; QUANTITATIVE ANALYSIS; RELIABILITY; SURVIVOR; THREE DIMENSIONAL IMAGING; VALIDATION STUDY; VOLUMETRY;

EID: 57149091560     PISSN: 1559047X     EISSN: 15590488     Source Type: Journal    
DOI: 10.1097/BCR.0b013e31818b9e97     Document Type: Article
Times cited : (22)

References (22)
  • 2
    • 0024367686 scopus 로고
    • The effect of mucosal integrity and mesenteric blood flow on enteric translocation of microorganisms in cutaneous thermal injury
    • Herndon DN, Morris SE, Coffey JA Jr, et al. The effect of mucosal integrity and mesenteric blood flow on enteric translocation of microorganisms in cutaneous thermal injury. Prog Clin Biol Res 1989;308:377-82.
    • (1989) Prog Clin Biol Res , vol.308 , pp. 377-382
    • Herndon, D.N.1    Morris, S.E.2    Coffey Jr, J.A.3
  • 3
    • 19544387170 scopus 로고    scopus 로고
    • The burn edema process: Current concepts
    • Demling RH. The burn edema process: current concepts. J Burn Care Rehabil 2005;26:207-27.
    • (2005) J Burn Care Rehabil , vol.26 , pp. 207-227
    • Demling, R.H.1
  • 4
    • 0037308284 scopus 로고    scopus 로고
    • Concurrent validity of upper-extremity volume estimates: Comparison of calculated volume derived from girth measurements and water displacement volume
    • Karges JR, Mark BE, Stikeleather SJ, Worrell TW. Concurrent validity of upper-extremity volume estimates: comparison of calculated volume derived from girth measurements and water displacement volume. Phys Ther 2003;83: 134-45.
    • (2003) Phys Ther , vol.83 , pp. 134-145
    • Karges, J.R.1    Mark, B.E.2    Stikeleather, S.J.3    Worrell, T.W.4
  • 5
    • 7044264450 scopus 로고    scopus 로고
    • Validity and intra- and inter-observer reliability of an indirect volume measurements in patients with upper extremity lymphedema
    • Meijer RS, Rietman JS, Geertzen JH, Bosmans JC, Dijkstra PU. Validity and intra- and inter-observer reliability of an indirect volume measurements in patients with upper extremity lymphedema. Lymphology 2004;37:127-33.
    • (2004) Lymphology , vol.37 , pp. 127-133
    • Meijer, R.S.1    Rietman, J.S.2    Geertzen, J.H.3    Bosmans, J.C.4    Dijkstra, P.U.5
  • 6
    • 0034335232 scopus 로고    scopus 로고
    • Assessment of limb volume by manual and automated methods in patients with limb edema or lymphedema
    • Mayrovitz HN, Sims N, Macdonald J. Assessment of limb volume by manual and automated methods in patients with limb edema or lymphedema. Adv Skin Wound Care 2000;13: 272-6.
    • (2000) Adv Skin Wound Care , vol.13 , pp. 272-276
    • Mayrovitz, H.N.1    Sims, N.2    Macdonald, J.3
  • 7
    • 0346007947 scopus 로고    scopus 로고
    • Use of hand held laser scanning in the assessment of facial swelling: A preliminary study
    • Harrison JA, Nixon MA, Fright WR, Snape L. Use of hand held laser scanning in the assessment of facial swelling: a preliminary study. Br J Oral Maxillofac Surg 2004;42:8-17.
    • (2004) Br J Oral Maxillofac Surg , vol.42 , pp. 8-17
    • Harrison, J.A.1    Nixon, M.A.2    Fright, W.R.3    Snape, L.4
  • 8
    • 0034071314 scopus 로고    scopus 로고
    • Calibration of position and angular data from a magnetic tracking device
    • Day JS, Murdoch DJ, Dumas GA. Calibration of position and angular data from a magnetic tracking device. J Biomech 2000;33:1039-45.
    • (2000) J Biomech , vol.33 , pp. 1039-1045
    • Day, J.S.1    Murdoch, D.J.2    Dumas, G.A.3
  • 9
    • 0034022105 scopus 로고    scopus 로고
    • Kinematics of human arm reconstructed from spatial tracking recordings
    • Biryukova EV, Roby-Brami A, Frolov AA, Mokhtari M. Kinematics of human arm reconstructed from spatial tracking recordings. J Biomech 2000;33:985-95.
    • (2000) J Biomech , vol.33 , pp. 985-995
    • Biryukova, E.V.1    Roby-Brami, A.2    Frolov, A.A.3    Mokhtari, M.4
  • 10
    • 57149114244 scopus 로고    scopus 로고
    • available from, accessed 3 Dec 2007
    • Polhemus I. Polhemus: innovation in morion; available from http:/www.polhemus.com/?page=Scanning-Case-Studies; accessed 3 Dec 2007.
    • Polhemus: Innovation in morion
    • Polhemus, I.1
  • 11
    • 0030472896 scopus 로고    scopus 로고
    • Development and evaluation of a precision forearm and hand volumeter and measuring cylinder
    • Boland R, Adams R. Development and evaluation of a precision forearm and hand volumeter and measuring cylinder. J Hand Ther 1996;9:349-58.
    • (1996) J Hand Ther , vol.9 , pp. 349-358
    • Boland, R.1    Adams, R.2
  • 13
    • 0027630851 scopus 로고
    • The effect of water temperature on hand volume during volumetric measurement using the water displacement method
    • King TI II. The effect of water temperature on hand volume during volumetric measurement using the water displacement method. J Hand Ther 1993;6:202-4.
    • (1993) J Hand Ther , vol.6 , pp. 202-204
    • King II, T.I.1
  • 14
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0025048927 scopus 로고
    • A note on the use of the intraclass correlation coeffieicnt in the evaluation of agreement between two methods of measurement
    • Bland JM, Altman DG. A note on the use of the intraclass correlation coeffieicnt in the evaluation of agreement between two methods of measurement. Comput Biol Med 1990;20:337-40.
    • (1990) Comput Biol Med , vol.20 , pp. 337-340
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 34347375489 scopus 로고    scopus 로고
    • Agreement between methods of measurement with multiple observations per individual
    • Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 2007;17:571-82.
    • (2007) J Biopharm Stat , vol.17 , pp. 571-582
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 0031907463 scopus 로고    scopus 로고
    • Accuracy and precision of volumetric determinations using two commercial CAD systems for prosthetics: A technical note
    • Johansson S, Oberg T. Accuracy and precision of volumetric determinations using two commercial CAD systems for prosthetics: a technical note. J Rehabil Res Dev 1998;35: 27-33.
    • (1998) J Rehabil Res Dev , vol.35 , pp. 27-33
    • Johansson, S.1    Oberg, T.2
  • 21
    • 8844219726 scopus 로고    scopus 로고
    • The validity and reliability of the perometer in evaluating human knee volume
    • Man IOW, Markland KL, Morrissey MC. The validity and reliability of the perometer in evaluating human knee volume. Clin Physiol Funct Imaging 2004;24:352-8.
    • (2004) Clin Physiol Funct Imaging , vol.24 , pp. 352-358
    • Man, I.O.W.1    Markland, K.L.2    Morrissey, M.C.3
  • 22
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 1995;346:1084-7.
    • (1995) Lancet , vol.346 , pp. 1084-1087
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.