메뉴 건너뛰기




Volumn 16, Issue , 2008, Pages 56-66

The importance of loading frequency, rate and vibration for enhancing bone adaptation and implant osseointegration

Author keywords

Bone adaptation; Implant; Loading frequency; Osseointegration; Strain rate; Vibration

Indexed keywords

ARTICLE; BIOMECHANICS; BONE; BONE REGENERATION; BONE STRENGTH; BONE STRESS; EXPERIMENTAL STUDY; HUMAN; IMPLANT; LIMB; MECHANOTRANSDUCTION; MEDICAL RESEARCH; NONHUMAN; SYSTEMATIC REVIEW; VIBRATION;

EID: 57149090491     PISSN: 14732262     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (40)

References (58)
  • 2
    • 0032895922 scopus 로고    scopus 로고
    • Mechanotransduction in bone - role of the lacuno-canalicular network
    • Burger EH, Klein-Nulend J (1999) Mechanotransduction in bone - role of the lacuno-canalicular network. FASEB J 13: S101-S112.
    • (1999) FASEB J , vol.13
    • Burger, E.H.1    Klein-Nulend, J.2
  • 3
    • 0021960062 scopus 로고
    • Bone remodeling in response to in vivo fatigue microdamage
    • Burr DB, Martin RB, Schaffler MB, Radin EL (1985) Bone remodeling in response to in vivo fatigue microdamage. J Biomech 18: 189-200.
    • (1985) J Biomech , vol.18 , pp. 189-200
    • Burr, D.B.1    Martin, R.B.2    Schaffler, M.B.3    Radin, E.L.4
  • 5
    • 33749525465 scopus 로고    scopus 로고
    • Low-amplitude, broad-frequency vibration effects on cortical bone formation in mice
    • Castillo AB, Alam I, Tanaka SM, Levenda J, Li J, Warden SJ, Turner CH (2006) Low-amplitude, broad-frequency vibration effects on cortical bone formation in mice. Bone 39: 1087-1096.
    • (2006) Bone , vol.39 , pp. 1087-1096
    • Castillo, A.B.1    Alam, I.2    Tanaka, S.M.3    Levenda, J.4    Li, J.5    Warden, S.J.6    Turner, C.H.7
  • 6
    • 0033104459 scopus 로고    scopus 로고
    • Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing
    • Claes LE, Heigele CA (1999) Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing. J Biomech 32: 255-266.
    • (1999) J Biomech , vol.32 , pp. 255-266
    • Claes, L.E.1    Heigele, C.A.2
  • 7
    • 0032983135 scopus 로고    scopus 로고
    • Bone poroelasticity
    • Cowin SC (1999) Bone poroelasticity. J Biomech 32: 217-238.
    • (1999) J Biomech , vol.32 , pp. 217-238
    • Cowin, S.C.1
  • 8
    • 0036122913 scopus 로고    scopus 로고
    • Mechanosensation and fluid transport in living bone
    • Cowin SC (2002) Mechanosensation and fluid transport in living bone. J Musculoskelet Neuronal Interact 2: 256-260.
    • (2002) J Musculoskelet Neuronal Interact , vol.2 , pp. 256-260
    • Cowin, S.C.1
  • 9
    • 0141608016 scopus 로고    scopus 로고
    • Understanding peri-implant endosseous healing
    • Davies JE (2003) Understanding peri-implant endosseous healing. J Dent Educ 67: 932-949.
    • (2003) J Dent Educ , vol.67 , pp. 932-949
    • Davies, J.E.1
  • 10
    • 33744969864 scopus 로고    scopus 로고
    • Effect of controlled early implant loading on bone healing and bone mass in guinea pigs, as assessed by micro-CT and histology
    • De Smet E, Jaecques SVN, Wevers M, Jansen JA, Jacobs R, Vander Sloten J, Naert IE (2006) Effect of controlled early implant loading on bone healing and bone mass in guinea pigs, as assessed by micro-CT and histology. Eur J Oral Sci 114: 232-242.
    • (2006) Eur J Oral Sci , vol.114 , pp. 232-242
    • De Smet, E.1    Jaecques, S.V.N.2    Wevers, M.3    Jansen, J.A.4    Jacobs, R.5    Vander Sloten, J.6    Naert, I.E.7
  • 11
    • 34250200457 scopus 로고    scopus 로고
    • Effect of constant strain rate, composed of varying amplitude and frequency, of early loading on peri-implant bone (re)modelling
    • De Smet E, Jaecques SV, Jansen JJ, Walboomers F, Vander Sloten J, Naert IE (2007) Effect of constant strain rate, composed of varying amplitude and frequency, of early loading on peri-implant bone (re)modelling. J Clin Periodontol 34: 618-624.
    • (2007) J Clin Periodontol , vol.34 , pp. 618-624
    • De Smet, E.1    Jaecques, S.V.2    Jansen, J.J.3    Walboomers, F.4    Vander Sloten, J.5    Naert, I.E.6
  • 12
    • 28844442933 scopus 로고    scopus 로고
    • Non-invasive axial loading of mouse tibiae increases cortical bone formation and modifies trabecular organization: A new model to study cortical and cancellous compartments in a single loaded element
    • De Souza RL, Matsuura M, Eckstein F, Rawlinson SCF, Lanyon LE, Pitsillides AA (2005) Non-invasive axial loading of mouse tibiae increases cortical bone formation and modifies trabecular organization: A new model to study cortical and cancellous compartments in a single loaded element. Bone 37: 810-818.
    • (2005) Bone , vol.37 , pp. 810-818
    • De Souza, R.L.1    Matsuura, M.2    Eckstein, F.3    Rawlinson, S.C.F.4    Lanyon, L.E.5    Pitsillides, A.A.6
  • 14
    • 2642519625 scopus 로고    scopus 로고
    • Mechanical signals as regulators of stem cell fate
    • Estes BT, Gimble JM, Guilak F (2004) Mechanical signals as regulators of stem cell fate. Curr Top Dev Biol 60: 91-126.
    • (2004) Curr Top Dev Biol , vol.60 , pp. 91-126
    • Estes, B.T.1    Gimble, J.M.2    Guilak, F.3
  • 15
    • 43449106770 scopus 로고    scopus 로고
    • Mechanical signals modulated vascular endothelial growth factor-A (VEGF-A) alternative splicing in osteoblastic cells through actin polymerization
    • Faure C, Linossier MT, Malaval L, Lafage-Proust MH, Peyroche S, Vico L, Guignandon A (2008) Mechanical signals modulated vascular endothelial growth factor-A (VEGF-A) alternative splicing in osteoblastic cells through actin polymerization. Bone 42: 1092-1101.
    • (2008) Bone , vol.42 , pp. 1092-1101
    • Faure, C.1    Linossier, M.T.2    Malaval, L.3    Lafage-Proust, M.H.4    Peyroche, S.5    Vico, L.6    Guignandon, A.7
  • 16
    • 0031775038 scopus 로고    scopus 로고
    • Mechanical stimulation in the form of vibration prevents postmenopausal bone loss in ovariectomized rats
    • Flieger J, Karachalios T, Khaldi L, Raptou P, and Lyritis G (1998) Mechanical stimulation in the form of vibration prevents postmenopausal bone loss in ovariectomized rats. Calcif Tissue Int 63: 510-514.
    • (1998) Calcif Tissue Int , vol.63 , pp. 510-514
    • Flieger, J.1    Karachalios, T.2    Khaldi, L.3    Raptou, P.4    Lyritis, G.5
  • 17
    • 0033622817 scopus 로고    scopus 로고
    • Quantifying the strain history of bone: Spatial uniformity and self-similarity of low-magnitude strains
    • Fritton SP, McLeod KJ, Rubin CT (2000) Quantifying the strain history of bone: spatial uniformity and self-similarity of low-magnitude strains. J Biomech 33: 317-325.
    • (2000) J Biomech , vol.33 , pp. 317-325
    • Fritton, S.P.1    McLeod, K.J.2    Rubin, C.T.3
  • 18
    • 37249033766 scopus 로고    scopus 로고
    • Application of mechanoregulatory models to simulate peri-implant tissue formation in an in vivo bone chamber
    • Geris L, Vandamme K, Naert I, Vander Sloten J, Duyck J, Van Oosterwyck H (2008) Application of mechanoregulatory models to simulate peri-implant tissue formation in an in vivo bone chamber. J Biomech 41: 145-154.
    • (2008) J Biomech , vol.41 , pp. 145-154
    • Geris, L.1    Vandamme, K.2    Naert, I.3    Vander Sloten, J.4    Duyck, J.5    Van Oosterwyck, H.6
  • 19
    • 0036179760 scopus 로고    scopus 로고
    • Noninvasive loading of the murine tibia: An in vivo model for the study of mechanotransduction
    • Gross TS, Srinivasan S, Liu CC, Clemens TL, Bain SD (2002) Noninvasive loading of the murine tibia: an in vivo model for the study of mechanotransduction. J Bone Miner Res 17: 493-501.
    • (2002) J Bone Miner Res , vol.17 , pp. 493-501
    • Gross, T.S.1    Srinivasan, S.2    Liu, C.C.3    Clemens, T.L.4    Bain, S.D.5
  • 20
    • 0032816748 scopus 로고    scopus 로고
    • Viscoelastic response of the rat loading model: Implications for studies of strain-adaptive bone formation
    • Hsieh YF, Wang T, Turner CH (1999) Viscoelastic response of the rat loading model: implications for studies of strain-adaptive bone formation. Bone 25: 379-382.
    • (1999) Bone , vol.25 , pp. 379-382
    • Hsieh, Y.F.1    Wang, T.2    Turner, C.H.3
  • 21
    • 0035064222 scopus 로고    scopus 로고
    • Effects of loading frequency on mechanically induced bone formation
    • Hsieh YF, Turner CH (2001) Effects of loading frequency on mechanically induced bone formation. J Bone Miner Res 16: 918-924
    • (2001) J Bone Miner Res , vol.16 , pp. 918-924
    • Hsieh, Y.F.1    Turner, C.H.2
  • 22
    • 0026604141 scopus 로고
    • The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
    • Huiskes R, Weinans H, van Rietbergen B (1992) The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop Relat Res 274: 124-134.
    • (1992) Clin Orthop Relat Res , vol.274 , pp. 124-134
    • Huiskes, R.1    Weinans, H.2    van Rietbergen, B.3
  • 23
  • 26
    • 0030804099 scopus 로고    scopus 로고
    • Strain gradients correlate with sites of exercise-induced bone-forming surfaces in the adult skeleton
    • Judex S, Gross TS, Zernicke RF (1997) Strain gradients correlate with sites of exercise-induced bone-forming surfaces in the adult skeleton. J Bone Miner Res 12: 1737-1745.
    • (1997) J Bone Miner Res , vol.12 , pp. 1737-1745
    • Judex, S.1    Gross, T.S.2    Zernicke, R.F.3
  • 27
    • 0036270085 scopus 로고    scopus 로고
    • Proliferation of human-derived osteoblast-like cells depends on the cycle number and frequency of uniaxial strain
    • Kaspar D, Seidl W, Neidlinger-Wilke C, Beck A, Claes L, Ignatius A (2002) Proliferation of human-derived osteoblast-like cells depends on the cycle number and frequency of uniaxial strain. J Biomech 35: 873-880.
    • (2002) J Biomech , vol.35 , pp. 873-880
    • Kaspar, D.1    Seidl, W.2    Neidlinger-Wilke, C.3    Beck, A.4    Claes, L.5    Ignatius, A.6
  • 28
    • 1442324440 scopus 로고    scopus 로고
    • Experimental and finite element analysis of the rat ulnar loading model-correlations between strain and bone formation following fatigue loading
    • Kotha SP, Hsieh YF, Strigel RM, Muller R, Silva MJ (2004) Experimental and finite element analysis of the rat ulnar loading model-correlations between strain and bone formation following fatigue loading. J Biomech 37: 541-548.
    • (2004) J Biomech , vol.37 , pp. 541-548
    • Kotha, S.P.1    Hsieh, Y.F.2    Strigel, R.M.3    Muller, R.4    Silva, M.J.5
  • 29
    • 0036342923 scopus 로고    scopus 로고
    • A mechanoregulation model for tissue differentiation during fracture healing: Analysis of gap size and loading
    • Lacroix D, Prendergast PJ (2002) A mechanoregulation model for tissue differentiation during fracture healing: analysis of gap size and loading. J Biomech 35: 1163-1171.
    • (2002) J Biomech , vol.35 , pp. 1163-1171
    • Lacroix, D.1    Prendergast, P.J.2
  • 30
    • 2342638385 scopus 로고    scopus 로고
    • Rest insertion combined with high-frequency loading enhances osteogenesis
    • LaMothe JM, Zernicke RF (2004) Rest insertion combined with high-frequency loading enhances osteogenesis. J Appl Physiol 96: 1788-1793.
    • (2004) J Appl Physiol , vol.96 , pp. 1788-1793
    • LaMothe, J.M.1    Zernicke, R.F.2
  • 31
    • 16844375549 scopus 로고    scopus 로고
    • Strain rate influences periosteal adaptation in mature bone
    • LaMothe JM, Hamilton NH, Zernicke RF (2005) Strain rate influences periosteal adaptation in mature bone. Med Eng Phys 27: 277-284.
    • (2005) Med Eng Phys , vol.27 , pp. 277-284
    • LaMothe, J.M.1    Hamilton, N.H.2    Zernicke, R.F.3
  • 32
    • 0021676239 scopus 로고
    • Static vs dynamic loads as an influence on bone remodelling
    • Lanyon LE, Rubin CT (1984) Static vs dynamic loads as an influence on bone remodelling. J Biomech 17: 897-905.
    • (1984) J Biomech , vol.17 , pp. 897-905
    • Lanyon, L.E.1    Rubin, C.T.2
  • 33
    • 0036756329 scopus 로고    scopus 로고
    • Validation of a technique for studying functional adaptation of the mouse ulna in response to mechanical loading
    • Lee KC, Maxwell A, Lanyon LE (2002) Validation of a technique for studying functional adaptation of the mouse ulna in response to mechanical loading. Bone 31: 407-412.
    • (2002) Bone , vol.31 , pp. 407-412
    • Lee, K.C.1    Maxwell, A.2    Lanyon, L.E.3
  • 34
    • 0015103499 scopus 로고
    • Reaction of bone to mechanical stimuli. 2. Periosteal and endosteal reaction of tibial diaphysis in rabbit to intermittent loading
    • Liskova M, Hert J (1971) Reaction of bone to mechanical stimuli. 2. Periosteal and endosteal reaction of tibial diaphysis in rabbit to intermittent loading. Folia Morphol (Praha) 19: 301-317.
    • (1971) Folia Morphol (Praha) , vol.19 , pp. 301-317
    • Liskova, M.1    Hert, J.2
  • 35
    • 0030985643 scopus 로고    scopus 로고
    • Strain magnitude related changes in whole bone architecture in growing rats
    • Mosley JR, March BM, Lynch J, Lanyon LE (1997) Strain magnitude related changes in whole bone architecture in growing rats. Bone 20: 191-198.
    • (1997) Bone , vol.20 , pp. 191-198
    • Mosley, J.R.1    March, B.M.2    Lynch, J.3    Lanyon, L.E.4
  • 36
    • 0032190413 scopus 로고    scopus 로고
    • Strain rate as a controlling influence on adaptive modeling in response to dynamic loading of the ulna in growing male rats
    • Mosley JR, Lanyon LE (1998) Strain rate as a controlling influence on adaptive modeling in response to dynamic loading of the ulna in growing male rats. Bone 23: 313-318.
    • (1998) Bone , vol.23 , pp. 313-318
    • Mosley, J.R.1    Lanyon, L.E.2
  • 37
    • 0037262631 scopus 로고    scopus 로고
    • Low-intensity, high-frequency vibration appears to prevent the decrease in strength of the femur and tibia associated with ovariectomy of adult rats
    • Oxlund BS, Ortoft G, Andreassen TT, Oxlund H (2003) Low-intensity, high-frequency vibration appears to prevent the decrease in strength of the femur and tibia associated with ovariectomy of adult rats. Bone 32: 69-77.
    • (2003) Bone , vol.32 , pp. 69-77
    • Oxlund, B.S.1    Ortoft, G.2    Andreassen, T.T.3    Oxlund, H.4
  • 39
  • 40
    • 0031157459 scopus 로고    scopus 로고
    • ESB Research Award 1996. Biophysical stimuli on cells during tissue differentiation at implant interfaces
    • Prendergast PJ, Huiskes R, Søballe K (1997) ESB Research Award 1996. Biophysical stimuli on cells during tissue differentiation at implant interfaces. J Biomech 30: 539-548.
    • (1997) J Biomech , vol.30 , pp. 539-548
    • Prendergast, P.J.1    Huiskes, R.2    Søballe, K.3
  • 41
    • 0035745927 scopus 로고    scopus 로고
    • Recovery periods restore mechanosensitivity to dynamically loaded bone
    • Robling AG, Burr DB, Turner CH (2001) Recovery periods restore mechanosensitivity to dynamically loaded bone. J Exp Biol 204: 3389-3399.
    • (2001) J Exp Biol , vol.204 , pp. 3389-3399
    • Robling, A.G.1    Burr, D.B.2    Turner, C.H.3
  • 42
    • 0021848241 scopus 로고
    • Regulation of bone mass by mechanical strain magnitude
    • Rubin CT and Lanyon LE (1985) Regulation of bone mass by mechanical strain magnitude. Calcif Tissue Int 37: 411-417.
    • (1985) Calcif Tissue Int , vol.37 , pp. 411-417
    • Rubin, C.T.1    Lanyon, L.E.2
  • 43
    • 0027952924 scopus 로고
    • Promotion of bony ingrowth by frequency-specific, low-amplitude mechanical strain
    • Rubin CT, McLeod KJ (1994) Promotion of bony ingrowth by frequency-specific, low-amplitude mechanical strain. Clin Orthop Relat Res 298: 165-174.
    • (1994) Clin Orthop Relat Res , vol.298 , pp. 165-174
    • Rubin, C.T.1    McLeod, K.J.2
  • 45
    • 0034814210 scopus 로고    scopus 로고
    • The anabolic activity of bone tissue, suppressed by disuse, is normalized by brief exposure to extremely low-magnitude mechanical stimuli
    • Rubin C, Xu G, Judex S (2001b) The anabolic activity of bone tissue, suppressed by disuse, is normalized by brief exposure to extremely low-magnitude mechanical stimuli. FASEB J 15: 2225-2229.
    • (2001) FASEB J , vol.15 , pp. 2225-2229
    • Rubin, C.1    Xu, G.2    Judex, S.3
  • 46
    • 0036192588 scopus 로고    scopus 로고
    • Mechanical strain, induced noninvasively in the high-frequency domain, is anabolic to cancellous bone, but not cortical bone
    • Rubin C, Turner AS, Mallinckrodt C, Jerome C, McLeod K, Bain S (2002a) Mechanical strain, induced noninvasively in the high-frequency domain, is anabolic to cancellous bone, but not cortical bone. Bone 30: 445-452.
    • (2002) Bone , vol.30 , pp. 445-452
    • Rubin, C.1    Turner, A.S.2    Mallinckrodt, C.3    Jerome, C.4    McLeod, K.5    Bain, S.6
  • 47
    • 0036155477 scopus 로고    scopus 로고
    • Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention
    • Rubin C, Turner AS, Muller R, Mittra E, McLeod K, Lin W, Qin YX (2002b) Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention. J Bone Miner Res 17: 349-357.
    • (2002) J Bone Miner Res , vol.17 , pp. 349-357
    • Rubin, C.1    Turner, A.S.2    Muller, R.3    Mittra, E.4    McLeod, K.5    Lin, W.6    Qin, Y.X.7
  • 48
    • 0026832935 scopus 로고
    • Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
    • Søballe K, Hansen ES, Rasmussen H, Jorgensen PH, Bunger C (1992) Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res 10: 285-299.
    • (1992) J Orthop Res , vol.10 , pp. 285-299
    • Søballe, K.1    Hansen, E.S.2    Rasmussen, H.3    Jorgensen, P.H.4    Bunger, C.5
  • 49
    • 0036708150 scopus 로고    scopus 로고
    • Low-magnitude mechanical loading becomes osteogenic when rest is inserted between each load cycle
    • Srinivasan S, Weimer DA, Agans SC, Bain SD, Gross TS (2002) Low-magnitude mechanical loading becomes osteogenic when rest is inserted between each load cycle. J Bone Miner Res 17: 1613-1620.
    • (2002) J Bone Miner Res , vol.17 , pp. 1613-1620
    • Srinivasan, S.1    Weimer, D.A.2    Agans, S.C.3    Bain, S.D.4    Gross, T.S.5
  • 50
    • 0037318277 scopus 로고    scopus 로고
    • Stochastic resonance in osteogenic response to mechanical loading
    • Tanaka SM, Alam IM, Turner CH (2003) Stochastic resonance in osteogenic response to mechanical loading. FASEB J 17: 313-314.
    • (2003) FASEB J , vol.17 , pp. 313-314
    • Tanaka, S.M.1    Alam, I.M.2    Turner, C.H.3
  • 51
    • 0028267333 scopus 로고
    • Noninvasive loading of the rat ulna in vivo induces a strain-related modeling response uncomplicated by trauma or periostal pressure
    • Torrance AG, Mosley JR, Suswillo RF, Lanyon LE (1994) Noninvasive loading of the rat ulna in vivo induces a strain-related modeling response uncomplicated by trauma or periostal pressure. Calcif Tissue Int 54: 241-247.
    • (1994) Calcif Tissue Int , vol.54 , pp. 241-247
    • Torrance, A.G.1    Mosley, J.R.2    Suswillo, R.F.3    Lanyon, L.E.4
  • 52
    • 0028024121 scopus 로고
    • Mechanotransduction in bone: Do bone cells act as sensors of fluid flow?
    • Turner CH, Forwood MR, Otter MW (1994) Mechanotransduction in bone: do bone cells act as sensors of fluid flow? FASEB J 8: 875-878.
    • (1994) FASEB J , vol.8 , pp. 875-878
    • Turner, C.H.1    Forwood, M.R.2    Otter, M.W.3
  • 53
    • 0029111672 scopus 로고
    • Mechanotransduction in bone: Role of strain rate
    • Turner SH, Owan I, Takano Y (1995) Mechanotransduction in bone: role of strain rate. Am J Physiol 269: 438-442.
    • (1995) Am J Physiol , vol.269 , pp. 438-442
    • Turner, S.H.1    Owan, I.2    Takano, Y.3
  • 54
    • 0031655751 scopus 로고    scopus 로고
    • Three rules for bone adaptation to mechanical stimuli
    • Turner CH (1998) Three rules for bone adaptation to mechanical stimuli. Bone 23: 399-407.
    • (1998) Bone , vol.23 , pp. 399-407
    • Turner, C.H.1
  • 55
    • 33846378773 scopus 로고    scopus 로고
    • Influence of controlled immediate loading and implant design on peri-implant bone formation
    • Vandamme K, Naert I, Geris L, Vander Sloten J, Puers R, Duyck J (2007) Influence of controlled immediate loading and implant design on peri-implant bone formation. J Clin Periodontol 34: 172-181.
    • (2007) J Clin Periodontol , vol.34 , pp. 172-181
    • Vandamme, K.1    Naert, I.2    Geris, L.3    Vander Sloten, J.4    Puers, R.5    Duyck, J.6
  • 56
    • 0842330737 scopus 로고    scopus 로고
    • Mechanotransduction in the cortical bone is most efficient at loading frequencies of 5-10 Hz
    • Warden SJ, Turner CH (2004) Mechanotransduction in the cortical bone is most efficient at loading frequencies of 5-10 Hz. Bone 34: 261-270.
    • (2004) Bone , vol.34 , pp. 261-270
    • Warden, S.J.1    Turner, C.H.2
  • 57
    • 33749664339 scopus 로고    scopus 로고
    • Low-level mechanical vibrations can influence bone resorption and bone formation in the growing skeleton
    • Xie L, Jacobson JM, Choi ES, Busa B, Donahue LR, Miller LM, Rubin CT, Judex S (2006) Low-level mechanical vibrations can influence bone resorption and bone formation in the growing skeleton. Bone 39: 1059-1066.
    • (2006) Bone , vol.39 , pp. 1059-1066
    • Xie, L.1    Jacobson, J.M.2    Choi, E.S.3    Busa, B.4    Donahue, L.R.5    Miller, L.M.6    Rubin, C.T.7    Judex, S.8
  • 58
    • 0034792594 scopus 로고    scopus 로고
    • A model for strain amplification in the actin cytoskeleton of osteocytes due to fluid drag on pericellular matrix
    • You L, Cowin SC, Schaffler MB, Weinbaum S (2001) A model for strain amplification in the actin cytoskeleton of osteocytes due to fluid drag on pericellular matrix. J Biomech 34: 1375-1386.
    • (2001) J Biomech , vol.34 , pp. 1375-1386
    • You, L.1    Cowin, S.C.2    Schaffler, M.B.3    Weinbaum, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.