메뉴 건너뛰기




Volumn 53, Issue 6, 2008, Pages 270-278

Wireless long-term ECG integrated into clothing

Author keywords

24 7; Bluetooth; Dry electrode; ECG; Integration into clothing; IRDA; Medical; Microsystem; Partly flexible PCB; Pulse wave transit time; Telemedicine

Indexed keywords

CELLULAR TELEPHONE SYSTEMS; ELECTROCARDIOGRAPHY; ELECTROCHROMIC DEVICES; TELEMEDICINE;

EID: 57049175078     PISSN: 00135585     EISSN: None     Source Type: Journal    
DOI: 10.1515/BMT.2008.043     Document Type: Article
Times cited : (7)

References (22)
  • 2
    • 57049149855 scopus 로고    scopus 로고
    • BlueMod+P24, BlueMod+P25 Hardware Reference Manual Revision 1.5, 6 April 2006. Stollmann E+V GmbH, Hamburg.
    • BlueMod+P24, BlueMod+P25 Hardware Reference Manual Revision 1.5, 6 April 2006. Stollmann E+V GmbH, Hamburg.
  • 3
    • 57049085965 scopus 로고    scopus 로고
    • BlueRS+SPP, AT Command Reference, Version 2.0, 25 April 2006. Stollmann E+V GmbH, Hamburg
    • BlueRS+SPP, AT Command Reference, Version 2.0, 25 April 2006. Stollmann E+V GmbH, Hamburg.
  • 5
    • 57049155675 scopus 로고    scopus 로고
    • Bluetooth Body Area network für TeleHomeCare-Anwendungen. Beiträge zur 38. Jahrestagung der Deutschen Gesellschaft für Biomedizinische Technik im VDE - BMT 2004, TU Ilmenau, 22-24 September 2004
    • Parts 1-2, 250-251
    • Despang G, Holland H, Fischer W, Marschner U, Boden R. Bluetooth Body Area network für TeleHomeCare-Anwendungen. Beiträge zur 38. Jahrestagung der Deutschen Gesellschaft für Biomedizinische Technik im VDE - BMT 2004, TU Ilmenau, 22-24 September 2004. Biomed Tech 2004; 49 (Suppl 2, Parts 1-2): 250-251.
    • (2004) Biomed Tech , vol.49 , Issue.SUPPL. 2
    • Despang, G.1    Holland, H.2    Fischer, W.3    Marschner, U.4    Boden, R.5
  • 7
    • 57049107048 scopus 로고    scopus 로고
    • Despang G, Holland H, Fischer W, Jettkant B, Clasbrummel B. Nichtinvasive kontinuierliche Blutdruckmessung mit drahtlosem EKG und Photo-Plethysmographie- Sensor. In: 6. Würzburger Medizintechnik-Kongress 2005, 8-11 May 2005: S347-S350.
    • Despang G, Holland H, Fischer W, Jettkant B, Clasbrummel B. Nichtinvasive kontinuierliche Blutdruckmessung mit drahtlosem EKG und Photo-Plethysmographie- Sensor. In: 6. Würzburger Medizintechnik-Kongress 2005, 8-11 May 2005: S347-S350.
  • 11
    • 57049146514 scopus 로고    scopus 로고
    • Hohensteiner Institute. Available at
    • Hohensteiner Institute. Available at http://www.hohenstein.de/.
  • 12
    • 57049187351 scopus 로고    scopus 로고
    • Kiefer S, Hoffmann K-P, Lorentz A, Despang G, Schmidt M, Weigand C, Norgall T, Couronne R. sensave® - Ergebnisse eines Projekts zur Entwicklung einer modularen, mobilen Multiparameter-Monitoring-Plattform für Herz-Kreislauferkrankungen. In: Proceedings zum 7. Workshop der GMDS- Arbeitsgruppe Mobiles Computing in der Medizin, Augsburg, 20 September 2007: 57-69.
    • Kiefer S, Hoffmann K-P, Lorentz A, Despang G, Schmidt M, Weigand C, Norgall T, Couronne R. sensave® - Ergebnisse eines Projekts zur Entwicklung einer modularen, mobilen Multiparameter-Monitoring-Plattform für Herz-Kreislauferkrankungen. In: Proceedings zum 7. Workshop der GMDS- Arbeitsgruppe "Mobiles Computing in der Medizin", Augsburg, 20 September 2007: 57-69.
  • 13
    • 57049152014 scopus 로고    scopus 로고
    • Klatt C. STELLA-STrechable ELectronics for large area applications. Presentation at Effekte 2008, the 11th Symposia held in Greiz, 28 February 2008.
    • Klatt C. STELLA-STrechable ELectronics for large area applications. Presentation at "Effekte 2008", the 11th Symposia held in Greiz, 28 February 2008.
  • 17
    • 57049173621 scopus 로고    scopus 로고
    • Linz T. Ankontaktierung von elektronischen Bauteilen durch Sticken. Presentation at Effekte 2008, the 11th Symposium held in Greiz, 28 February 2008.
    • Linz T. Ankontaktierung von elektronischen Bauteilen durch Sticken. Presentation at "Effekte 2008", the 11th Symposium held in Greiz, 28 February 2008.
  • 18
    • 57049188523 scopus 로고    scopus 로고
    • Möhring U. Herausforderung Textile Mikrosystemtechnik - Aktuelle Entwicklungen und Trends. Presentation at Effekte 2008, the 11th Symposium held in Greiz, 28 February 2008.
    • Möhring U. Herausforderung Textile Mikrosystemtechnik - Aktuelle Entwicklungen und Trends. Presentation at "Effekte 2008", the 11th Symposium held in Greiz, 28 February 2008.
  • 20
    • 57049108366 scopus 로고    scopus 로고
    • MSP430x15x, MSP430x16x, MSP430x161x, Mixed signal microcontroller, SLA 368D, Texas Instruments, Dallas, TX, USA.
    • MSP430x15x, MSP430x16x, MSP430x161x, Mixed signal microcontroller, SLA 368D, Texas Instruments, Dallas, TX, USA.
  • 21
    • 57649204648 scopus 로고    scopus 로고
    • On-body sensors for personal healthcare, integration examples, implementation challenges and emerging technologies
    • Spekowius G, Wendler T, editors, Dordrecht, The Netherlands: Springer, chapter 28
    • Such O, Muehlsteff J, Pinter R, et al. On-body sensors for personal healthcare, integration examples, implementation challenges and emerging technologies. In: Spekowius G, Wendler T, editors. Advances in Healthcare Technology - Shaping the Future of Medical Care. Dordrecht, The Netherlands: Springer 2006, chapter 28: 463-488.
    • (2006) Advances in Healthcare Technology - Shaping the Future of Medical Care , pp. 463-488
    • Such, O.1    Muehlsteff, J.2    Pinter, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.