메뉴 건너뛰기




Volumn 4, Issue 3, 2008, Pages 192-198

Stability of common analytes and urine particles stored at room temperature before automated analysis

Author keywords

Automated particle examination; Delayed testing; Dip strips readers; Storage; Urinalysis

Indexed keywords

ESTERASE; HEMOGLOBIN; NITRITE;

EID: 57049161536     PISSN: 1825859X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (18)
  • 2
    • 57049105342 scopus 로고    scopus 로고
    • Rabinovitch A, Sarewitz S, Woodcock S, Allinger D, Dynek D. Urinalysis and Collection, Transportation, and preservation of Urine Specimens; Approved Guideline-Second Edition. NCCLS Document GP16-AZ, Wayne, Pennsylvania, 2001.
    • Rabinovitch A, Sarewitz S, Woodcock S, Allinger D, Dynek D. Urinalysis and Collection, Transportation, and preservation of Urine Specimens; Approved Guideline-Second Edition. NCCLS Document GP16-AZ, Wayne, Pennsylvania, 2001.
  • 3
    • 0036275507 scopus 로고    scopus 로고
    • Preservation of urine for flow cytometry and visual microscopic testing
    • Kouri T, Vuotari L, Pohjavaara Laippala P. Preservation of urine for flow cytometry and visual microscopic testing. Clin Chem 2002; 48:900-5.
    • (2002) Clin Chem , vol.48 , pp. 900-905
    • Kouri, T.1    Vuotari, L.2    Pohjavaara Laippala, P.3
  • 4
    • 0033816984 scopus 로고    scopus 로고
    • Stability of common analytes in urine refrigerated for 24 h before automated analysis by test strips
    • Froom P, Bieganiec B, Ehrenrich Z, Barak M. Stability of common analytes in urine refrigerated for 24 h before automated analysis by test strips. Clin Chem 2000; 46:1384-6.
    • (2000) Clin Chem , vol.46 , pp. 1384-1386
    • Froom, P.1    Bieganiec, B.2    Ehrenrich, Z.3    Barak, M.4
  • 5
    • 0032966375 scopus 로고    scopus 로고
    • Del Rosario Rodriguez Moren M, Rodriguez Moreno I, Leon M, Boy M, Cowdry Agniueszka N. A new chemical preservative that permits analysis of urine sediment for light microscopic examination 12 h after emission. Nephron 1999; 82:65-71.
    • Del Rosario Rodriguez Moren M, Rodriguez Moreno I, Leon M, Boy M, Cowdry Agniueszka N. A new chemical preservative that permits analysis of urine sediment for light microscopic examination 12 h after emission. Nephron 1999; 82:65-71.
  • 6
    • 0032917983 scopus 로고    scopus 로고
    • The effect of specimens processing delay on borate urine preservation
    • Gillespie T, Fewster R, Masterson R. The effect of specimens processing delay on borate urine preservation. J Clin Pathol 1999; 52:95-8.
    • (1999) J Clin Pathol , vol.52 , pp. 95-98
    • Gillespie, T.1    Fewster, R.2    Masterson, R.3
  • 7
    • 0031982981 scopus 로고    scopus 로고
    • Evaluation of the Sysmex UF-100 automated urinalysis analyzer
    • Ben-Ezra J, Bork L, McPherson R. Evaluation of the Sysmex UF-100 automated urinalysis analyzer. Clin Chem 1998; 44:92-5.
    • (1998) Clin Chem , vol.44 , pp. 92-95
    • Ben-Ezra, J.1    Bork, L.2    McPherson, R.3
  • 8
    • 26844543578 scopus 로고    scopus 로고
    • Preliminary evaluation of the Iris IQ 200 automated urine analyser
    • Alves L, Ballester F, Camps J, Joven J. Preliminary evaluation of the Iris IQ 200 automated urine analyser. Clin Chem Lab Med 2005; 43:967-70.
    • (2005) Clin Chem Lab Med , vol.43 , pp. 967-970
    • Alves, L.1    Ballester, F.2    Camps, J.3    Joven, J.4
  • 9
    • 0036803126 scopus 로고    scopus 로고
    • Field evaluation of a second generation cytometer UF-100 in diagnosis of acute urinary tract infections in adult patients
    • Manoni F, Valverde S, Antico F, Salvadego M, Giacomini A, Gessoni G. Field evaluation of a second generation cytometer UF-100 in diagnosis of acute urinary tract infections in adult patients. Clin Lab Infect 2002; 8:662-8.
    • (2002) Clin Lab Infect , vol.8 , pp. 662-668
    • Manoni, F.1    Valverde, S.2    Antico, F.3    Salvadego, M.4    Giacomini, A.5    Gessoni, G.6
  • 11
    • 80051672729 scopus 로고    scopus 로고
    • Standardized counting of particles in the urine: A comparison between flow cytometry, cell chamber counting and traditional sediment analysis
    • Ottinger C, Regeniter A, Kochli H, Huber A. Standardized counting of particles in the urine: a comparison between flow cytometry, cell chamber counting and traditional sediment analysis. Schweiz Rundusch Med Prax 2004; 7:15-21.
    • (2004) Schweiz Rundusch Med Prax , vol.7 , pp. 15-21
    • Ottinger, C.1    Regeniter, A.2    Kochli, H.3    Huber, A.4
  • 12
    • 0035010759 scopus 로고    scopus 로고
    • Urine analysis performed by flow citometry: Reference range determination and comparison to morphological findings, dipstik chemistry and bacterial culture results - a multicentric study
    • Regeniter A, Haenni V, Risch L, Kochli H, Colombo J, Frei R, et al. Urine analysis performed by flow citometry: reference range determination and comparison to morphological findings, dipstik chemistry and bacterial culture results - a multicentric study. Clin Nephrol 2001; 55:384-92.
    • (2001) Clin Nephrol , vol.55 , pp. 384-392
    • Regeniter, A.1    Haenni, V.2    Risch, L.3    Kochli, H.4    Colombo, J.5    Frei, R.6
  • 13
    • 0036893335 scopus 로고    scopus 로고
    • Quantitative Evaluation of Urinalysis Test Strips
    • Penders J, Fiers T, Delanghe J. Quantitative Evaluation of Urinalysis Test Strips. Clin Chem 2002; 48:2236-41.
    • (2002) Clin Chem , vol.48 , pp. 2236-2241
    • Penders, J.1    Fiers, T.2    Delanghe, J.3
  • 14
    • 0032924912 scopus 로고    scopus 로고
    • Automated Flow Cytometry Compared with an Automated Dipstick Reader for Urinalysis
    • Langlois M, Delanghe J, Steyaert S, Everaert K, De Buyzere M. Automated Flow Cytometry Compared with an Automated Dipstick Reader for Urinalysis. Clin Chem 1999; 45:118-22.
    • (1999) Clin Chem , vol.45 , pp. 118-122
    • Langlois, M.1    Delanghe, J.2    Steyaert, S.3    Everaert, K.4    De Buyzere, M.5
  • 15
    • 33845487344 scopus 로고    scopus 로고
    • Comparison of three automated urinalysis systems-Siemens Clinitek Atlas, Roche Urisys 2400 and Arkray Aution Max for testing urine chemistry and detection of bacteriuria
    • Chien TI, Lu JY, Kao JT, Lee TF, Ho SY, Chang CY, et al. Comparison of three automated urinalysis systems-Siemens Clinitek Atlas, Roche Urisys 2400 and Arkray Aution Max for testing urine chemistry and detection of bacteriuria. Clin Chim Acta 2007; 377:98-102.
    • (2007) Clin Chim Acta , vol.377 , pp. 98-102
    • Chien, T.I.1    Lu, J.Y.2    Kao, J.T.3    Lee, T.F.4    Ho, S.Y.5    Chang, C.Y.6
  • 16
    • 0018758407 scopus 로고
    • Evaluation of preservative fluid for urine collected for culture
    • Lauer B, Reller B, Mirrett S. Evaluation of preservative fluid for urine collected for culture. J Clin Microbiol 1979; 10:42-5.
    • (1979) J Clin Microbiol , vol.10 , pp. 42-45
    • Lauer, B.1    Reller, B.2    Mirrett, S.3
  • 17
    • 0037380114 scopus 로고    scopus 로고
    • Quantitative urine particles analysis: Integrative approach for the optimal combination of automation with UF 100 and microscopic review with KOVa cell chamber
    • Ottinger C, Huber A. Quantitative urine particles analysis: integrative approach for the optimal combination of automation with UF 100 and microscopic review with KOVa cell chamber. Clin Chem 2004; 49:617-23.
    • (2004) Clin Chem , vol.49 , pp. 617-623
    • Ottinger, C.1    Huber, A.2
  • 18
    • 0016560851 scopus 로고
    • Quantification of casts in urine sediment
    • Burton J. Quantification of casts in urine sediment. Ann Intern Med 1975; 83:518-9.
    • (1975) Ann Intern Med , vol.83 , pp. 518-519
    • Burton, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.