메뉴 건너뛰기




Volumn 89, Issue 3, 2008, Pages 311-319

Detection of intrafractional tumour position error in radiotherapy utilizing cone beam computed tomography

Author keywords

Cone beam CT; Errors; Intrafractional; Radiotherapy

Indexed keywords

ABDOMINAL TUMOR; ADULT; AGED; ARTICLE; CANCER LOCALIZATION; CANCER RADIOTHERAPY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; HEAD AND NECK TUMOR; HUMAN; MAJOR CLINICAL STUDY; MALE; MEDICAL ERROR; PELVIS TUMOR; PRIORITY JOURNAL; RADIATION DOSE; THORAX TUMOR; X RAY;

EID: 57049151793     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2008.08.003     Document Type: Article
Times cited : (40)

References (51)
  • 1
    • 20644450346 scopus 로고    scopus 로고
    • Computed tomography guided management of interfractional patient variation
    • Yan D., Lockman D., Martinez A., et al. Computed tomography guided management of interfractional patient variation. Semin Radiat Oncol 15 (2005) 168-179
    • (2005) Semin Radiat Oncol , vol.15 , pp. 168-179
    • Yan, D.1    Lockman, D.2    Martinez, A.3
  • 2
    • 0035252342 scopus 로고    scopus 로고
    • Set-up verification using portal imaging; review of current clinical practice
    • Hurkmans C.W., Remeijer P., Lebesque J.V., et al. Set-up verification using portal imaging; review of current clinical practice. Radiother Oncol 58 (2001) 105-120
    • (2001) Radiother Oncol , vol.58 , pp. 105-120
    • Hurkmans, C.W.1    Remeijer, P.2    Lebesque, J.V.3
  • 3
    • 33748288037 scopus 로고    scopus 로고
    • Assessment of residual error in liver position using KV cone-beam computed tomography for liver cancer high-precision radiation therapy
    • Hawkins M.A., Brock K.K., Eccles C., et al. Assessment of residual error in liver position using KV cone-beam computed tomography for liver cancer high-precision radiation therapy. Int J Radiat Oncol Biol Phys 66 (2006) 610-619
    • (2006) Int J Radiat Oncol Biol Phys , vol.66 , pp. 610-619
    • Hawkins, M.A.1    Brock, K.K.2    Eccles, C.3
  • 4
    • 0029817312 scopus 로고    scopus 로고
    • Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing
    • Balter J.M., Ten Haken R.K., Lawrence T.S., et al. Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. Int J Radiat Oncol Biol Phys 36 (1996) 167-174
    • (1996) Int J Radiat Oncol Biol Phys , vol.36 , pp. 167-174
    • Balter, J.M.1    Ten Haken, R.K.2    Lawrence, T.S.3
  • 6
    • 0034237722 scopus 로고    scopus 로고
    • Dosimetric effects of patient displacement and collimator and gantry angle misalignment on intensity modulated radiation therapy
    • Xing L., Lin Z.X., Sarah S., et al. Dosimetric effects of patient displacement and collimator and gantry angle misalignment on intensity modulated radiation therapy. Radiother Oncol 56 (2000) 97-108
    • (2000) Radiother Oncol , vol.56 , pp. 97-108
    • Xing, L.1    Lin, Z.X.2    Sarah, S.3
  • 7
    • 0028811317 scopus 로고
    • Prostate motion during standard radiotherapy as assessed by fiducial markers
    • Crook J.M., Raymond Y., Salhani D., et al. Prostate motion during standard radiotherapy as assessed by fiducial markers. Radiother Oncol 37 (1995) 35-42
    • (1995) Radiother Oncol , vol.37 , pp. 35-42
    • Crook, J.M.1    Raymond, Y.2    Salhani, D.3
  • 8
    • 0035283698 scopus 로고    scopus 로고
    • Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate
    • Alasti H., Petric M.P., Catton C.N., et al. Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate. Int J Radiat Oncol Biol Phys 49 (2001) 869-884
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 869-884
    • Alasti, H.1    Petric, M.P.2    Catton, C.N.3
  • 9
    • 0034332698 scopus 로고    scopus 로고
    • Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame
    • Wulf J., Hadinger U., Oppitz U., Olshausen B., and Flentje M. Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame. Radiother Oncol 57 (2000) 225-236
    • (2000) Radiother Oncol , vol.57 , pp. 225-236
    • Wulf, J.1    Hadinger, U.2    Oppitz, U.3    Olshausen, B.4    Flentje, M.5
  • 10
    • 0037296427 scopus 로고    scopus 로고
    • Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver
    • Wulf J., Hadinger U., Oppitz U., Thiele W., and Flentje M. Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver. Radiother Oncol 66 (2003) 141-150
    • (2003) Radiother Oncol , vol.66 , pp. 141-150
    • Wulf, J.1    Hadinger, U.2    Oppitz, U.3    Thiele, W.4    Flentje, M.5
  • 11
    • 33745487474 scopus 로고    scopus 로고
    • Fiducial markers for MRI-based target volume definition and treatment verification
    • Visser A.G., van Lin E.N.J.T., Welmers A., et al. Fiducial markers for MRI-based target volume definition and treatment verification. Radiother Oncol 64 Suppl. 1 (2002) S41
    • (2002) Radiother Oncol , vol.64 , Issue.SUPPL. 1
    • Visser, A.G.1    van Lin, E.N.J.T.2    Welmers, A.3
  • 12
    • 0036569622 scopus 로고    scopus 로고
    • Measurements and clinical consequences of prostate motion during a radiotherapy fraction
    • Nederveen A.J., Van der Heide U.A., Dehnad H., et al. Measurements and clinical consequences of prostate motion during a radiotherapy fraction. Int J Radiat Oncol Biol Phys 53 (2002) 206-214
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 206-214
    • Nederveen, A.J.1    Van der Heide, U.A.2    Dehnad, H.3
  • 13
    • 0038372040 scopus 로고    scopus 로고
    • Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID
    • Aubin S., Beaulieu L., Pouliot S., et al. Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID. Med Phys 30 (2003) 1825-1832
    • (2003) Med Phys , vol.30 , pp. 1825-1832
    • Aubin, S.1    Beaulieu, L.2    Pouliot, S.3
  • 14
    • 33745501473 scopus 로고    scopus 로고
    • The use of fiducial (gold) markers for monitoring prostate movements during radiation therapy
    • Spitters-Post I., van der Vight L.P., van Lin E.N.J.T., and Visser A.G. The use of fiducial (gold) markers for monitoring prostate movements during radiation therapy. Radiother Oncol 64 Suppl. 1 (2002) S44
    • (2002) Radiother Oncol , vol.64 , Issue.SUPPL. 1
    • Spitters-Post, I.1    van der Vight, L.P.2    van Lin, E.N.J.T.3    Visser, A.G.4
  • 15
    • 30544448874 scopus 로고    scopus 로고
    • Intra-fraction patient motion in head/neck cancer patients undergoing intensity-modulated radiation therapy (abstract)
    • Lee N., Zhu N., Baker L., et al. Intra-fraction patient motion in head/neck cancer patients undergoing intensity-modulated radiation therapy (abstract). Int J Radiat Oncol Biol Phys 57 (2003) S409
    • (2003) Int J Radiat Oncol Biol Phys , vol.57
    • Lee, N.1    Zhu, N.2    Baker, L.3
  • 16
    • 1642266409 scopus 로고    scopus 로고
    • Evaluation of intra-fraction patient movement for CNS and head and neck IMRT
    • Kim S., Akpati H.C., Kielbasa J.E., et al. Evaluation of intra-fraction patient movement for CNS and head and neck IMRT. Med Phys 31 (2004) 500-506
    • (2004) Med Phys , vol.31 , pp. 500-506
    • Kim, S.1    Akpati, H.C.2    Kielbasa, J.E.3
  • 17
    • 9344238243 scopus 로고    scopus 로고
    • A methodology to determine margins by EPID measurements of patient setup variation and motion as applied to immobilization devices
    • Prisciandaro J.I., Frechette C.M., Herman M.G., Brown P.D., Garces Y.I., and Foote R.L. A methodology to determine margins by EPID measurements of patient setup variation and motion as applied to immobilization devices. Med Phys 31 (2004) 2978-2988
    • (2004) Med Phys , vol.31 , pp. 2978-2988
    • Prisciandaro, J.I.1    Frechette, C.M.2    Herman, M.G.3    Brown, P.D.4    Garces, Y.I.5    Foote, R.L.6
  • 18
    • 0028786274 scopus 로고
    • A precision cranial immobilization system for conformal stereotactic fractionated radiation therapy
    • Rosenthal S.J., Gall K.P., Jackson M., and Thornton Jr. A.F. A precision cranial immobilization system for conformal stereotactic fractionated radiation therapy. Int J Radiat Oncol Biol Phys 33 (1995) 1239-1245
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 1239-1245
    • Rosenthal, S.J.1    Gall, K.P.2    Jackson, M.3    Thornton Jr., A.F.4
  • 19
    • 0028123299 scopus 로고
    • Larynx motion associated with swallowing during radiation therapy
    • Hamlet S., Ezzell G., and Aref A. Larynx motion associated with swallowing during radiation therapy. Int J Radiat Oncol Biol Phys 28 (1994) 467-470
    • (1994) Int J Radiat Oncol Biol Phys , vol.28 , pp. 467-470
    • Hamlet, S.1    Ezzell, G.2    Aref, A.3
  • 20
    • 34447100119 scopus 로고    scopus 로고
    • Intra- and interfraction breathing variations during curative radiotherapy for lung cancer
    • Nøttrup T.J., Korreman S.S., Pedersen A.N., et al. Intra- and interfraction breathing variations during curative radiotherapy for lung cancer. Radiother Oncol 84 (2007) 40-48
    • (2007) Radiother Oncol , vol.84 , pp. 40-48
    • Nøttrup, T.J.1    Korreman, S.S.2    Pedersen, A.N.3
  • 21
    • 0035400715 scopus 로고    scopus 로고
    • The effect of breathing and set-up errors on the cumulative dose to a lung tumor
    • Engelsman M., Damen E.M.F., De Jaeger K., et al. The effect of breathing and set-up errors on the cumulative dose to a lung tumor. Radiother Oncol 60 (2001) 95-105
    • (2001) Radiother Oncol , vol.60 , pp. 95-105
    • Engelsman, M.1    Damen, E.M.F.2    De Jaeger, K.3
  • 22
    • 0344872657 scopus 로고    scopus 로고
    • Organ motion, set-up variation and treatment margins in radical radiotherapy of urinary bladder cancer
    • Muren L.P., Smaaland R., and Dahl O. Organ motion, set-up variation and treatment margins in radical radiotherapy of urinary bladder cancer. Radiother Oncol 69 (2003) 291-304
    • (2003) Radiother Oncol , vol.69 , pp. 291-304
    • Muren, L.P.1    Smaaland, R.2    Dahl, O.3
  • 23
    • 0036661305 scopus 로고    scopus 로고
    • Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report
    • Stroom J.C., and Heijmen B.J.M. Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report. Radiother Oncol 64 (2002) 75-83
    • (2002) Radiother Oncol , vol.64 , pp. 75-83
    • Stroom, J.C.1    Heijmen, B.J.M.2
  • 24
    • 34047145827 scopus 로고    scopus 로고
    • Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors
    • Guckenberger M., Meyer J., Wilbert J., et al. Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors. Radiother Oncol 83 (2007) 57-64
    • (2007) Radiother Oncol , vol.83 , pp. 57-64
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3
  • 25
    • 0033813993 scopus 로고    scopus 로고
    • How should breathing motion be combined with other errors when drawing margins around clinical target volumes?
    • Mckenzie A.L. How should breathing motion be combined with other errors when drawing margins around clinical target volumes?. Br J Radiol 73 (2000) 973-977
    • (2000) Br J Radiol , vol.73 , pp. 973-977
    • Mckenzie, A.L.1
  • 26
    • 0031870905 scopus 로고    scopus 로고
    • What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?
    • Ekberg L., Holmberg O., Wittgren L., Bjelkengren G., and Landberg T. What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?. Radiother Oncol 48 (1998) 71-77
    • (1998) Radiother Oncol , vol.48 , pp. 71-77
    • Ekberg, L.1    Holmberg, O.2    Wittgren, L.3    Bjelkengren, G.4    Landberg, T.5
  • 27
    • 0036804522 scopus 로고    scopus 로고
    • Measurement of intrafractional prostate motion using magnetic resonance imaging
    • Mah D., Freedman G., Milestone B., et al. Measurement of intrafractional prostate motion using magnetic resonance imaging. Int J Radiat Oncol Biol Phys 54 (2002) 568-575
    • (2002) Int J Radiat Oncol Biol Phys , vol.54 , pp. 568-575
    • Mah, D.1    Freedman, G.2    Milestone, B.3
  • 28
    • 0036603793 scopus 로고    scopus 로고
    • Intrafraction prostate motion during IMRT for prostate cancer
    • Huang E., Dong L., Chandra A., et al. Intrafraction prostate motion during IMRT for prostate cancer. Int J Radiat Oncol Biol Phys 53 (2002) 261-268
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 261-268
    • Huang, E.1    Dong, L.2    Chandra, A.3
  • 29
    • 0038415720 scopus 로고    scopus 로고
    • Experience of ultrasound-based daily prostate localization
    • Chandra A., Dong L., Huang E., et al. Experience of ultrasound-based daily prostate localization. Int J Radiat Oncol Biol Phys 56 (2003) 436-447
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 436-447
    • Chandra, A.1    Dong, L.2    Huang, E.3
  • 30
    • 0036223115 scopus 로고    scopus 로고
    • Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
    • Kitamura K., Shirato H., Shimizu S., et al. Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT). Radiother Oncol 62 (2002) 275-281
    • (2002) Radiother Oncol , vol.62 , pp. 275-281
    • Kitamura, K.1    Shirato, H.2    Shimizu, S.3
  • 31
    • 0034566036 scopus 로고    scopus 로고
    • Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers
    • Shimizu S., Shirato H., Kitamura K., et al. Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. Int J Radiat Oncol Biol Phys 48 (2000) 1591-1597
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 1591-1597
    • Shimizu, S.1    Shirato, H.2    Kitamura, K.3
  • 32
    • 30544448340 scopus 로고    scopus 로고
    • X-ray volumetric imaging in image-guided radiotherapy: the new standard in on-treatment imaging
    • McBain C.A., Henry A.M., Sykes J., et al. X-ray volumetric imaging in image-guided radiotherapy: the new standard in on-treatment imaging. Int J Radiat Oncol Biol Phys 64 (2006) 625-634
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 625-634
    • McBain, C.A.1    Henry, A.M.2    Sykes, J.3
  • 33
    • 38149111288 scopus 로고    scopus 로고
    • 3D in vivo dose verification of entire hypo-fractionated IMRT treatments using an EPID and cone-beam CT
    • McDermott L.N., Wendling M., Nijkamp J., et al. 3D in vivo dose verification of entire hypo-fractionated IMRT treatments using an EPID and cone-beam CT. Radiother Oncol 86 (2008) 35-42
    • (2008) Radiother Oncol , vol.86 , pp. 35-42
    • McDermott, L.N.1    Wendling, M.2    Nijkamp, J.3
  • 34
    • 35248819236 scopus 로고    scopus 로고
    • A study on adaptive IMRT treatment planning using kV cone-beam CT
    • Ding G.X., Duggan D.M., Coffey C.W., et al. A study on adaptive IMRT treatment planning using kV cone-beam CT. Radiother Oncol 85 1 (2007) 116-125
    • (2007) Radiother Oncol , vol.85 , Issue.1 , pp. 116-125
    • Ding, G.X.1    Duggan, D.M.2    Coffey, C.W.3
  • 35
    • 33644549665 scopus 로고    scopus 로고
    • Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue
    • Brock K.K., Dawson L.A., Sharpe M.B., et al. Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue. Int J Radiat Oncol Biol Phys 64 (2006) 1245-1254
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 1245-1254
    • Brock, K.K.1    Dawson, L.A.2    Sharpe, M.B.3
  • 37
    • 33744823315 scopus 로고    scopus 로고
    • Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy
    • Islam M.K., Purdie T.G., Norrlinger B.D., et al. Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy. Med Phys 33 (2006) 1573-1582
    • (2006) Med Phys , vol.33 , pp. 1573-1582
    • Islam, M.K.1    Purdie, T.G.2    Norrlinger, B.D.3
  • 38
    • 0030067570 scopus 로고    scopus 로고
    • A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs
    • Hristov D.H., and Fallone B.G. A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs. Med Phys 23 (1996) 75-84
    • (1996) Med Phys , vol.23 , pp. 75-84
    • Hristov, D.H.1    Fallone, B.G.2
  • 39
    • 27144511689 scopus 로고    scopus 로고
    • A feasibility study for image guided radiotherapy using low dose, high speed, cone beam X-ray volumetric imaging
    • Sykes J.R., Amer A., Czajka J., and Moore C.J. A feasibility study for image guided radiotherapy using low dose, high speed, cone beam X-ray volumetric imaging. Radiother Oncol 77 (2005) 45-52
    • (2005) Radiother Oncol , vol.77 , pp. 45-52
    • Sykes, J.R.1    Amer, A.2    Czajka, J.3    Moore, C.J.4
  • 40
    • 0842306308 scopus 로고    scopus 로고
    • Errors and margins in radiotherapy
    • van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol 14 (2004) 52-64
    • (2004) Semin Radiat Oncol , vol.14 , pp. 52-64
    • van Herk, M.1
  • 41
    • 57049179691 scopus 로고    scopus 로고
    • International Commission on Radiation Units and Measurements. ICRU Report 62. Prescribing, recording, and reporting photon beam therapy (Supplement to ICRU Report 50). Bethesda, MD: ICRU; 1999.
    • International Commission on Radiation Units and Measurements. ICRU Report 62. Prescribing, recording, and reporting photon beam therapy (Supplement to ICRU Report 50). Bethesda, MD: ICRU; 1999.
  • 42
    • 0021851642 scopus 로고
    • Calculation of the uncertainty in the dose delivered during radiation therapy
    • Goitein M. Calculation of the uncertainty in the dose delivered during radiation therapy. Med Phys 12 (1985) 608-612
    • (1985) Med Phys , vol.12 , pp. 608-612
    • Goitein, M.1
  • 43
    • 33645989447 scopus 로고    scopus 로고
    • Analysis of interfractional set-up errors and intrafractional organ motions during IMRT for head and neck tumors to define an appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins
    • Suzuki M., Nishimura Y., Nakamatsu K., et al. Analysis of interfractional set-up errors and intrafractional organ motions during IMRT for head and neck tumors to define an appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins. Radiother Oncol 78 (2006) 283-290
    • (2006) Radiother Oncol , vol.78 , pp. 283-290
    • Suzuki, M.1    Nishimura, Y.2    Nakamatsu, K.3
  • 45
    • 26644455690 scopus 로고    scopus 로고
    • Stereotactic radiotherapy for lung and liver tumors using a body cast system: setup accuracy and preliminary clinical outcome
    • Shioyama Y., Nakamura K., Anai S., et al. Stereotactic radiotherapy for lung and liver tumors using a body cast system: setup accuracy and preliminary clinical outcome. Radiat Med 23 (2005) 407-413
    • (2005) Radiat Med , vol.23 , pp. 407-413
    • Shioyama, Y.1    Nakamura, K.2    Anai, S.3
  • 46
    • 33748873299 scopus 로고    scopus 로고
    • IGRT of prostate cancer; is the margin reduction gained from daily IG time-dependent?
    • Enmark M., Korreman S., and Nyströ M.H. IGRT of prostate cancer; is the margin reduction gained from daily IG time-dependent?. Acta Oncol 45 (2006) 907-914
    • (2006) Acta Oncol , vol.45 , pp. 907-914
    • Enmark, M.1    Korreman, S.2    Nyströ, M.H.3
  • 47
    • 21244498471 scopus 로고    scopus 로고
    • Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients
    • Letourneau D., Martinez A., Lockman D., et al. Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients. Int J Radiat Oncol Biol Phys 62 (2005) 1239-1246
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 1239-1246
    • Letourneau, D.1    Martinez, A.2    Lockman, D.3
  • 48
    • 46549089223 scopus 로고    scopus 로고
    • Application of active breathing control in 3-dimensional conformal radiation therapy for hepatocellular carcinoma: the feasibility and benefit
    • Zhao J.D., Xu Z.Y., Zhu J., et al. Application of active breathing control in 3-dimensional conformal radiation therapy for hepatocellular carcinoma: the feasibility and benefit. Radiother Oncol 87 (2008) 439-444
    • (2008) Radiother Oncol , vol.87 , pp. 439-444
    • Zhao, J.D.1    Xu, Z.Y.2    Zhu, J.3
  • 49
    • 34548290360 scopus 로고    scopus 로고
    • Imaging doses from the Elekta synergy X-ray cone beam CT system
    • Amer A., Marchant T., Sykes J., et al. Imaging doses from the Elekta synergy X-ray cone beam CT system. Br J Radiol 80 (2007) 476-482
    • (2007) Br J Radiol , vol.80 , pp. 476-482
    • Amer, A.1    Marchant, T.2    Sykes, J.3
  • 50
    • 40249113450 scopus 로고    scopus 로고
    • Is daily CT image guidance necessary for nasal cavity and nasopharyngeal radiotherapy: an investigation based on helical tomotherapy
    • Sheng K., Chow M.C., Hunter G., Larner J.M., and Read P.W. Is daily CT image guidance necessary for nasal cavity and nasopharyngeal radiotherapy: an investigation based on helical tomotherapy. J Appl Clin Med Phys 9 (2008) 36-46
    • (2008) J Appl Clin Med Phys , vol.9 , pp. 36-46
    • Sheng, K.1    Chow, M.C.2    Hunter, G.3    Larner, J.M.4    Read, P.W.5
  • 51
    • 0030422050 scopus 로고    scopus 로고
    • Thévenaz P, Unser M. A pyramid approach to sub-pixel image fusion based on mutual information. In: Proceedings of the 3rd IEEE international conference on image processing, vol. I. Lausanne, Switzerland: IEEE Image Processing Society; 1996. p. 265-268.
    • Thévenaz P, Unser M. A pyramid approach to sub-pixel image fusion based on mutual information. In: Proceedings of the 3rd IEEE international conference on image processing, vol. I. Lausanne, Switzerland: IEEE Image Processing Society; 1996. p. 265-268.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.