메뉴 건너뛰기




Volumn 43, Issue 9-10, 2008, Pages 1498-1505

A comparison of the measured responses of a tissue-equivalent proportional counter to high energy heavy (HZE) particles and those simulated using the Geant4 Monte Carlo code

Author keywords

Geant4; Heavy ions; HZE; Microdosimetry; TEPC; Tissue equivalent proportional counter

Indexed keywords

ALUMINA; ATOMS; COUNTING CIRCUITS; ELECTROLYSIS; ELECTRONS; HEAVY IONS; HELIUM; ION BEAMS; IONS; MONTE CARLO METHODS; OPTICAL RESOLVING POWER; PROPANE; PROPORTIONAL COUNTERS; SPHERES; TISSUE;

EID: 56949102737     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2008.09.003     Document Type: Article
Times cited : (12)

References (24)
  • 3
    • 0036149186 scopus 로고    scopus 로고
    • Shuttle radiation dose measurements in the international space station orbits
    • Badhwar G.D. Shuttle radiation dose measurements in the international space station orbits. Radiat. Res. 157 (2002) 69-75
    • (2002) Radiat. Res. , vol.157 , pp. 69-75
    • Badhwar, G.D.1
  • 4
    • 0027965233 scopus 로고
    • Measurements on the shuttle of the LET spectra of galactic cosmic radiation and comparison with the radiation transport model
    • Badhwar G.D., Cucinotta F.A., Braby L.A., and Konradi A. Measurements on the shuttle of the LET spectra of galactic cosmic radiation and comparison with the radiation transport model. Radiat. Res. 139 (1994) 344-351
    • (1994) Radiat. Res. , vol.139 , pp. 344-351
    • Badhwar, G.D.1    Cucinotta, F.A.2    Braby, L.A.3    Konradi, A.4
  • 6
    • 33846284857 scopus 로고    scopus 로고
    • Microdosimetric GEANT4 and FLUKA Monte Carlo simulations and measurements of heavy ion irradiation of silicon and tissue
    • Beck P., Wind M., Rollett S., Latocha M., Bock F., Bock H., and Uchihori Y. Microdosimetric GEANT4 and FLUKA Monte Carlo simulations and measurements of heavy ion irradiation of silicon and tissue. IEEE Trans. Nucl. Sci. 53 (2006) 3701-3706
    • (2006) IEEE Trans. Nucl. Sci. , vol.53 , pp. 3701-3706
    • Beck, P.1    Wind, M.2    Rollett, S.3    Latocha, M.4    Bock, F.5    Bock, H.6    Uchihori, Y.7
  • 7
    • 9244221609 scopus 로고    scopus 로고
    • Comparisons of LET distributions for protons with energies between 50 and 200 MeV determined using a spherical tissue-equivalent proportional counter (TEPC) and a position-sensitive silicon spectrometer (RRMD-III)
    • Borak T.B., Doke T., Fuse T., Guetersloh S., Heilbronn L., Hara K., Moyers M., Suzuki S., Taddei P., Terasawa K., and Zeitlin C.J. Comparisons of LET distributions for protons with energies between 50 and 200 MeV determined using a spherical tissue-equivalent proportional counter (TEPC) and a position-sensitive silicon spectrometer (RRMD-III). Radiat. Res. 162 (2004) 687-692
    • (2004) Radiat. Res. , vol.162 , pp. 687-692
    • Borak, T.B.1    Doke, T.2    Fuse, T.3    Guetersloh, S.4    Heilbronn, L.5    Hara, K.6    Moyers, M.7    Suzuki, S.8    Taddei, P.9    Terasawa, K.10    Zeitlin, C.J.11
  • 8
    • 0015840052 scopus 로고
    • Radial cutoff LET and radial cutoff dose calculations for heavy charged particles in water
    • Chatterjee A., Maccabee H.D., and Tobias C.A. Radial cutoff LET and radial cutoff dose calculations for heavy charged particles in water. Radiat. Res. 54 (1973) 479-494
    • (1973) Radiat. Res. , vol.54 , pp. 479-494
    • Chatterjee, A.1    Maccabee, H.D.2    Tobias, C.A.3
  • 9
    • 0017167303 scopus 로고
    • Microdosimetric structure of heavy ion tracks in tissue
    • Chatterjee A., and Schaefer H.J. Microdosimetric structure of heavy ion tracks in tissue. Radiat. Environ. Biophys. 13 (1976) 215-227
    • (1976) Radiat. Environ. Biophys. , vol.13 , pp. 215-227
    • Chatterjee, A.1    Schaefer, H.J.2
  • 12
    • 0034876337 scopus 로고    scopus 로고
    • Comparisons of LET distributions measured in low-earth orbit using tissue-equivalent proportional counters and the position-sensitive silicon-detector telescope (RRMD-III)
    • Doke T., Hayashi T., and Borak T.B. Comparisons of LET distributions measured in low-earth orbit using tissue-equivalent proportional counters and the position-sensitive silicon-detector telescope (RRMD-III). Radiat. Res. 156 (2001) 310-316
    • (2001) Radiat. Res. , vol.156 , pp. 310-316
    • Doke, T.1    Hayashi, T.2    Borak, T.B.3
  • 14
    • 0346734249 scopus 로고    scopus 로고
    • The response of a spherical tissue-equivalent proportional counter to different ions having similar linear energy transfer
    • Guetersloh S.B., Borak T.B., Taddei P.J., Zeitlin C., Heilbronn L., Miller J., Murakami T., and Iwata Y. The response of a spherical tissue-equivalent proportional counter to different ions having similar linear energy transfer. Radiat. Res. 161 (2004) 64-71
    • (2004) Radiat. Res. , vol.161 , pp. 64-71
    • Guetersloh, S.B.1    Borak, T.B.2    Taddei, P.J.3    Zeitlin, C.4    Heilbronn, L.5    Miller, J.6    Murakami, T.7    Iwata, Y.8
  • 15
    • 56949105137 scopus 로고    scopus 로고
    • Guetersloh, S.G., 2003. Response of a tissue equivalent proportional counter to different ions having a similar linear energy transfer. Department of Environmental and Radiological Health Sciences, PhD. Colorado State University, Fort Collins, CO, 156 pp.
    • Guetersloh, S.G., 2003. Response of a tissue equivalent proportional counter to different ions having a similar linear energy transfer. Department of Environmental and Radiological Health Sciences, PhD. Colorado State University, Fort Collins, CO, 156 pp.
  • 16
    • 10744227503 scopus 로고    scopus 로고
    • Simulation and analysis for astroparticle experiments
    • Howard A.S., and Araujo H. Simulation and analysis for astroparticle experiments. Nucl. Phys. B-Proc. Sup. 125 (2003) 320-326
    • (2003) Nucl. Phys. B-Proc. Sup. , vol.125 , pp. 320-326
    • Howard, A.S.1    Araujo, H.2
  • 17
    • 0036211373 scopus 로고    scopus 로고
    • The response of tissue-equivalent proportional counters to heavy ions
    • Nikjoo H., Khvostunov I.K., and Cucinotta F.A. The response of tissue-equivalent proportional counters to heavy ions. Radiat. Res. 157 (2002) 435-445
    • (2002) Radiat. Res. , vol.157 , pp. 435-445
    • Nikjoo, H.1    Khvostunov, I.K.2    Cucinotta, F.A.3
  • 18
    • 0031922150 scopus 로고    scopus 로고
    • Wall effects observed in tissue-equivalent proportional counters from 1.05 GeV/nucleon iron-56 particles
    • Rademacher S.E., Borak T.B., Zeitlin C., Heilbronn L., and Miller J. Wall effects observed in tissue-equivalent proportional counters from 1.05 GeV/nucleon iron-56 particles. Radiat. Res. 149 (1998) 387-395
    • (1998) Radiat. Res. , vol.149 , pp. 387-395
    • Rademacher, S.E.1    Borak, T.B.2    Zeitlin, C.3    Heilbronn, L.4    Miller, J.5
  • 19
    • 0001427396 scopus 로고
    • A device for the measurement of dose as a function of specific ionization
    • Rossi H.H., and Rosenzweig W. A device for the measurement of dose as a function of specific ionization. Radiology 64 (1955) 404-411
    • (1955) Radiology , vol.64 , pp. 404-411
    • Rossi, H.H.1    Rosenzweig, W.2
  • 20
    • 56949087317 scopus 로고    scopus 로고
    • Taddei, P.J., 2005. The response of a spherical tissue-equivalent proportional counter to different heavy ions with similar velocities. Department of Environmental and Radiological Health Sciences, PhD. Colorado State University, Fort Collins, CO, 171 pp.
    • Taddei, P.J., 2005. The response of a spherical tissue-equivalent proportional counter to different heavy ions with similar velocities. Department of Environmental and Radiological Health Sciences, PhD. Colorado State University, Fort Collins, CO, 171 pp.
  • 22
    • 56949101934 scopus 로고
    • Instrumentation for radiation measurements in space
    • Schimmerling W., and Curtis S.B. (Eds), Lawrence Berkeley National Laboratory Report LBL-8581
    • Wefel J.P. Instrumentation for radiation measurements in space. In: Schimmerling W., and Curtis S.B. (Eds). Proceedings of the Workshop on the Radiation Environment of the Satellite Power System (1978), Lawrence Berkeley National Laboratory Report LBL-8581
    • (1978) Proceedings of the Workshop on the Radiation Environment of the Satellite Power System
    • Wefel, J.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.