메뉴 건너뛰기




Volumn 131, Issue 3, 2008, Pages 399-403

Comparison of radiation dose to patient and staff for two interventional cardiology units: A phantom study

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; CINEANGIOCARDIOGRAPHY; CONTROLLED STUDY; DOSIMETRY; FLUOROSCOPY; HUMAN; IMAGE INTENSIFIER; INTERMETHOD COMPARISON; INTERVENTIONAL CARDIOVASCULAR PROCEDURE; OCCUPATIONAL EXPOSURE; PATIENT; PHANTOM; RADIATION EXPOSURE; RADIATION MEASUREMENT; RADIATION SCATTERING; RADIATION SHIELD; RADIOLOGICAL TECHNOLOGIST;

EID: 56849114611     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncn188     Document Type: Article
Times cited : (15)

References (14)
  • 1
    • 0030983107 scopus 로고    scopus 로고
    • Radiation exposure to patients and operators during diagnostic catheterization and coronary angioplasty
    • Zorzetto, M., Bernardi, G., Morocutti, G. Fontanelli, A. Radiation exposure to patients and operators during diagnostic catheterization and coronary angioplasty. Cathet. Cardiovasc. Diagn 40, 348-351 (1997).
    • (1997) Cathet. Cardiovasc. Diagn , vol.40 , pp. 348-351
    • Zorzetto, M.1    Bernardi, G.2    Morocutti, G.3    Fontanelli, A.4
  • 2
    • 33748974414 scopus 로고    scopus 로고
    • Leukemia mortality among radiation-exposed workers
    • Schubauer-Berigan, M. K. Wenzl, T. B. Leukemia mortality among radiation-exposed workers. Occup. Med. 16, 271-287 (2001).
    • (2001) Occup. Med , vol.16 , pp. 271-287
    • Schubauer-Berigan, M.K.1    Wenzl, T.B.2
  • 3
    • 0034920719 scopus 로고    scopus 로고
    • 100 years of observation on British radiologists: Mortality from cancer and other causes 1897-1997
    • Berrington, A., Darby, S. C., Weiss, H. A. Doll, R. 100 years of observation on British radiologists: Mortality from cancer and other causes 1897-1997. Br. J. Radiol. 74, 507-519 (2001).
    • (2001) Br. J. Radiol , vol.74 , pp. 507-519
    • Berrington, A.1    Darby, S.C.2    Weiss, H.A.3    Doll, R.4
  • 4
    • 0033781843 scopus 로고    scopus 로고
    • Influence of radiographic technique and equipment on absorbed ovarian dose associated with uterine artery embolization
    • Nikolic, B., Abbara, S., Levy, E., Imaoka, I., Lundsten, M. L., Jha, R. C. Spies, J. B. Influence of radiographic technique and equipment on absorbed ovarian dose associated with uterine artery embolization. J. Vasc. Interv. Radiol. 11, 1173-1178 (2000).
    • (2000) J. Vasc. Interv. Radiol , vol.11 , pp. 1173-1178
    • Nikolic, B.1    Abbara, S.2    Levy, E.3    Imaoka, I.4    Lundsten, M.L.5    Jha, R.C.6    Spies, J.B.7
  • 6
    • 34250343348 scopus 로고    scopus 로고
    • Do flat detector cardiac X-ray systems convey advantages over image-intensifier-based systems? Study comparing X-ray dose and image quality
    • Davies, A. G., Cowen, A. R., Kengyelics, S. M., Moore, J. Sivananthan, M. U. Do flat detector cardiac X-ray systems convey advantages over image-intensifier-based systems? Study comparing X-ray dose and image quality. Eur. Radiol. 17, 1787-1794 (2007).
    • (2007) Eur. Radiol , vol.17 , pp. 1787-1794
    • Davies, A.G.1    Cowen, A.R.2    Kengyelics, S.M.3    Moore, J.4    Sivananthan, M.U.5
  • 7
    • 0029124010 scopus 로고
    • The impact of digital imaging on patient doses during barium studies
    • Broadhead, D. A., Chapple, C. L. Faulkner, K. The impact of digital imaging on patient doses during barium studies. Br. J. Radiol. 68 992-996 (1995).
    • (1995) Br. J. Radiol , vol.68 , pp. 992-996
    • Broadhead, D.A.1    Chapple, C.L.2    Faulkner, K.3
  • 8
    • 1842375629 scopus 로고    scopus 로고
    • Ruiz-Cruces, R., Pérez-Martínez, M.,Martín-Palanca, A., Flores, A., Cristófol, J.,Marti'nez-Morillo, M., Díez de los Ríos, A. Patient dose in radiologically guided interventional vascular procedures: Conventional versus digital systems. Radiology 205, 385-393 (1997).
    • Ruiz-Cruces, R., Pérez-Martínez, M.,Martín-Palanca, A., Flores, A., Cristófol, J.,Marti'nez-Morillo, M., Díez de los Ríos, A. Patient dose in radiologically guided interventional vascular procedures: Conventional versus digital systems. Radiology 205, 385-393 (1997).
  • 9
    • 0003959446 scopus 로고    scopus 로고
    • Medical electrical equipment -part 2-43: Particular requirements for the safety of x-ray equipment for interventional procedures
    • International Electrotechnical Commission. Report 60601:, 60601-2-43 Geneva, Switzerland: IEC
    • International Electrotechnical Commission. Report 60601: Medical electrical equipment -part 2-43: Particular requirements for the safety of x-ray equipment for interventional procedures. 60601-2-43 (Geneva, Switzerland: IEC), (2000).
    • (2000)
  • 10
    • 56849088555 scopus 로고    scopus 로고
    • Radiation protection of angiographers in interventional radiology
    • Iida, H., Chabatake, M., Shimizu, M. Tamura, S. Radiation protection of angiographers in interventional radiology. Jpn J. Radiol. Technol. 57(12), 1548-1555 (2001).
    • (2001) Jpn J. Radiol. Technol , vol.57 , Issue.12 , pp. 1548-1555
    • Iida, H.1    Chabatake, M.2    Shimizu, M.3    Tamura, S.4
  • 11
    • 33745700268 scopus 로고    scopus 로고
    • Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology
    • Vano, E., Gonzalez, L., Fernandez, J. M., Prieto, C. Guibelalde, E. Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology. Radiat. Prot. Dosim. 118(3), 325-330 (2006).
    • (2006) Radiat. Prot. Dosim , vol.118 , Issue.3 , pp. 325-330
    • Vano, E.1    Gonzalez, L.2    Fernandez, J.M.3    Prieto, C.4    Guibelalde, E.5
  • 12
    • 33748079155 scopus 로고    scopus 로고
    • Radiation exposure to the primary operator during endovascular surgical neuroradiology procedures
    • Layton, K. F., Kallmes, D. F., Cloft, H. J., Schueler, B. A. Sturchio, G. M. Radiation exposure to the primary operator during endovascular surgical neuroradiology procedures. Am. J. Neuroradiol. 27, 742-743 (2006).
    • (2006) Am. J. Neuroradiol , vol.27 , pp. 742-743
    • Layton, K.F.1    Kallmes, D.F.2    Cloft, H.J.3    Schueler, B.A.4    Sturchio, G.M.5
  • 13
  • 14
    • 7944234005 scopus 로고    scopus 로고
    • Chida, K., Saito, H., Zuguchi, M., Shirotori, K., Kumagai, S., Nakayama, H., Matsubara, K. Kohzuki, M. Does digital acquisition reduce patients' skin dose in cardiac interventional procedures: An experimental study. AJR Am. J. 183, 1111-1114 (2004).
    • Chida, K., Saito, H., Zuguchi, M., Shirotori, K., Kumagai, S., Nakayama, H., Matsubara, K. Kohzuki, M. Does digital acquisition reduce patients' skin dose in cardiac interventional procedures: An experimental study. AJR Am. J. 183, 1111-1114 (2004).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.