메뉴 건너뛰기




Volumn 16, Issue 12, 2008, Pages 1080-1086

Comparison of the bioabsorbable and metal screw fixation after ACL reconstruction with a hamstring autograft in MRI and clinical outcome: A prospective randomized study

Author keywords

Anterior cruciate ligament reconstruction; Bioabsorbable screw; Clinical outcome; Hamstring graft; MRI; Prospective; Tunnel enlargement; Tunnel widening

Indexed keywords

ADOLESCENT; ADULT; ANTERIOR CRUCIATE LIGAMENT; ARTHROSCOPY; ARTICLE; AUTOTRANSPLANTATION; BIODEGRADABLE IMPLANT; BONE SCREW; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; FEMUR; HUMAN; INJURY; KNEE; MALE; METHODOLOGY; MIDDLE AGED; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; RANDOMIZED CONTROLLED TRIAL; TIBIA;

EID: 56749185610     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-008-0593-z     Document Type: Article
Times cited : (76)

References (19)
  • 1
    • 33746796725 scopus 로고    scopus 로고
    • Long-term absorption of poly-l-lactic acid interference screws
    • A Barber D Dockery 2006 Long-term absorption of poly-l-lactic acid interference screws Arthroscopy 22 820 826
    • (2006) Arthroscopy , vol.22 , pp. 820-826
    • Barber, A.1    Dockery, D.2
  • 2
    • 0038051473 scopus 로고    scopus 로고
    • Adverse tissue reactions to bioabsorbable fixation devices
    • O Böstman H Pihlajamäki 2000 Adverse tissue reactions to bioabsorbable fixation devices Clin Orthop Relat Res 371 216 227
    • (2000) Clin Orthop Relat Res , vol.371 , pp. 216-227
    • Böstman, O.1    Pihlajamäki, H.2
  • 4
    • 0037342540 scopus 로고    scopus 로고
    • Evaluation of tibial bone tunnel enlargement using MRI scan cross-sectional area measurement after autologous hamstring tendon ACL replacement
    • P Fules R Madhav R Goddard A Newman-Sanders M Mowbray 2003 Evaluation of tibial bone tunnel enlargement using MRI scan cross-sectional area measurement after autologous hamstring tendon ACL replacement Knee 10 87 91
    • (2003) Knee , vol.10 , pp. 87-91
    • Fules, P.1    Madhav, R.2    Goddard, R.3    Newman-Sanders, A.4    Mowbray, M.5
  • 6
    • 0032245391 scopus 로고    scopus 로고
    • Bone tunnel enlargement after anterior cruciate ligament reconstruction: Fact or fiction?
    • J Höher HD Möller FH Fu 1998 Bone tunnel enlargement after anterior cruciate ligament reconstruction: fact or fiction? Knee Surg Sports Traumatol Arthrosc 6 231 240
    • (1998) Knee Surg Sports Traumatol Arthrosc , vol.6 , pp. 231-240
    • Höher, J.1    Möller, H.D.2    Fu, F.H.3
  • 8
    • 0032827120 scopus 로고    scopus 로고
    • Serial magnetic resonance imaging evaluation of operative site after fixation of patellar tendon graft with bioabsorbable interference screws in anterior cruciate ligament reconstruction
    • G Lajtai I Noszian K Humer F Unger G Aitzetmüller E Orthner 1999 Serial magnetic resonance imaging evaluation of operative site after fixation of patellar tendon graft with bioabsorbable interference screws in anterior cruciate ligament reconstruction Arthroscopy 15 709 718
    • (1999) Arthroscopy , vol.15 , pp. 709-718
    • Lajtai, G.1    Noszian, I.2    Humer, K.3    Unger, F.4    Aitzetmüller, G.5    Orthner, E.6
  • 9
    • 0035413031 scopus 로고    scopus 로고
    • Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction: 5-year follow-up
    • G Lajtai G Schmiedhuber F Unger G Aitzetmüller M Klein I Noszian E Orthner 2001 Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction: 5-year follow-up Arthroscopy 17 597 602
    • (2001) Arthroscopy , vol.17 , pp. 597-602
    • Lajtai, G.1    Schmiedhuber, G.2    Unger, F.3    Aitzetmüller, G.4    Klein, M.5    Noszian, I.6    Orthner, E.7
  • 10
    • 33748666008 scopus 로고    scopus 로고
    • Biodegradable and metallic interference screws in anterior cruciate ligament reconstruction surgery using hamstring tendon grafts. Prospective randomized study of radiographic results and clinical outcome
    • G Laxdal J Kartus B Eriksson E Faxén N Sernert J Karlsson 2006 Biodegradable and metallic interference screws in anterior cruciate ligament reconstruction surgery using hamstring tendon grafts. Prospective randomized study of radiographic results and clinical outcome Am J Sports Med 34 1574 1580
    • (2006) Am J Sports Med , vol.34 , pp. 1574-1580
    • Laxdal, G.1    Kartus, J.2    Eriksson, B.3    Faxén, E.4    Sernert, N.5    Karlsson, J.6
  • 11
    • 0020309029 scopus 로고
    • Evaluation of knee ligament surgery results with special emphasis on use of scoring scale
    • J Lysholm J Gillquist 1982 Evaluation of knee ligament surgery results with special emphasis on use of scoring scale Am J Sports Med 10 150 154
    • (1982) Am J Sports Med , vol.10 , pp. 150-154
    • Lysholm, J.1    Gillquist, J.2
  • 12
    • 1242343973 scopus 로고    scopus 로고
    • Hamstring anterior cruciate ligament reconstruction: A comparison of bioabsorbable interference screw and endobutton-post fixation
    • CB Ma K Francis J Towers J Irrgang FH Fu CH Harner 2004 Hamstring anterior cruciate ligament reconstruction: a comparison of bioabsorbable interference screw and endobutton-post fixation Arthroscopy 20 122 128
    • (2004) Arthroscopy , vol.20 , pp. 122-128
    • Ma, C.B.1    Francis, K.2    Towers, J.3    Irrgang, J.4    Fu, F.H.5    Harner, C.H.6
  • 13
    • 33847095121 scopus 로고    scopus 로고
    • A prospective randomized study of anterior cruciate ligament reconstruction. A comparison of patellar tendon and quadruple-strand semitendinosus/gracilis tendons fixed with bioabsorbable interference screws
    • G Maletis S Cameron J Tengan R Burchette 2007 A prospective randomized study of anterior cruciate ligament reconstruction. A comparison of patellar tendon and quadruple-strand semitendinosus/gracilis tendons fixed with bioabsorbable interference screws Am J Sports Med 35 384 394
    • (2007) Am J Sports Med , vol.35 , pp. 384-394
    • Maletis, G.1    Cameron, S.2    Tengan, J.3    Burchette, R.4
  • 14
    • 0029681641 scopus 로고    scopus 로고
    • Tibial tunnel enlargement after anterior cruciate ligament reconstruction by autogenous bone-patellar tendon-bone graft
    • M Peyrache P Djian P Christel J Witvoet 1996 Tibial tunnel enlargement after anterior cruciate ligament reconstruction by autogenous bone-patellar tendon-bone graft Knee Surg Sports Traumatol Arthrosc 4 2 8
    • (1996) Knee Surg Sports Traumatol Arthrosc , vol.4 , pp. 2-8
    • Peyrache, M.1    Djian, P.2    Christel, P.3    Witvoet, J.4
  • 15
    • 0036329268 scopus 로고    scopus 로고
    • A five-year comparison of patellar tendon versus four-strand hamstring tendon autograft for arthroscopic reconstruction of the anterior cruciate ligament
    • LA Pinczewski DJ Deehan LJ Salmon VJ Russell A Clingeleffer 2002 A five-year comparison of patellar tendon versus four-strand hamstring tendon autograft for arthroscopic reconstruction of the anterior cruciate ligament Am J Sports Med 30 523 536
    • (2002) Am J Sports Med , vol.30 , pp. 523-536
    • Pinczewski, L.A.1    Deehan, D.J.2    Salmon, L.J.3    Russell, V.J.4    Clingeleffer, A.5
  • 16
    • 34250783880 scopus 로고    scopus 로고
    • A 10-year comparison of anterior cruciate ligament reconstructions with hamstring tendon and patellar tendon autograft: A controlled, prospective trial
    • L Pinczweski J Lyman L Salmon V Russell J Roe J Linklater 2007 A 10-year comparison of anterior cruciate ligament reconstructions with hamstring tendon and patellar tendon autograft: a controlled, prospective trial Am J Sports Med 35 564 574
    • (2007) Am J Sports Med , vol.35 , pp. 564-574
    • Pinczweski, L.1    Lyman, J.2    Salmon, L.3    Russell, V.4    Roe, J.5    Linklater, J.6
  • 17
    • 33644870933 scopus 로고    scopus 로고
    • Reduced bone tunnel enlargement post hamstring ACL reconstruction with poly-l-lactic acid/hydroxyapatite bioabsorbable screws
    • J Robinson C Huber P Jaraj P Colombet M Allard P Meyer 2006 Reduced bone tunnel enlargement post hamstring ACL reconstruction with poly-l-lactic acid/hydroxyapatite bioabsorbable screws Knee 13 127 131
    • (2006) Knee , vol.13 , pp. 127-131
    • Robinson, J.1    Huber, C.2    Jaraj, P.3    Colombet, P.4    Allard, M.5    Meyer, P.6
  • 18
    • 0036656563 scopus 로고    scopus 로고
    • Fluid collections in the osseous tunnel during the first year after anterior cruciate ligament repair using an autologous hamstring graft: Natural history and clinical correlation
    • TG Sanders MA Tall JP Mulloy HT Leis 2002 Fluid collections in the osseous tunnel during the first year after anterior cruciate ligament repair using an autologous hamstring graft: natural history and clinical correlation J Comput Assist Tomogr 26 617 621
    • (2002) J Comput Assist Tomogr , vol.26 , pp. 617-621
    • Sanders, T.G.1    Tall, M.A.2    Mulloy, J.P.3    Leis, H.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.