Volumn 35, Issue 12, 2008, Pages 5898-5909

A new weighting function to achieve high temporal resolution in circular cone-beam CT with shifted detectors

Author keywords

Cone beam CT (CBCT); Dynamic CT; Image quality; Micro CT

Indexed keywords

IMAGE QUALITY; X RAY DETECTORS;

EID: 56749183976     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3013700     Document Type: Article
Times cited : (17)

References (15)
  • 1
    • 0018701843 scopus 로고
    • Processing of incomplete measurement data in computed tomography
    • R. M. Lewitt, " Processing of incomplete measurement data in computed tomography.," Med. Phys. 6 (5), 412-417 (1979).
    • (1979) Med. Phys. , vol.6 , Issue.5 , pp. 412-417
    • Lewitt, R.M.1
  • 2
    • 0029040704 scopus 로고
    • Truncation artifact reduction in transmission CT for improved SPECT attenuation compensation
    • D. J. Kadrmas, R. J. Jaszczak, J. W. McCormick, R. E. Colemen, and C. B. Lim, " Truncation artifact reduction in transmission CT for improved SPECT attenuation compensation.," Phys. Med. Biol. 40, 1085-1104 (1995).
    • (1995) Phys. Med. Biol. , vol.40 , pp. 1085-1104
    • Kadrmas, D.J.1    Jaszczak, R.J.2    McCormick, J.W.3    Colemen, R.E.4    Lim, C.B.5
  • 3
    • 0033954645 scopus 로고    scopus 로고
    • Efficient correction for CT image artifacts caused by objects extending outside the scan field of view
    • B. Ohnesorge, T. Flohr, K. Schwarz, J. P. Heiken, and K. T. Bae, " Efficient correction for CT image artifacts caused by objects extending outside the scan field of view.," Med. Phys. 27 (1), 39-46 (2000).
    • (2000) Med. Phys. , vol.27 , Issue.1 , pp. 39-46
    • Ohnesorge, B.1    Flohr, T.2    Schwarz, K.3    Heiken, J.P.4    Bae, K.T.5
  • 4
    • 22844449456 scopus 로고    scopus 로고
    • Reconstruction from truncated projections in CT using adaptive detruncation
    • K. Sourbelle, M. Kachelrieß, and W. A. Kalender, " Reconstruction from truncated projections in CT using adaptive detruncation.," Eur. Radiol. 15 (5), 1008-1014 (2005).
    • (2005) Eur. Radiol. , vol.15 , Issue.5 , pp. 1008-1014
    • Sourbelle, K.1    Kachelrieß, M.2    Kalender, W.A.3
  • 5
    • 34247584689 scopus 로고    scopus 로고
    • Extension of the reconstruction field of view and truncation correction using sinogram decomposition
    • A. A. Zamyatin and N. Satoru, " Extension of the reconstruction field of view and truncation correction using sinogram decomposition.," Med. Phys. 34 (5), 1593-1605 (2007).
    • (2007) Med. Phys. , vol.34 , Issue.5 , pp. 1593-1605
    • Zamyatin, A.A.1    Satoru, N.2
  • 7
    • 0035996482 scopus 로고    scopus 로고
    • X-ray micro-CT with a displaced detector array
    • G. Wang, " X-ray micro-CT with a displaced detector array.," Med. Phys. 29, 1634-1636 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1634-1636
    • Wang, G.1
  • 8
    • 0142089320 scopus 로고    scopus 로고
    • X-ray micro-CT with a displaced detector array: Application to helical cone-beam reconstruction
    • V. Liu, N. R. Lariviere, and G. Wang, " X-ray micro-CT with a displaced detector array: Application to helical cone-beam reconstruction., " Med. Phys. 30 (10), 2758-2761 (2003).
    • (2003) Med. Phys. , vol.30 , Issue.10 , pp. 2758-2761
    • Liu, V.1    Lariviere, N.R.2    Wang, G.3
  • 9
    • 0020030616 scopus 로고
    • Optimal short scan convolution reconstruction for fan-beam CT
    • D. L. Parker, " Optimal short scan convolution reconstruction for fan-beam CT.," Med. Phys. 9 (2), 254-257 (1982).
    • (1982) Med. Phys. , vol.9 , Issue.2 , pp. 254-257
    • Parker, D.L.1
  • 10
    • 33745648523 scopus 로고    scopus 로고
    • Multi-threaded cardiac CT
    • M. Kachelrieß, M. Knaup, and W. A. Kalender, " Multi-threaded cardiac CT.," Med. Phys. 33 (7), 2435-2447 (2006).
    • (2006) Med. Phys. , vol.33 , Issue.7 , pp. 2435-2447
    • Kachelrieß, M.1    Knaup, M.2    Kalender, W.A.3
  • 12
    • 11244310646 scopus 로고    scopus 로고
    • Geometric misalignment and calibration in cone-beam tomography
    • L. von Smekal, M. Kachelrieß, E. Stepina, and W. A. Kalender, " Geometric misalignment and calibration in cone-beam tomography.," Med. Phys. 31 (12), 3242-3266 (2004).
    • (2004) Med. Phys. , vol.31 , Issue.12 , pp. 3242-3266
    • Von Smekal, L.1    Kachelrieß, M.2    Stepina, E.3    Kalender, W.A.4
  • 13
    • 34548299710 scopus 로고    scopus 로고
    • Empirical dual energy calibration (EDEC) for cone-beam computed tomography
    • P. Stenner, T. Berkus, and M. Kachelrieß, " Empirical dual energy calibration (EDEC) for cone-beam computed tomography.," Med. Phys. 34 (9), 3630-3641 (2007).
    • (2007) Med. Phys. , vol.34 , Issue.9 , pp. 3630-3641
    • Stenner, P.1    Berkus, T.2    Kachelrieß, M.3
  • 15
    • 29944432651 scopus 로고    scopus 로고
    • Reduction of half-scan shading artifact based on full-scan correction
    • J. Arbash Meinel, E. Hoffman, A. Clough, and G. Wang, " Reduction of half-scan shading artifact based on full-scan correction.," Acad. Radiol. 13 (1), 55-62 (2006).
    • (2006) Acad. Radiol. , vol.13 , Issue.1 , pp. 55-62
    • Arbash Meinel, J.1    Hoffman, E.2    Clough, A.3    Wang, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.