-
3
-
-
70350468989
-
-
Tsunamic Technologies Inc
-
Tsunamic Technologies Inc., Cluster computing on demand. http://www.clusterondemand.com/.
-
Cluster computing on demand
-
-
-
4
-
-
38449106208
-
Multithreaded tomographic reconstruction
-
Recent Advances in PVM and MPI, of, Paris, France, Sept/Oct
-
J. Alvarez, J. Roca, and J. Fernandez. Multithreaded tomographic reconstruction. In Recent Advances in PVM and MPI, volume 4757 of LNCS, pages 81-88, Paris, France, Sept/Oct 2007.
-
(2007)
LNCS
, vol.4757
, pp. 81-88
-
-
Alvarez, J.1
Roca, J.2
Fernandez, J.3
-
5
-
-
0028485175
-
On parallelizing the EM algorithm for PET image reconstruction
-
C. Chen and S. Lee. On parallelizing the EM algorithm for PET image reconstruction. IEEE Trans. Par. Distr. Sys., 5(8):860-873, 1994.
-
(1994)
IEEE Trans. Par. Distr. Sys
, vol.5
, Issue.8
, pp. 860-873
-
-
Chen, C.1
Lee, S.2
-
6
-
-
10744219626
-
SPMD cluster-based parallel 3-D OSEM
-
October
-
J. P. Jones, W. F. Jones, and F. Kehren. SPMD cluster-based parallel 3-D OSEM. IEEE Trans. Nuclear Sciences., 50(5): 1498-1502, October 2003.
-
(2003)
IEEE Trans. Nuclear Sciences
, vol.50
, Issue.5
, pp. 1498-1502
-
-
Jones, J.P.1
Jones, W.F.2
Kehren, F.3
-
7
-
-
34147110778
-
Hyperfast parallel-beam and cone-beam backprojection using the Cell general purpose hardware
-
M. Kachelrieß, M. Knaup, and O. Bockenbach. Hyperfast parallel-beam and cone-beam backprojection using the Cell general purpose hardware. Medical Physics, 34(4): 1474-1486, 2007.
-
(2007)
Medical Physics
, vol.34
, Issue.4
, pp. 1474-1486
-
-
Kachelrieß, M.1
Knaup, M.2
Bockenbach, O.3
-
9
-
-
84883305019
-
-
OpenMP Architecture Review Board
-
OpenMP Architecture Review Board. OpenMP specifications. http://www.openmp.org/specs.
-
OpenMP specifications
-
-
-
10
-
-
38649090106
-
Fully 3-d list-mode OSEM accelerated by graphics processing units
-
IEEE, October
-
G. Pratx, G. Chinn, F. Habte, P. Olcott, and C. Levin. Fully 3-d list-mode OSEM accelerated by graphics processing units. In IEEE Nuclear Science Symposium and Medical Imaging Conference Record, volume 4, pages 2196-2202. IEEE, October 2006.
-
(2006)
IEEE Nuclear Science Symposium and Medical Imaging Conference Record
, vol.4
, pp. 2196-2202
-
-
Pratx, G.1
Chinn, G.2
Habte, F.3
Olcott, P.4
Levin, C.5
-
11
-
-
0031961296
-
Fast accurate iterative reconstruction for low-statistics positron volume imaging
-
A. J. Reader, K. Erlandsson, M. A. Flower, and R. J. Ott. Fast accurate iterative reconstruction for low-statistics positron volume imaging. Phys. Med. Biol., 43(4):823-834, 1998.
-
(1998)
Phys. Med. Biol
, vol.43
, Issue.4
, pp. 823-834
-
-
Reader, A.J.1
Erlandsson, K.2
Flower, M.A.3
Ott, R.J.4
-
12
-
-
23044493588
-
Performance evaluation of the 32-module quadHIDAC small-animal PET scanner
-
K. P. Schäfers, A. J. Reader, M. Kriens, C. Knoess, O. Schober, and M. Schäfers. Performance evaluation of the 32-module quadHIDAC small-animal PET scanner. Journal Nucl. Med., 46(6):996-1004, 2005.
-
(2005)
Journal Nucl. Med
, vol.46
, Issue.6
, pp. 996-1004
-
-
Schäfers, K.P.1
Reader, A.J.2
Kriens, M.3
Knoess, C.4
Schober, O.5
Schäfers, M.6
-
13
-
-
48149109096
-
Towards a grid system for medical image reconstruction
-
IEEE, October
-
M. Schellmann, D. Bohm, S. Wichmann, and S. Gorlatch. Towards a grid system for medical image reconstruction. In IEEE Nuclear Science Symposium and Medical Imaging Conference Record, pages 3019-3025. IEEE, October 2007.
-
(2007)
IEEE Nuclear Science Symposium and Medical Imaging Conference Record
, pp. 3019-3025
-
-
Schellmann, M.1
Bohm, D.2
Wichmann, S.3
Gorlatch, S.4
-
14
-
-
48149098431
-
Comparison of two decomposition strategies for parallelizing the 3d list-mode OSEM algorithm
-
July
-
M. Schellmann and S. Gorlatch. Comparison of two decomposition strategies for parallelizing the 3d list-mode OSEM algorithm. In Proceedings Fully 3D Meeting and HPIR Workshop, pages 37-40, July 2007.
-
(2007)
Proceedings Fully 3D Meeting and HPIR Workshop
, pp. 37-40
-
-
Schellmann, M.1
Gorlatch, S.2
-
15
-
-
38649131360
-
Performance characteristics of the argus-drt small animal pet scanner: Preliminary results
-
IEEE, October
-
J. Vaquero, J. Pascau, A. Molins, J. Arco, and M. Desco. Performance characteristics of the argus-drt small animal pet scanner: preliminary results. In IEEE Nuclear Science Symposium and Medical Imaging Conference, Record. IEEE, October 2004.
-
(2004)
IEEE Nuclear Science Symposium and Medical Imaging Conference, Record
-
-
Vaquero, J.1
Pascau, J.2
Molins, A.3
Arco, J.4
Desco, M.5
-
16
-
-
29144473726
-
Speedup OS-EM image reconstruction by PC graphics card technologies for quantitative SPECT with varying focal-length fan-beam collimation
-
October
-
Z. Wang, G. Han, T. Li, and Z. Liang. Speedup OS-EM image reconstruction by PC graphics card technologies for quantitative SPECT with varying focal-length fan-beam collimation. IEEE Trans. on Nuclear Science, 52(5): 1274-1280, October 2005.
-
(2005)
IEEE Trans. on Nuclear Science
, vol.52
, Issue.5
, pp. 1274-1280
-
-
Wang, Z.1
Han, G.2
Li, T.3
Liang, Z.4
-
17
-
-
23844499125
-
Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware
-
June
-
F. Xu and K. Mueller. Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware. IEEE Trans. on Nuclear Science, 52(3):654-663, June 2005.
-
(2005)
IEEE Trans. on Nuclear Science
, vol.52
, Issue.3
, pp. 654-663
-
-
Xu, F.1
Mueller, K.2
|