메뉴 건너뛰기




Volumn 24, Issue 12, 2008, Pages 1430-1432

Suture Passing Needle Breakage During Arthroscopic Rotator Cuff Repair: A Complication Report

Author keywords

Arthroscopy; Broken needle; Complication; Suture passing device

Indexed keywords

ADULT; ARTHROGRAPHY; ARTHROSCOPIC SURGERY; ARTICLE; CASE REPORT; DECOMPRESSION SURGERY; EQUIPMENT; FEMALE; HUMAN; LIGAMENT SURGERY; NEEDLE; RANGE OF MOTION; SHOULDER ARTHROSCOPY; SHOULDER PAIN; SHOULDER RADIOGRAPHY; SURGICAL INSTRUMENT; SUTURE; TENDON INJURY;

EID: 56449128991     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2007.10.010     Document Type: Article
Times cited : (7)

References (5)
  • 1
    • 0024159688 scopus 로고
    • Complications in arthroscopic surgery performed by experienced arthroscopists
    • Small N.C. Complications in arthroscopic surgery performed by experienced arthroscopists. Arthroscopy 4 (1988) 215-221
    • (1988) Arthroscopy , vol.4 , pp. 215-221
    • Small, N.C.1
  • 2
    • 33750480211 scopus 로고    scopus 로고
    • An unusual cause of knee pain 10 years after arthroscopy
    • Rajadhyaksha A.D., Mont M.A., and Becker L. An unusual cause of knee pain 10 years after arthroscopy. Arthroscopy 22 (2006) 1253.e1-1253.e3
    • (2006) Arthroscopy , vol.22
    • Rajadhyaksha, A.D.1    Mont, M.A.2    Becker, L.3
  • 3
    • 20944437115 scopus 로고    scopus 로고
    • An unusual complication of knee arthroscopy: An extra-articular migrated asymptomatic broken probe from the knee joint
    • Oztekin H.H. An unusual complication of knee arthroscopy: An extra-articular migrated asymptomatic broken probe from the knee joint. Arch Orthop Trauma Surg 125 (2005) 285-287
    • (2005) Arch Orthop Trauma Surg , vol.125 , pp. 285-287
    • Oztekin, H.H.1
  • 4
    • 0242426714 scopus 로고    scopus 로고
    • Intra-articular foreign body after arthroscopy
    • Oldenburg M., and Mueller R. Intra-articular foreign body after arthroscopy. Arthroscopy 19 (2003) 1012-1014
    • (2003) Arthroscopy , vol.19 , pp. 1012-1014
    • Oldenburg, M.1    Mueller, R.2
  • 5
    • 0642307112 scopus 로고    scopus 로고
    • Detachment of the tip of a motorized shaver within the knee joint: a complication of arthroscopic surgery
    • In Y., Bahk W.J., and Park J.B. Detachment of the tip of a motorized shaver within the knee joint: a complication of arthroscopic surgery. Arthroscopy 19 (2003) e25-e27
    • (2003) Arthroscopy , vol.19
    • In, Y.1    Bahk, W.J.2    Park, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.