메뉴 건너뛰기




Volumn 8, Issue 11, 2008, Pages 7157-7171

Mercury determination in fish samples by chronopotentiometric stripping analysis using gold electrodes prepared from recordable CDs

Author keywords

Chronopotentiometric stripping analysis; Fish analysis; Fish digestion; Gold electrodes; Mercury analysis

Indexed keywords

ELECTROCHEMICAL BEHAVIORS; FISH ANALYSIS; FUMING NITRIC ACIDS; GOLD ELECTRODES; MERCURY ANALYSIS; MERCURY DETERMINATION; STRIPPING ANALYSIS; WORKING PARAMETERS;

EID: 56449088497     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s8117157     Document Type: Article
Times cited : (24)

References (34)
  • 1
    • 0031527339 scopus 로고    scopus 로고
    • Stripping voltammetry of copper and lead using gold electrodes modified with self-assembled monolayers
    • Shen, H.; Mark, J.E.; Seliskar, C.J.; Mark, Jr., H.B., Heineman, W.R. Stripping voltammetry of copper and lead using gold electrodes modified with self-assembled monolayers. J. Solid State Electrochem. 1997, 1, 241-247.
    • (1997) J. Solid State Electrochem , vol.1 , pp. 241-247
    • Shen, H.1    Mark, J.E.2    Seliskar, C.J.3    Mark Jr., H.B.4    Heineman, W.R.5
  • 2
    • 33747113659 scopus 로고    scopus 로고
    • Determination of Copper(II) by Anodic Stripping Voltammetry at a 2,5-Dimercapto-1,3,4-thiadiazol Self-assembled Monolayer-based Gold Electrode
    • Jiang, Y.N.; Luo, H.Q.; Li, N.B. Determination of Copper(II) by Anodic Stripping Voltammetry at a 2,5-Dimercapto-1,3,4-thiadiazol Self-assembled Monolayer-based Gold Electrode. Anal. Sci. 2006, 22, 1079-1083.
    • (2006) Anal. Sci , vol.22 , pp. 1079-1083
    • Jiang, Y.N.1    Luo, H.Q.2    Li, N.B.3
  • 3
    • 33244469462 scopus 로고    scopus 로고
    • Gold-based screen-printed sensor for detection of trace lead
    • Lasch, S.; Palchetti, I.; Mascini, M. Gold-based screen-printed sensor for detection of trace lead. Sens. Actuat. B: Chem. 2006, 114, 460-465.
    • (2006) Sens. Actuat. B: Chem , vol.114 , pp. 460-465
    • Lasch, S.1    Palchetti, I.2    Mascini, M.3
  • 4
    • 84987460611 scopus 로고
    • Determination of arsenic by stripping potentiometry on gold electrodes using partial least-squares (PLS) regression calibration
    • Jagner, D.; Renman, L.; Stefansqottir, S.H. Determination of arsenic by stripping potentiometry on gold electrodes using partial least-squares (PLS) regression calibration. Electroanalysis 1994, 6, 201-208.
    • (1994) Electroanalysis , vol.6 , pp. 201-208
    • Jagner, D.1    Renman, L.2    Stefansqottir, S.H.3
  • 5
    • 17444420325 scopus 로고    scopus 로고
    • Determination of As(III) and As(V) in oilseeds by chronopotentiometric stripping analysis: Development of a method
    • Svarc-Gajiic, J.V.; Suturoviic, Z.J.; Marjanovic, N.J.; Kravic, S.Z. Determination of As(III) and As(V) in oilseeds by chronopotentiometric stripping analysis: Development of a method.Molec. Nutr. Food Res. 2005, 49, 337-342.
    • (2005) Molec. Nutr. Food Res , vol.49 , pp. 337-342
    • Svarc-Gajiic, J.V.1    Suturoviic, Z.J.2    Marjanovic, N.J.3    Kravic, S.Z.4
  • 6
    • 0001198372 scopus 로고    scopus 로고
    • Self-assembled monolayers of 2-mercaptobenz imidazole on gold: Stripping voltammetric determination of Hg(II)
    • Berchmans, S.; Arivukkodi, S.; Yegnaraman, V. Self-assembled monolayers of 2-mercaptobenz imidazole on gold: stripping voltammetric determination of Hg(II). Electrochem. Commun. 2000, 2, 226-229.
    • (2000) Electrochem. Commun , vol.2 , pp. 226-229
    • Berchmans, S.1    Arivukkodi, S.2    Yegnaraman, V.3
  • 7
    • 20444457625 scopus 로고    scopus 로고
    • Mercury Detection in Seawater Using a Mercaptoacetic Acid Modified Gold Microwire Electrode
    • Widmann, A.; Van den Berg, C.M.G. Mercury Detection in Seawater Using a Mercaptoacetic Acid Modified Gold Microwire Electrode. Electroanalysis 2005, 17, 825-831.
    • (2005) Electroanalysis , vol.17 , pp. 825-831
    • Widmann, A.1    Van den Berg, C.M.G.2
  • 8
    • 0034623683 scopus 로고    scopus 로고
    • Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode
    • Bonfil, Y.; Brand, M.; Kirowa-Eisner, E. Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode. Anal. Chim. Acta 2000, 424, 65-76.
    • (2000) Anal. Chim. Acta , vol.424 , pp. 65-76
    • Bonfil, Y.1    Brand, M.2    Kirowa-Eisner, E.3
  • 9
    • 0032487388 scopus 로고    scopus 로고
    • Stripping voltammetric determination of mercury at modified solid electrodes: I. Development of the modified electrodes
    • Stojko, N.Y.; Brainina, K.Z.; Faller, C.; Henze, G. Stripping voltammetric determination of mercury at modified solid electrodes: I. Development of the modified electrodes. Anal. Chim. Acta 1998, 371, 145-153.
    • (1998) Anal. Chim. Acta , vol.371 , pp. 145-153
    • Stojko, N.Y.1    Brainina, K.Z.2    Faller, C.3    Henze, G.4
  • 10
    • 0032836277 scopus 로고    scopus 로고
    • Stripping voltammetric determination of mercury at modified solid electrodes: Determination of mercury traces using PDC/Au(III) modified electrodes
    • Stojko, N.Y.; Faller, C.; Henze, G.; Brainina, K.Z. Stripping voltammetric determination of mercury at modified solid electrodes: Determination of mercury traces using PDC/Au(III) modified electrodes. Anal. Chim. Acta 1999, 396, 195-202.
    • (1999) Anal. Chim. Acta , vol.396 , pp. 195-202
    • Stojko, N.Y.1    Faller, C.2    Henze, G.3    Brainina, K.Z.4
  • 11
    • 0001283362 scopus 로고    scopus 로고
    • Remote Electrochemical Sensor for Monitoring Trace Mercury
    • Wang, J.; Tian, B.; Lu, J.; Wang, J.; Luo, D.; MacDonald, D. Remote Electrochemical Sensor for Monitoring Trace Mercury. Electroanalysis 1998, 10, 399-402.
    • (1998) Electroanalysis , vol.10 , pp. 399-402
    • Wang, J.1    Tian, B.2    Lu, J.3    Wang, J.4    Luo, D.5    MacDonald, D.6
  • 12
    • 0027459255 scopus 로고
    • Screen-printed electrodes for stripping measurements of trace mercury
    • Wang, J.; Tian, B. Screen-printed electrodes for stripping measurements of trace mercury. Anal. Chim. Acta 1993, 274, 1-6.
    • (1993) Anal. Chim. Acta , vol.274 , pp. 1-6
    • Wang, J.1    Tian, B.2
  • 13
    • 0028066849 scopus 로고
    • Potentiometrie stripping determination of mercury(II), selenium(IV), copper(II) and lead(II) at a gold film electrode in water samples
    • Gill, E.P.; Ostapczuk, P. Potentiometrie stripping determination of mercury(II), selenium(IV), copper(II) and lead(II) at a gold film electrode in water samples. Anal. Chim. Acta 1994, 293, 55-65.
    • (1994) Anal. Chim. Acta , vol.293 , pp. 55-65
    • Gill, E.P.1    Ostapczuk, P.2
  • 14
    • 0010426311 scopus 로고
    • Voltammetric methods for determination of mercury in domestic waste and compost
    • Golimowski, J.; Orzechowska, A.; Tykarska, A. Voltammetric methods for determination of mercury in domestic waste and compost. Fresenius' J. Anal. Chem. 1995, 351, 656-659.
    • (1995) Fresenius' J. Anal. Chem , vol.351 , pp. 656-659
    • Golimowski, J.1    Orzechowska, A.2    Tykarska, A.3
  • 15
    • 0034003675 scopus 로고    scopus 로고
    • The use of a remote stripping sensor for the determination of copper and mercury in the Lagoon of Venice
    • Daniele, S.; Bragato, C.; Baldo, A.; Wang, J.; Lu, J. The use of a remote stripping sensor for the determination of copper and mercury in the Lagoon of Venice. Analyst 2000, 125, 731-735.
    • (2000) Analyst , vol.125 , pp. 731-735
    • Daniele, S.1    Bragato, C.2    Baldo, A.3    Wang, J.4    Lu, J.5
  • 16
    • 0346496335 scopus 로고    scopus 로고
    • Rapid Determination of Mercury in Water by Stripping Voltammetry at a Gold-Modified Carbon Electrode
    • Khutstenko, L.A.; Larina, L.N.; Nazarov, B.F. Rapid Determination of Mercury in Water by Stripping Voltammetry at a Gold-Modified Carbon Electrode. J. Anal. Chem. 2003, 58, 262- 267.
    • (2003) J. Anal. Chem , vol.58 , pp. 262-267
    • Khutstenko, L.A.1    Larina, L.N.2    Nazarov, B.F.3
  • 17
    • 20444476267 scopus 로고    scopus 로고
    • Chronopotentiometric Stripping Analysis Using Gold Electrodes, an Efficient Technique for Mercury Quantification in Natural Waters
    • Augelli, M.A.; Munoz, R.A.A.; Richter, E.M.; Junior, A.G.; Angnes, L. Chronopotentiometric Stripping Analysis Using Gold Electrodes, an Efficient Technique for Mercury Quantification in Natural Waters. Electroanalysis 2005, 17, 755-761.
    • (2005) Electroanalysis , vol.17 , pp. 755-761
    • Augelli, M.A.1    Munoz, R.A.A.2    Richter, E.M.3    Junior, A.G.4    Angnes, L.5
  • 18
    • 33745137128 scopus 로고    scopus 로고
    • Fast ultrasound-assisted treatment of urine samples for chronopotentiometric stripping determination of mercury at gold film electrodes
    • Munoz, R.A.A.; Felix, F.S.; Augelli, M.A.; Pavesi, T.; Angnes, L. Fast ultrasound-assisted treatment of urine samples for chronopotentiometric stripping determination of mercury at gold film electrodes. Anal. Chim. Acta 2006, 571, 93-98.
    • (2006) Anal. Chim. Acta , vol.571 , pp. 93-98
    • Munoz, R.A.A.1    Felix, F.S.2    Augelli, M.A.3    Pavesi, T.4    Angnes, L.5
  • 19
    • 33748460482 scopus 로고    scopus 로고
    • Analytical procedure for total mercury determination in fishes and shrimps by chronopotentiometric stripping analysis at gold film electrodes after microwave digestion
    • Augelli, M.A.; Munoz, R.A.A.; Richter, E.M.; Cantagallo, M.I.; Angnes, L. Analytical procedure for total mercury determination in fishes and shrimps by chronopotentiometric stripping analysis at gold film electrodes after microwave digestion. Food Chem. 2007, 101, 579-584.
    • (2007) Food Chem , vol.101 , pp. 579-584
    • Augelli, M.A.1    Munoz, R.A.A.2    Richter, E.M.3    Cantagallo, M.I.4    Angnes, L.5
  • 20
    • 0000808336 scopus 로고    scopus 로고
    • Gold electrodes from recordable CDs for mercury quantification by flow injection analysis
    • Richter, E.M.; Augelli, M.A.; Kume, G.H.; Mioshi, R.N.; Angnes, L. Gold electrodes from recordable CDs for mercury quantification by flow injection analysis. Fresenius' J. Anal. Chem. 2000, 366, 444 - 448.
    • (2000) Fresenius' J. Anal. Chem , vol.366 , pp. 444-448
    • Richter, E.M.1    Augelli, M.A.2    Kume, G.H.3    Mioshi, R.N.4    Angnes, L.5
  • 21
    • 0035980455 scopus 로고    scopus 로고
    • Gold electrodes from compact discs modified with platinum for amperometric determination of ascorbic acid in pharmaceutical formulations
    • Munoz, R.A.A.; Matos, R.C.; Angnes, L. Gold electrodes from compact discs modified with platinum for amperometric determination of ascorbic acid in pharmaceutical formulations. Talanta 2001, 55, 855-860.
    • (2001) Talanta , vol.55 , pp. 855-860
    • Munoz, R.A.A.1    Matos, R.C.2    Angnes, L.3
  • 22
    • 0035206069 scopus 로고    scopus 로고
    • Amperometric determination of dipyrone in pharmaceutical formulation with a flow cell containing gold electrode from recordable compact discs
    • Munoz, R.A.A.; Matos, R.C.; Angnes, L. Amperometric determination of dipyrone in pharmaceutical formulation with a flow cell containing gold electrode from recordable compact discs. J. Pharm. Sci. 2001, 90, 1972-1977.
    • (2001) J. Pharm. Sci , vol.90 , pp. 1972-1977
    • Munoz, R.A.A.1    Matos, R.C.2    Angnes, L.3
  • 23
    • 0037083688 scopus 로고    scopus 로고
    • Flow through cell for on-line amperometric determination of Ce(IV) during polymerization reactions
    • Westbroek, P.; De Strycher, J.; Dubruel, P.; Temmerman, E.; Schocht, E.H. Flow through cell for on-line amperometric determination of Ce(IV) during polymerization reactions. Anal. Chem. 2002, 74, 915-920.
    • (2002) Anal. Chem , vol.74 , pp. 915-920
    • Westbroek, P.1    De Strycher, J.2    Dubruel, P.3    Temmerman, E.4    Schocht, E.H.5
  • 24
    • 85159502037 scopus 로고    scopus 로고
    • Richter, E.M.; Fracassi da Silva, J.A.; Gutz, I.G.R.; do Lago, C.L.; Angnes, L. Disposable twin gold electrodes for amperometric detection in capillary electrophoresis. Electrophoresis 2004, 25, 2965-2969.
    • Richter, E.M.; Fracassi da Silva, J.A.; Gutz, I.G.R.; do Lago, C.L.; Angnes, L. Disposable twin gold electrodes for amperometric detection in capillary electrophoresis. Electrophoresis 2004, 25, 2965-2969.
  • 25
    • 30144434486 scopus 로고    scopus 로고
    • Combination of ultrasonic extraction and stripping analysis: An effective and reliable way for the determination of Cu and Pb in lubricating oils
    • Munoz, R.A.A.; Oliveira, P.V.; Angnes, L. Combination of ultrasonic extraction and stripping analysis: An effective and reliable way for the determination of Cu and Pb in lubricating oils. Talanta 2006, 68, 850-856.
    • (2006) Talanta , vol.68 , pp. 850-856
    • Munoz, R.A.A.1    Oliveira, P.V.2    Angnes, L.3
  • 26
    • 0034961041 scopus 로고    scopus 로고
    • Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA
    • Richter, E.M.; Augelli, M.A.; Magarotto, S.; Angnes, L. Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA. Electroanalysis 2001, 13, 760-764.
    • (2001) Electroanalysis , vol.13 , pp. 760-764
    • Richter, E.M.1    Augelli, M.A.2    Magarotto, S.3    Angnes, L.4
  • 27
    • 0042190281 scopus 로고    scopus 로고
    • Quick production of gold electrode sets or arrays and of microfluidic flow cells based on heat transfer of laser printed toner masks onto compact discs
    • Daniel, D.; Gutz, I.G.R. Quick production of gold electrode sets or arrays and of microfluidic flow cells based on heat transfer of laser printed toner masks onto compact discs. Electrochem. Comm. 2003, 5, 782-786.
    • (2003) Electrochem. Comm , vol.5 , pp. 782-786
    • Daniel, D.1    Gutz, I.G.R.2
  • 29
    • 84886759807 scopus 로고    scopus 로고
    • www.kodak.com.
  • 30
    • 19744367719 scopus 로고    scopus 로고
    • Determination of inorganic and total mercury by vapor generation atomic absorption spectrometry using different temperatures of the measurement cell
    • Kaercher, L.E.; Goldschmidt, F.; Paniz, J. N. G.; de Moraes Flores, E. M.; Dressler, V. L. Determination of inorganic and total mercury by vapor generation atomic absorption spectrometry using different temperatures of the measurement cell. Spectrochim. Acta. Part B 2005, 60, 705-710.
    • (2005) Spectrochim. Acta. Part B , vol.60 , pp. 705-710
    • Kaercher, L.E.1    Goldschmidt, F.2    Paniz, J.N.G.3    de Moraes Flores, E.M.4    Dressler, V.L.5
  • 31
    • 0033833417 scopus 로고    scopus 로고
    • Methylmercury and inorganic mercury determination in fish by cold vapour generation atomic absorption spectrometry
    • Ubillus, F.; Alegria, A.; Barebera, R.; Farre, R.; Lagarda, M.J. Methylmercury and inorganic mercury determination in fish by cold vapour generation atomic absorption spectrometry. Food Chem. 2000, 71, 529-533.
    • (2000) Food Chem , vol.71 , pp. 529-533
    • Ubillus, F.1    Alegria, A.2    Barebera, R.3    Farre, R.4    Lagarda, M.J.5
  • 32
    • 84876639890 scopus 로고    scopus 로고
    • Danet, A.F. In Electrochemical Analysis Methods; Scientific Publishing: Bucharest, Romania, 1996; p. 225.
    • Danet, A.F. In Electrochemical Analysis Methods; Scientific Publishing: Bucharest, Romania, 1996; p. 225.
  • 33
    • 0021013816 scopus 로고
    • Determination of total mercury in fish: An improved method
    • Louie, H.W. Determination of total mercury in fish: an improved method. Analyst 1983, 108, 1313-1317.
    • (1983) Analyst , vol.108 , pp. 1313-1317
    • Louie, H.W.1
  • 34
    • 35448936872 scopus 로고    scopus 로고
    • Determination of Mercury in Fish Tissue Using a Minianalyzer Based on Cold Vapor Atomic Absorption Spectrometry at the 184.9 nm Line
    • Rizea, M.C.; Bratu, M.C.; Danet, A.F., Bratu, A. Determination of Mercury in Fish Tissue Using a Minianalyzer Based on Cold Vapor Atomic Absorption Spectrometry at the 184.9 nm Line. Anal. Sci. 2001, 23, 1121-1125.
    • (2001) Anal. Sci , vol.23 , pp. 1121-1125
    • Rizea, M.C.1    Bratu, M.C.2    Danet, A.F.3    Bratu, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.