메뉴 건너뛰기




Volumn 5370 III, Issue , 2004, Pages 1709-1719

Consistent interactive segmentation of pulmonary ground glass nodules identified in CT studies

Author keywords

CAD; Ground glass nodule (GGN); Markov random field (MRF); Nodule segmentation; Subsolid nodule

Indexed keywords

GROUND GLASS NODULES (GGN); MARKOV RANDOM FIELD (MRF); NODULE SEGMENTATION; SUBSOLID NODULE;

EID: 5644291974     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.536259     Document Type: Conference Paper
Times cited : (16)

References (9)
  • 1
    • 15844376071 scopus 로고    scopus 로고
    • Bronchioloalveolar carcinoma: Focal area of ground-glass attenuation at thin-section CT as an early sign
    • Hyun-Jung Jang, Kyung Soo Lee, O. Jung Kwon, Chong H. Rhee, Young Mog Shim, Jungho Han, "Bronchioloalveolar carcinoma: focal area of ground-glass attenuation at thin-section CT as an early sign", Radiology, vol. 199, pp. 485-488, 1996.
    • (1996) Radiology , vol.199 , pp. 485-488
    • Jang, H.-J.1    Kyung Soo Lee2    Jung Kwon, O.3    Rhee, C.H.4    Young Mog Shim5    Han, J.6
  • 4
    • 0036205004 scopus 로고    scopus 로고
    • Results of wedge resection for focal bronchioloalveolar carcinoma showing pure ground-glass attenuation on computed tomography
    • Shun-ichi Watanabe, Toshio Watanabe, Kazunori Arai, Takahiko Kasai, Joji Haratake, Hiroshi Urayama, "Results of wedge resection for focal bronchioloalveolar carcinoma showing pure ground-glass attenuation on computed tomography", Ann. Thorac. Surg., vol. 73, pp. 1071-1075, 2002.
    • (2002) Ann. Thorac. Surg. , vol.73 , pp. 1071-1075
    • Watanabe, S.-I.1    Watanabe, T.2    Arai, K.3    Kasai, T.4    Haratake, J.5    Urayama, H.6
  • 6
    • 0042922542 scopus 로고    scopus 로고
    • A detection method of ground glass opacities in chest X-ray CT images using automatic clustering techniques
    • Milan Sonka, J. Michael Fitzpatrick, Medical Imaging, San Diego
    • Mitsuhiro Tanino, Hotaka Takizawa, Shinji Yamamoto, Tohru Matsumoto, Yukio Tateno, Takeshi linuma, "A detection method of ground glass opacities in chest X-ray CT images using automatic clustering techniques", Proceedings of SPIE, Milan Sonka, J. Michael Fitzpatrick, vol. 5032, pp. 1728-1737, Medical Imaging 2003, San Diego.
    • (2003) Proceedings of SPIE , vol.5032 , pp. 1728-1737
    • Tanino, M.1    Takizawa, H.2    Yamamoto, S.3    Matsumoto, T.4    Tateno, Y.5    Linuma, T.6
  • 8
    • 0031283419 scopus 로고    scopus 로고
    • Volumetric object reconstruction using the 3D-MRF model-based segmentation
    • Soo Mi Choi, Jae Eun Lee, Jongwon Kim, Myoung Hee Kim, "Volumetric object reconstruction using the 3D-MRF model-based segmentation", IEEE Transactions on Medical Imaging, vol. 16, no. 6, pp. 887-892, 1997.
    • (1997) IEEE Transactions on Medical Imaging , vol.16 , Issue.6 , pp. 887-892
    • Soo Mi Choi1    Jae Eun Lee2    Kim, J.3    Myoung Hee Kim4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.