메뉴 건너뛰기




Volumn 5370 I, Issue , 2004, Pages 10-21

A system for automatic detection of lung nodules exhibiting growth

Author keywords

Computed tomography; Computer aided diagnosis (CAD); Lung nodule; Screening

Indexed keywords

COMPUTER AIDED DIAGNOSIS; COMPUTERIZED TOMOGRAPHY; ERRORS; EXTRAPOLATION; IMAGE SEGMENTATION; RADIOLOGY; SCREENING; TUMORS; VOLUMETRIC ANALYSIS;

EID: 5644283633     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.535389     Document Type: Conference Paper
Times cited : (8)

References (28)
  • 2
    • 0035467993 scopus 로고    scopus 로고
    • Global cancer statistics in the year 2000
    • Parkin DM, "Global cancer statistics in the year 2000", Lancet Oncol 2(9): 533-43, 2001.
    • (2001) Lancet Oncol , vol.2 , Issue.9 , pp. 533-543
    • Parkin, D.M.1
  • 4
    • 0036620245 scopus 로고    scopus 로고
    • Diagnosis and management of early lung cancer
    • Park BJ, Altorki NK, "Diagnosis and management of early lung cancer", Surg Clin North Am 82(3): 457-76, 2002.
    • (2002) Surg Clin North Am , vol.82 , Issue.3 , pp. 457-476
    • Park, B.J.1    Altorki, N.K.2
  • 6
    • 0141997086 scopus 로고    scopus 로고
    • Surgery for early stage non-small cell lung cancer
    • Chang MY, Sugarbaker DJ, "Surgery for early stage non-small cell lung cancer", Semin Surg Oncol 21(2): 74-84, 2003.
    • (2003) Semin Surg Oncol , vol.21 , Issue.2 , pp. 74-84
    • Chang, M.Y.1    Sugarbaker, D.J.2
  • 8
    • 0141841669 scopus 로고    scopus 로고
    • Detection of pulmonary nodules by multislice computed tomography: Improved detection rate with reduced slice thickness
    • Fischbach F, Knollmann F, Griesshaber V, Freund T, Akkol E, Felix R, "Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness", Eur Radiol 13(10): 2378-83, 2003.
    • (2003) Eur Radiol , vol.13 , Issue.10 , pp. 2378-2383
    • Fischbach, F.1    Knollmann, F.2    Griesshaber, V.3    Freund, T.4    Akkol, E.5    Felix, R.6
  • 9
    • 0036028244 scopus 로고    scopus 로고
    • Inter-observer variations on interpretation of multi-slice CT lung cancer screening studies, and the implications for computer-aided diagnosis
    • Medical Imaging 2002; DP Chakraborty and EA Krupinski, editors
    • Novak CL, Qian J, Fan L, Ko JP, Rubinowitz AN, McGuinness G, Naidich DP, "Inter-observer variations on interpretation of multi-slice CT lung cancer screening studies, and the implications for computer-aided diagnosis", Medical Imaging 2002; DP Chakraborty and EA Krupinski, editors; Proceedings of SPIE 4686: 68-79, 2002.
    • (2002) Proceedings of SPIE , vol.4686 , pp. 68-79
    • Novak, C.L.1    Qian, J.2    Fan, L.3    Ko, J.P.4    Rubinowitz, A.N.5    McGuinness, G.6    Naidich, D.P.7
  • 10
    • 0036891913 scopus 로고    scopus 로고
    • Lung cancer: Performance of automated lung nodule detection applied to cancers missed in a CT screening program
    • Armato SG, Li F, Giger ML, MacMahon H, Sone S, Doi K, "Lung cancer: performance of automated lung nodule detection applied to cancers missed in a CT screening program", Radiology 225(3): 685-92, 2002.
    • (2002) Radiology , vol.225 , Issue.3 , pp. 685-692
    • Armato, S.G.1    Li, F.2    Giger, M.L.3    MacMahon, H.4    Sone, S.5    Doi, K.6
  • 15
    • 0037260266 scopus 로고    scopus 로고
    • Lung micronodules: Automated method for detection at thin-section CT - Initial experience
    • Brown MS, Goldin JG, Sun RD, McNitt-Gray MF, Sayre JW, Aberle DR, "Lung micronodules: automated method for detection at thin-section CT - initial experience", Radiology 226(1): 256-62, 2003.
    • (2003) Radiology , vol.226 , Issue.1 , pp. 256-262
    • Brown, M.S.1    Goldin, J.G.2    Sun, R.D.3    McNitt-Gray, M.F.4    Sayre, J.W.5    Aberle, D.R.6
  • 16
    • 0036582337 scopus 로고    scopus 로고
    • Automatic detection of pulmonary nodules at spiral CT: Clinical application of a computer-aided diagnosis system
    • Wormanns D, Fiebich M, Saidi M, Diederich S, Heindel W, "Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system", Eur Radiol 12(5): 1052-7, 2002.
    • (2002) Eur Radiol , vol.12 , Issue.5 , pp. 1052-1057
    • Wormanns, D.1    Fiebich, M.2    Saidi, M.3    Diederich, S.4    Heindel, W.5
  • 17
    • 0036851688 scopus 로고    scopus 로고
    • Lung nodule detection on thoracic computed tomography images: Preliminary evaluation of a computer-aided diagnosis system
    • Gurcan MN, Sahiner B, Petrick N, Chan HP, Kazerooni EA, Cascade PN, Hadjiiski L, "Lung nodule detection on thoracic computed tomography images: preliminary evaluation of a computer-aided diagnosis system", Med Phys 29(11): 2552-8, 2002.
    • (2002) Med Phys , vol.29 , Issue.11 , pp. 2552-2558
    • Gurcan, M.N.1    Sahiner, B.2    Petrick, N.3    Chan, H.P.4    Kazerooni, E.A.5    Cascade, P.N.6    Hadjiiski, L.7
  • 19
    • 0036030550 scopus 로고    scopus 로고
    • Automatic detection method of lung cancers including ground-glass opacities from chest X-ray CT images
    • Medical Imaging 2002; M Sonka and MJ Fitzpatrick, editors
    • Ezoe T, Takizawa H, Yamamoto S, Shimizu A, Matsumoto T, Tateno Y, Iimura T, Matsumoto M, "Automatic detection method of lung cancers including ground-glass opacities from chest X-ray CT images", Medical Imaging 2002; M Sonka and MJ Fitzpatrick, editors; Proceedings of SPIE 4684: 1672-80, 2002.
    • (2002) Proceedings of SPIE , vol.4684 , pp. 1672-1680
    • Ezoe, T.1    Takizawa, H.2    Yamamoto, S.3    Shimizu, A.4    Matsumoto, T.5    Tateno, Y.6    Iimura, T.7    Matsumoto, M.8
  • 20
    • 0036032283 scopus 로고    scopus 로고
    • Computer aided lung nodule detection on high resolution CT data
    • Medical Imaging 2002; M Sonka and MJ Fitzpatrick, editors
    • Wiemker R, Rogalla P, Zwartkruis A, Blaffert T, "Computer aided lung nodule detection on high resolution CT data", Medical Imaging 2002; M Sonka and MJ Fitzpatrick, editors; Proceedings of SPIE 4684: 677-88, 2002.
    • (2002) Proceedings of SPIE , vol.4684 , pp. 677-688
    • Wiemker, R.1    Rogalla, P.2    Zwartkruis, A.3    Blaffert, T.4
  • 22
    • 0035134661 scopus 로고    scopus 로고
    • Chest CT: Automated nodule detection and assessment of change over time - Preliminary experience
    • Ko JP, Betke M, "Chest CT: automated nodule detection and assessment of change over time - preliminary experience", Radiology 218: 267-273, 2001.
    • (2001) Radiology , vol.218 , pp. 267-273
    • Ko, J.P.1    Betke, M.2
  • 23
    • 0034848895 scopus 로고    scopus 로고
    • Automatic detection of lung nodules from multi-slice low-dose CT images
    • Medical Imaging 2001; M Sonka and KM Hanson, editors
    • Fan L, Novak CL, Qian J, Kohl G, Naidich DP, "Automatic detection of lung nodules from multi-slice low-dose CT images", Medical Imaging 2001; M Sonka and KM Hanson, editors; Proceedings of SPIE 4322: 1828-1835, 2001.
    • (2001) Proceedings of SPIE , vol.4322 , pp. 1828-1835
    • Fan, L.1    Novak, C.L.2    Qian, J.3    Kohl, G.4    Naidich, D.P.5
  • 24
    • 84974738141 scopus 로고    scopus 로고
    • Automatic detection of nodules attached to vessels in lung CT by volume projection analysis
    • Fifth International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI), T Dohi and R Kikinis, editors
    • Wei G, Fan L, Qian J, "Automatic detection of nodules attached to vessels in lung CT by volume projection analysis", Fifth International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI), T Dohi and R Kikinis, editors, MICCAI Proceedings 2488: 746-752, 2002.
    • (2002) MICCAI Proceedings , vol.2488 , pp. 746-752
    • Wei, G.1    Fan, L.2    Qian, J.3
  • 25
    • 0042860042 scopus 로고    scopus 로고
    • Identification of missed pulmonary nodules on low dose CT lung cancer screening studies using an automatic detection system
    • Medical Imaging 2003; DP Chakraborty and EA Krupinski, editors
    • Novak CL, Fan L, Qian J, Wei G, Naidich DP, "Identification of missed pulmonary nodules on low dose CT lung cancer screening studies using an automatic detection system" Medical Imaging 2003; DP Chakraborty and EA Krupinski, editors; Proceedings of SPIE 5034:439-447, 2003.
    • (2003) Proceedings of SPIE , vol.5034 , pp. 439-447
    • Novak, C.L.1    Fan, L.2    Qian, J.3    Wei, G.4    Naidich, D.P.5
  • 26
    • 5644291220 scopus 로고    scopus 로고
    • Real-time and automatic matching of pulmonary nodules in follow-up multi-slice CT studies
    • International Conference on Diagnostic Imaging and Analysis (ICDIA), J Qian, S. Schaller, S Zhang editors
    • Shen H, Fan L, Qian J, Odry BL, Novak CL, Naidich DP, "Real-time and automatic matching of pulmonary nodules in follow-up multi-slice CT studies", International Conference on Diagnostic Imaging and Analysis (ICDIA), J Qian, S. Schaller, S Zhang editors, Proceedings of the ICDIA, 2002.
    • (2002) Proceedings of the ICDIA
    • Shen, H.1    Fan, L.2    Qian, J.3    Odry, B.L.4    Novak, C.L.5    Naidich, D.P.6
  • 27
    • 0036031026 scopus 로고    scopus 로고
    • Automatic segmentation of pulmonary nodules by using dynamic 3D cross-correlation for interactive CAD systems
    • Medical Imaging 2002; M Sonka and MJ Fitzpatrick, editors
    • Fan L, Qian J, Odry BL, Shen H, Naidich DP, Kohl G, Klotz E, "Automatic segmentation of pulmonary nodules by using dynamic 3D cross-correlation for interactive CAD systems", Medical Imaging 2002; M Sonka and MJ Fitzpatrick, editors; Proceedings of SPIE 4684: 1362-9, 2002.
    • (2002) Proceedings of SPIE , vol.4684 , pp. 1362-1369
    • Fan, L.1    Qian, J.2    Odry, B.L.3    Shen, H.4    Naidich, D.P.5    Kohl, G.6    Klotz, E.7
  • 28
    • 5644256180 scopus 로고    scopus 로고
    • ICAD: An interactive CAD system improving radiologists' interpretation of low-dose multi-slice lung CT studies
    • International Conference on Diagnostic Imaging and Analysis (ICDIA), J Qian, S. Schaller, S Zhang editors
    • Qian J, Fan L, Novak CL, Wei G, Odry BL, Naidich DP, Ko JP, Rubinowitz AN, McGuinness G, "ICAD: An interactive CAD system improving radiologists' interpretation of low-dose multi-slice lung CT studies", International Conference on Diagnostic Imaging and Analysis (ICDIA), J Qian, S. Schaller, S Zhang editors, Proceedings of the ICDIA, 2002.
    • (2002) Proceedings of the ICDIA
    • Qian, J.1    Fan, L.2    Novak, C.L.3    Wei, G.4    Odry, B.L.5    Naidich, D.P.6    Ko, J.P.7    Rubinowitz, A.N.8    McGuinness, G.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.