메뉴 건너뛰기




Volumn 5370 III, Issue , 2004, Pages 1932-1942

Automatic gating window positioning for 3D rotational coronary angiography (3DRCA)

Author keywords

3D rotational coronary angiography (3DRCA); Cardiac imaging; Optimal gating window position

Indexed keywords

BLOOD VESSELS; CARDIOVASCULAR SYSTEM; ELECTROCARDIOGRAPHY; IMAGE QUALITY; PATIENT TREATMENT; X RAY ANALYSIS;

EID: 5644241850     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.535481     Document Type: Conference Paper
Times cited : (2)

References (22)
  • 1
    • 0345633594 scopus 로고    scopus 로고
    • Three-dimensional reconstruction of high-contrast objects using c-arm image intensifier projection data
    • M. Grass, R. Koppe, and et al., "Three-dimensional reconstruction of high-contrast objects using c-arm image intensifier projection data," Comp Med Imag and Graphics 23, pp. 311 - 321, 1999.
    • (1999) Comp Med Imag and Graphics , vol.23 , pp. 311-321
    • Grass, M.1    Koppe, R.2
  • 3
    • 0035191083 scopus 로고    scopus 로고
    • Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using c-arm systems: Initial results
    • M. El-Sheik, J. T. Heverhagen, and et al., "Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using c-arm systems: initial results," Radiology 221, pp. 843 - 849, 2001.
    • (2001) Radiology , vol.221 , pp. 843-849
    • El-Sheik, M.1    Heverhagen, J.T.2
  • 4
    • 5644227059 scopus 로고    scopus 로고
    • 3d rotational angiography: Clinical value in endovascular treatment
    • J. M. et al., "3d rotational angiography: Clinical value in endovascular treatment," Medicamundi 42, 1998.
    • (1998) Medicamundi , vol.42
    • M., J.1
  • 7
    • 5644226205 scopus 로고    scopus 로고
    • 3d coronary reconstruction from calibrated motion-compensated 2d projections based on semi-automated feature point detection
    • p. in press, (Newport Beach, CA)
    • B. Movassaghi, V. Rasche, M. A. Viergever, and W. J. Niessen, "3d coronary reconstruction from calibrated motion-compensated 2d projections based on semi-automated feature point detection," in Proc. SPIE Medical Imaging: Image Processing, p. in press, (Newport Beach, CA), 2004.
    • (2004) Proc. SPIE Medical Imaging: Image Processing
    • Movassaghi, B.1    Rasche, V.2    Viergever, M.A.3    Niessen, W.J.4
  • 8
    • 0041419402 scopus 로고    scopus 로고
    • 3d vessel axis extraction using 2d calibrated x-ray projections for coronary modeling
    • (Newport Beach, CA)
    • S. Young, B. Movassaghi, J. Weese, and V. Rasche, "3d vessel axis extraction using 2d calibrated x-ray projections for coronary modeling," in Proc. SPIE Medical Imaging: Image Processing, 5032, pp. 1491-1498, (Newport Beach, CA), 2003.
    • (2003) Proc. SPIE Medical Imaging: Image Processing , vol.5032 , pp. 1491-1498
    • Young, S.1    Movassaghi, B.2    Weese, J.3    Rasche, V.4
  • 10
    • 5644221075 scopus 로고    scopus 로고
    • An accurate coronary modeling procedure using 2d calibrated projections based on extracted 3d vessel centerlines
    • Elsevier
    • B. Movassaghi, S. Young, and V. Rasche, "An accurate coronary modeling procedure using 2d calibrated projections based on extracted 3d vessel centerlines," in Computer Assisted Radiology and Surgery (CARS 2003), p. 1397, Elsevier, 2003.
    • (2003) Computer Assisted Radiology and Surgery (CARS 2003) , pp. 1397
    • Movassaghi, B.1    Young, S.2    Rasche, V.3
  • 13
    • 84958154884 scopus 로고    scopus 로고
    • 3d+t modeling of coronary artery tree from standard non simultaneous angiograms
    • F. Mourgues, F. Devernay, G. Malandain, and E. Coste-Manière, "3d+t modeling of coronary artery tree from standard non simultaneous angiograms," MICCAI '98, pp. 1320-1321, 2001.
    • (2001) MICCAI '98 , pp. 1320-1321
    • Mourgues, F.1    Devernay, F.2    Malandain, G.3    Coste-Manière, E.4
  • 14
    • 0028396008 scopus 로고
    • Reconstructing the 3-d medial axes of coronary arteries in single-view cine-angiograms
    • T. V. Nguyen and J. Sklansky, "Reconstructing the 3-d medial axes of coronary arteries in single-view cine-angiograms," IEEE Trans. Med. Imag. 13, pp. 61 - 73, 1994.
    • (1994) IEEE Trans. Med. Imag. , vol.13 , pp. 61-73
    • Nguyen, T.V.1    Sklansky, J.2
  • 15
    • 0034164339 scopus 로고    scopus 로고
    • 3-d reconstruction of coronary arterial tree to optimize angiographic visualization
    • S.-Y. J. Chen and J. D. Carroll, "3-d reconstruction of coronary arterial tree to optimize angiographic visualization," IEEE Trans. Med. Imag. 19(4), pp. 318 - 336, 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , Issue.4 , pp. 318-336
    • Chen, S.-Y.J.1    Carroll, J.D.2
  • 16
    • 0041538745 scopus 로고    scopus 로고
    • Ecg-gated 3d rotational coronary angiography
    • 83rd Scientific Session
    • V. Rasche, A. Buecker, M. Grass, R. Suurmond, R. Koppe., and H. Kuehl, "Ecg-gated 3d rotational coronary angiography," in RSNA, pp. C19-382, 83rd Scientific Session, 2003.
    • (2003) RSNA
    • Rasche, V.1    Buecker, A.2    Grass, M.3    Suurmond, R.4    Koppe, R.5    Kuehl, H.6
  • 18
    • 0034867726 scopus 로고    scopus 로고
    • Ecggated reconstructed multi-detector row ct coronary angiography: Effect of varying trigger delay on image quality
    • C. Hong, C. R. Becker, A. Huber, U. J. Schoepf, B. Ohnesorge, A. Knez, R. Bruning, and M. F. Reiser, "Ecggated reconstructed multi-detector row ct coronary angiography: effect of varying trigger delay on image quality," Radiology 220(3), pp. 712-717, 2001.
    • (2001) Radiology , vol.220 , Issue.3 , pp. 712-717
    • Hong, C.1    Becker, C.R.2    Huber, A.3    Schoepf, U.J.4    Ohnesorge, B.5    Knez, A.6    Bruning, R.7    Reiser, M.F.8
  • 19
    • 0032719272 scopus 로고    scopus 로고
    • Cardiac motion of coronary arteries: Variability in the rest period and implications for coronary mr angiography
    • Y. Wang, E. Vidan, and G. Bergman, "Cardiac motion of coronary arteries: variability in the rest period and implications for coronary mr angiography," Radiology 213(3), pp. 751-758, 1999.
    • (1999) Radiology , vol.213 , Issue.3 , pp. 751-758
    • Wang, Y.1    Vidan, E.2    Bergman, G.3
  • 20
    • 0035025219 scopus 로고    scopus 로고
    • Coronary artery motion during the cardiac cycle and optimal ecg triggering for coronary artery imaging
    • B. Lu, S. Mao, N. Zhuang, H. Bakhsheshi, H. Yamamoto, J. Takasu, S. Liu, and M. Budoff, "Coronary artery motion during the cardiac cycle and optimal ecg triggering for coronary artery imaging," Invest. Radial. 36(5), pp. 250-256, 2001.
    • (2001) Invest. Radial. , vol.36 , Issue.5 , pp. 250-256
    • Lu, B.1    Mao, S.2    Zhuang, N.3    Bakhsheshi, H.4    Yamamoto, H.5    Takasu, J.6    Liu, S.7    Budoff, M.8
  • 21
    • 0026254052 scopus 로고
    • Knowledge-based system for the three-dimensional reconstruction of blood vessels from two angiographie projections
    • C. Smets, F. van de Werf, P. Suetens, and A. Oosterlinck, "Knowledge-based system for the three-dimensional reconstruction of blood vessels from two angiographie projections," Med. Biol. Eng. Comp. 29, pp. NS27 - 36, 1991.
    • (1991) Med. Biol. Eng. Comp. , vol.29
    • Smets, C.1    Van De Werf, F.2    Suetens, P.3    Oosterlinck, A.4
  • 22
    • 0023224633 scopus 로고
    • Three-dimensional reconstruction of moving arterial beds from digital subtraction angiography
    • D. Parker, D. Pope, R. V. Bree, and H. Marshall, "Three-dimensional reconstruction of moving arterial beds from digital subtraction angiography," Comp. and Biomed. Res. 20, pp. 166 - 185, 1987.
    • (1987) Comp. and Biomed. Res. , vol.20 , pp. 166-185
    • Parker, D.1    Pope, D.2    Bree, R.V.3    Marshall, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.